Wiki source code of 3 Software
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | = **PIStudio Release Build VER:R05R998_V8.2.62_D20220625** = | ||
2 | |||
3 | (% class="wikigeneratedid" %) | ||
4 | **Official Website:** | ||
5 | |||
6 | (% class="wikigeneratedid" %) | ||
7 | **[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20220625.zip]]** | ||
8 | |||
9 | **Google Drive:** | ||
10 | |||
11 | **[[Download Link>>https://drive.google.com/file/d/1kJuuzxjPj5mZmeazhGxrs3lGyMceqmYj/view?usp=sharing]]** | ||
12 | |||
13 | == **Bugs Fixed** == | ||
14 | |||
15 | === **PC Software** === | ||
16 | |||
17 | A) Cloud.xml does not exist in the project file of 8000 series and cannot access cloud; | ||
18 | |||
19 | B) Lua prompting error when double click the project path of General series in Screen Management; | ||
20 | |||
21 | C) The cursor moving into the area of background script will be disappeared; | ||
22 | |||
23 | D) After the Lua script is changed, it is not compiled, and there is no prompt when clicking offline simulation; | ||
24 | |||
25 | E) DLView fails to import excel files; | ||
26 | |||
27 | F) There is an abnormality when creating image files into Udisk; | ||
28 | |||
29 | G) Orientation options missing for Slide switch; | ||
30 | |||
31 | H) COM3 Configuration missing for following models: 3070i-A and 3102i-A; | ||
32 | |||
33 | I) When the download tool downloads the project, it does not prompt when the file does not exist; | ||
34 | |||
35 | J) SD Card option missing for following models: 3070i-A, 3102i-A, 3070i-C, 3102i-C; | ||
36 | |||
37 | K) Some of the same font size, font style is different when the font size is displayed abnormally; | ||
38 | |||
39 | L) Optimize the built-in screen No.1008, add Time and Date objects; | ||
40 | |||
41 | M) Optimize the remote download; | ||
42 | |||
43 | N) Optimize the U disk upgrade function; | ||
44 | |||
45 | O) Prompt when the downloads a file with a long path; | ||
46 | |||
47 | P) The ig series vertical screen option is available now; | ||
48 | |||
49 | === **HMI Application** === | ||
50 | |||
51 | A) The i series freezes with HSW24 soft reboot; | ||
52 | |||
53 | B) Debugging window cannot be closed on the ig monitoring page; | ||
54 | |||
55 | C) Abnormal record time of ig Data record; | ||
56 | |||
57 | D) The ig series abnormal ethernet communication; | ||
58 | |||
59 | E)The register for network status HSW850 abnormal value; | ||
60 | |||
61 | F) Lua we_bas_getstring script function execution error; | ||
62 | |||
63 | G)The video title with English brackets cannot be played; | ||
64 | |||
65 | H)Touch screen will lead to HMI freezes when keyboard input and cursor is enabled; | ||
66 | |||
67 | I) Logo failed download for PI8150ig (before the firmware version 0313); | ||
68 | |||
69 | J) After PI8000 series remote download PLC program, PLC cannot communicate; | ||
70 | |||
71 | L) PI8000 series and ig series online V-NET but cannot remote control; | ||
72 | |||
73 | M) Background Ethernet static IP configuration is not saved; | ||
74 | |||
75 | N) The ig series WVPN remote pass through fails; | ||
76 | |||
77 | O)Lua timer does not perform timing operations according to the interval; | ||
78 | |||
79 | === **Driver Protocol** === | ||
80 | |||
81 | A) PI8000ig and Yudian sensor cannot communicate; | ||
82 | |||
83 | B) Modify the name of the Wecon LX6V protocol, the old version project must be re-selected; | ||
84 | |||
85 | C)The following serial port protocols have intermittent communication timeout issue: Siemens S7-200 smart, modbus, INVT, etc. | ||
86 | |||
87 | D)Taian AP200 C register can not read the value | ||
88 | |||
89 | == **New Functions Added** == | ||
90 | |||
91 | === **PC Software** === | ||
92 | |||
93 | A) VB script customize naming function; | ||
94 | |||
95 | B) PI Suite toolkit; | ||
96 | |||
97 | C) System upgrade function; | ||
98 | |||
99 | D) PIRecordUpload has added User permission function; | ||
100 | |||
