Wiki source code of Barcode Scanner
Last modified by Hunter on 2023/08/24 18:13
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | = {{id name="HBarcodeScanner"/}}**Barcode Scanner** = | ||
2 | |||
3 | Supported: DELI 14880 barcode scanner | ||
4 | |||
5 | **HMI Setting** | ||
6 | |||
7 | |**Items**|**Settings**|**Note** | ||
8 | |Protocol|Barcode Scanner| | ||
9 | |Connection|USB| | ||
10 | |||
11 | **Operating Procedures** | ||
12 | |||
13 | Select [Barcode Scanner]; | ||
14 | |||
15 | {{id name="I12.PLCProtocol_html_55a3056357320966.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f65f7d2f2c4465fe.png||alt="12.PLC Protocol_html_55a3056357320966.png" height="266" width="600"]] | ||
16 | |||
17 | Set address for receiving; | ||
18 | |||
19 | Set correct length; | ||
20 | |||
21 | {{id name="I12.PLCProtocol_html_30a4c9e9dd4db40b.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_6e7cb3ab935dae51.png||alt="12.PLC Protocol_html_30a4c9e9dd4db40b.png" height="701" width="500"]] | ||
22 | |||
23 | **✎Note:** | ||
24 | |||
25 | * The protocol uploads the information acquired by the USB scanner to the HMI; | ||
26 | * The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; | ||
27 | * Recommended model: DELI 14880 barcode scanner; |