101 | E) Cloud function of 8000 and 9000 series; | ||
102 | |||
103 | === **HMI Application** === | ||
104 | |||
105 | The following function is only available for ig series: | ||
106 | |||
107 | A) Slider of History trend chart can set the color and transparency; | ||
108 | |||
109 | B) Continuous read and write addresses in Lua script; | ||
110 | |||
111 | C) Built-in Lua extension module; | ||
112 | |||
113 | D) Display network camera on HMI screen for 8150ig; | ||
114 | |||
115 | E) Vertical Display; | ||
116 | |||
117 | F) The priority settings of Cloud connection method from backstage configuration; | ||
118 | |||
119 | G) Lua script supports https protocol now; | ||
120 | |||
121 | H) UDisk Download project prohibit upload function; | ||
122 | |||
123 | I) Lua script luasqlite operation; | ||
124 | |||
125 | The following function is only available for i,ie,ig series and HMI+ system: | ||
126 | |||
127 | J)All series remove the restriction of special machine code; | ||
128 | |||
129 | K) Recipe 64-bit floating point number data format; | ||
130 | |||
131 | L) UDisk Pop-Up function; | ||
132 | |||
133 | M) Interconversion between GB2312 and UTF-8 encoding; | ||
134 | |||
135 | N) UDisk download PLC multi-file function; | ||
136 | |||
137 | O) Modifitable datetime prohibited; | ||
138 | |||
139 | P) Color configuration of Line object; | ||
140 | |||
141 | === **Driver Protocol** === | ||
142 | |||
143 | A Inovance H3U Ethernet; | ||
144 | |||
145 | B Rockwell micro850 Ethernet/IP Free Tags; | ||
146 | |||
147 | C Wecon LX6V Free Tags; | ||
148 | |||
149 | == **New Models** == | ||
150 | |||
151 | (1)The i series: 3070i-A, 3102i-A, 3070i-C, 3102i-C, 3070i-2S, 3102i-2S | ||
152 | |||
153 | (2)The ie series: 3043ie-T | ||
154 | |||
155 | (3)The ig series: 8150ig | ||
156 | |||
157 | ✎Note: | ||
158 | |||
159 | 1)To use the new functions avaiable from new version, the project needs to be downloaded twice; | ||
160 | |||
161 | 2)After the wifi module (version V1.1) of 3070ig is soft restarted, if the wifi is not recognized from background interface, please repower to recover it; | ||
162 | |||
163 | = **PIStudio Release Build VER:R05R998_V7.2.198_D20211210** = | ||
164 | |||
165 | (% class="wikigeneratedid" %) | ||
166 | **Official Website:** | ||
167 | |||
168 | (% class="wikigeneratedid" %) | ||
169 | **[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20211210.zip]]** | ||
170 | |||
171 | **Google Drive:** | ||
172 | |||
173 | **[[Download Link>>https://drive.google.com/file/d/1lRfgoOwAs7lgL4b-ZdVUvE6itHWCpfd5/view?usp=sharing]]** | ||
174 | |||
175 | == **Bugs Fixed** == | ||
176 | |||
177 | === **PC Software** === | ||
178 | |||
179 | A) Optimize the display style of text objects; | ||
180 | |||
181 | B) Optimize Lua script file size limitation to 512KB; | ||
182 | |||
183 | C) Optimize the import of text library and the limitation to 2000; | ||
184 | |||
185 | D) Protocol driver names standardized; | ||
186 | |||
187 | E) Font size is open to 512; | ||
188 | |||
189 | F) Lua script debugging window can be configured as enabled or not in Project Settings; | ||
190 | |||
191 | G) Optimize the font display of Runbar; | ||
192 | |||
193 | H) Optimized the forced backup function of project file, now you can click the cancel button to not backup; | ||
194 | |||
195 | I) Optimized and adjusted the default size of the password keyboard screen of newly-created projects; | ||
196 | |||
197 | J) Wrong display range of the History trend chart; | ||
198 | |||
199 | K) The font display of Drop-down List on PC is different from the actual screen; | ||
200 | |||
201 | L) Software crash caused by deleting the Address Library name; | ||
202 | |||
203 | M) General Series SMS protocol cannot be selected; | ||
204 | |||
205 | === **HMI Application** === | ||
206 | |||
207 | A) Multi-Language display of text fonts; | ||
208 | |||
209 | B) Password keyboard input to display the plain text first and then the * sign; | ||
210 | |||
211 | C) Prompt display of Screen Lock for ie and ig; | ||
212 | |||
213 | D) Auto refresh of Data Record; | ||
214 | |||
215 | === **Driver Protocol** === | ||
216 | |||
217 | A) Communication cannot be performed after entering the backstage project; | ||
218 | |||
219 | B) Stuck screen problem caused by the protocol IEC60870-104 Client; | ||
220 | |||
221 | == **New Functions Added** == | ||
222 | |||
223 | === **PC Software** === | ||
224 | |||
225 | A) New ie series model: 3035ie; | ||
226 | |||
227 | B) New ig series models: 3070ig, 3102ig; | ||
228 | |||
229 | C) License agreement for the software installation setup process; | ||
230 | |||
231 | D) Object Lock/Unlock function (Pushpin); | ||
232 | |||
233 | E) Lua Editor to highlight the same content of the selected text; | ||
234 | |||
235 | F) Font style settings of the Runbar and chart type objects; | ||
236 | |||
237 | G) Software installation package VC 2017 runtime library; | ||
238 | |||
239 | === **HMI Application** === | ||
240 | |||
241 | A) Recipe address discontinuous address setting; | ||
242 | |||
243 | B) Trim 0 display setting for numeric input; | ||
244 | |||
245 | C) Address Mapping continuous writing settings; | ||
246 | |||
247 | D) Screensaver function; | ||
248 | |||
249 | E) Multi-Link function (not supported by ie and ig series); | ||
250 | |||
251 | F) Traditional recipe function is only applicable to the LEVI2PI project that uses the Recipe function; | ||
252 | |||
253 | G) Disc Record Chart; | ||
254 | |||
255 | H) Lua script weather forecast function interfaces; | ||
256 | |||
257 | I) The ie series supports the barcode scanner; | ||
258 | |||
259 | === **Driver Protocol** === | ||
260 | |||
261 | A) Koyo Modbus RTU; | ||
262 | |||
263 | B) ASK series; | ||
264 | |||
265 | C) Anda inverter; | ||
266 | |||
267 | D) Optimize the barcode scanner protocol; | ||
268 | |||
269 | = **PIStudio Release Build VER:R05R998_V7.1.117_D20210320** = | ||
270 | |||
271 | **Official Website:** | ||
272 | |||
273 | **[[Download Link>>https://ftp.we-con.com.cn/Download/Software/PIStudio20210320.zip]]** | ||
274 | |||
275 | **Dropbox:** | ||
276 | |||
277 | **[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=PIStudio20210320.zip&subfolder_nav_tracking=1]]** | ||
278 | |||
279 | == **Bugs Fixed** == | ||
280 | |||
281 | === **PC Software** === | ||
282 | |||
283 | A) Fix the crash problem of the software; | ||
284 | |||
285 | B) Renew the wiring diagram and pin definition diagram; | ||
286 | |||
287 | C) After the address is annotated, still able to communicate in Lua script; | ||
288 | |||
289 | D) Ethernet download optimization; | ||
290 | |||
291 | E) The project folder contains special language characters(except Chinese and English), errors in compiling Lua file and project, failed to download the project; | ||
292 | |||
293 | F) Use some fonts will cause software crash when compiling the project; | ||
294 | |||
295 | === **HMI Application** === | ||
296 | |||
297 | A) Occasionally occur stuck logo problem after enable the Index of Recipe function; | ||
298 | |||
299 | B) Frequently screen switching might have a little chance cause stuck problem if there exist many table objects on the screen; | ||
300 | |||
301 | C) There is a little chance cause the stuck problem if use the script; | ||
302 | |||
303 | D) The stuck problem if use User permission; | ||
304 | |||
305 | E) The stuck problem when Data record upload; | ||
306 | |||
307 | F) There is a little chance to jump to the test interface after restart; | ||
308 | |||
309 | G) After the backlight is off, there is a small chance that the screen will display abnormal; | ||
310 | |||
311 | H) Video play cause stuck problem of General series 9150; | ||
312 | |||
313 | I) When the HMI just turned on, Recipe Display on the main screen is displayed as NULL; | ||
314 | |||
315 | J) Optimize Lua built-in library and file read/write functions; | ||
316 | |||
317 | K) The label of the operation value in the Operation record is displayed abnormal; | ||
318 | |||
319 | L) The length of channel name for Data record exceeds 32 bytes, will cause failed recording; | ||
320 | |||
321 | M) After entering the installment password, restart immediately, would require entering the password again; | ||
322 | |||
323 | === **Driver Protocol** === | ||
324 | |||
325 | A) Frequently screen switching and there are many external addresses on the screen, which might have a little chance cause a stuck problem; | ||
326 | |||
327 | B) Ethernet free tags may cause touch problem with no response; | ||
328 | |||
329 | C) Ethernet free tags occur error in compiling the project; | ||
330 | |||
331 | D) The input/output terminals of communication with MIKOM PLC are abnormal; | ||
332 | |||
333 | E) The reading information from scanner will not display if it exceeds 128 characters; | ||
334 | |||
335 | F) Failed to communicate with the OMRON NX/NJ PLC communication after power-on the screen and then power on the PLC. | ||
336 | |||
337 | G) When HMI+ is just turned on, the Ethernet communication prompts timeout; | ||
338 | |||
339 | H) When communicate with Siemens new protocol, will let the HMI stuck on LOGO screen; | ||
340 | |||
341 | == **New Functions Added** == | ||
342 | |||
343 | === **PC Software** === | ||
344 | |||
345 | A) New ie series: 3043ie, 3043ieS, 3070ie, 3102ie; | ||
346 | |||
347 | B) Industry purpose-designated models: ie series 3070ind, 3102ind, I series 3070ind-n; | ||
348 | |||
349 | C) Import and export function for Gallery file ( .blb or .plb format); | ||
350 | |||
351 | === **HMI Application** === | ||
352 | |||
353 | A) VNC LAN monitoring function ( require i series and PI+ models with Ethernet port and customized, the -O model in General series still use HMI Monitor System) | ||
354 | |||
355 | B) Resource report function to count the total memory used by the current screen; | ||
356 | |||
357 | C) Message prompt list (timeout , message , only available for ie series); | ||
358 | |||
359 | D) Timer and Trigger function in Lua script (only available for ie series); | ||
360 | |||
361 | E) Lua custom object, Lua table drawing, Lua curve drawing (only available for ie series); | ||
362 | |||
363 | F) Continuous input function of numeric and character object; | ||
364 | |||
365 | G) 4 Macro script functions involving file operations, FileCmpDir(), MyDeleteFile(), WriteWordToFile(), ReadWordFormFile(); | ||
366 | |||
367 | H) The backstage interface can upgrade PLC program to support 5VPLC program download (only available for 3000i and PI+ series); | ||
368 | |||
369 | == **Driver Protocol** == | ||
370 | |||
371 | A) Keyence KV series; | ||
372 | |||
373 | == **Notification of PI+** == | ||
374 | |||
375 | **[[Download Link>>url:https://drive.google.com/file/d/1UMb8YGc5lLSfoF_UHD5A4HwE_HKd-Qg7/view?usp=sharing]]** | ||
376 | |||
377 | = **Levi2PI V4.3.8** = | ||
378 | |||
379 | **Official Website:** | ||
380 | |||
381 | **[[Download Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20LEVI2PI.zip]]** | ||
382 | |||
383 | **Dropbox:** | ||
384 | |||
385 | **[[Download Link>>https://www.dropbox.com/sh/02lklismo8jya3q/AABIZ-3k8wK082DImdmXJG4ra/2.%20Software/HMI?dl=0&preview=Wecon+LEVI2PI.zip&subfolder_nav_tracking=1]]** | ||
386 | |||
387 | = **Levi2PI V4.5.6(Test Version)** = | ||
388 | |||
389 | **Google Drive** | ||
390 | |||
391 | **[[Download Link>>https://drive.google.com/file/d/10Ay8dr7MK6CCpMIKEmKITG3DGipffJsI/view?usp=sharing]]** | ||
392 | |||
393 | = **HMI Monitor System20210317** = | ||
394 | |||
395 | **Google Drive:** | ||
396 | |||
397 | **[[Download Link>>https://drive.google.com/file/d/1RA3ui3jTCKtQTCLySjD4Qi7Ut58EYYD1/view?usp=sharing]]** | ||
398 | |||
399 | |||
400 | = **6 Logo Making Tool** = | ||
401 | |||
402 | **Google Drive:** | ||
403 | |||
404 | **[[Download Link>>https://drive.google.com/file/d/1sGQ8nD9yTJSrM4M7Y3-imdlYnGdpdGHe/view?usp=sharing]]** |