Wiki source code of Delta
Version 21.1 by Devin Chen on 2023/09/26 14:05
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | = {{id name="HDelta"/}}**Delta** = | ||
2 | |||
3 | == {{id name="HDVPSeries"/}}**DVP Series** == | ||
4 | |||
5 | Supported Series: Delta DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX Controller | ||
6 | |||
7 | **HMI Settings** | ||
8 | |||
9 | |=**Item**|=**Settings**|=**Note** | ||
10 | |Protocol|DELTA DVP Series| | ||
11 | |Connection|RS485| | ||
12 | |Baud rate|9600| | ||
13 | |Data bit|7| | ||
14 | |Parity|Even| | ||
15 | |Stop bit|1| | ||
16 | |PLC station No.|1~~255|Need to be the same as PLC settings | ||
17 | |||
18 | **Address List** | ||
19 | |||
20 | |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** | ||
21 | |Bit|X|X|X d|0~~303237| | ||
22 | |Bit|Y|Y|Y d|0~~303237| | ||
23 | |Bit|M|M|M d|0~~99999| | ||
24 | |Bit|T|T|T d|0~~99999| | ||
25 | |Bit|C|C|T d|0~~99999| | ||
26 | |Bit|S|S|T d|0~~99999| | ||
27 | |Word|D|D|D d|0~~99999| | ||
28 | |Word|T|T|T d|0~~99999| | ||
29 | |Word|C|C|C d|0~~99999| | ||
30 | |||
31 | **Configure the communication protocol** | ||
32 | |||
33 | {{id name="Iimage-20220829152327-6.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_de5af5621084c16e.png||alt="image-20220829152327-6.png" height="735" width="616"]] | ||
34 | |||
35 | {{id name="Iimage-20220829152016-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_efc2ea365a80a69.png||alt="image-20220829152016-3.png" height="905" width="1038"]] | ||
36 | |||
37 | **Cable Wiring** | ||
38 | |||
39 | {{id name="Iimage-20220829152102-5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95279b21a0902ff5.png||alt="image-20220829152102-5.png" height="241" width="393"]] | ||
40 | |||
41 | == {{id name="HDVPModbusTCP"/}}**DVP Modbus TCP** == | ||
42 | |||
43 | Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller | ||
44 | |||
45 | **HMI Settings** | ||
46 | |||
47 | |=**Items**|=**Settings**|=**Note** | ||
48 | |Protocol|DELTA DVP Modbus TCP| | ||
49 | |Connection|Ethernet| | ||
50 | |Port No.|201|Must be the same as the PLC setting | ||
51 | |PLC station No.|0|Must be the same as the PLC setting | ||
52 | |||
53 | **Address List** | ||
54 | |||
55 | |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** | ||
56 | |Bit|X|X|X o|0~~377| | ||
57 | |Bit|Y|Y|Y o|0~~377| | ||
58 | |Bit|M0|M0|M0 d|0~~1535| | ||
59 | |Bit|M1|M1|M1 d|1536~~4095| | ||
60 | |Bit|T|T|T d|0~~255| | ||
61 | |Bit|C|C|C d|0~~255| | ||
62 | |Bit|S|S|S d|0~~1023| | ||
63 | |Word|D0|D0|D0 d|0~~4095| | ||
64 | |Word|D1|D1|D1 d|4096~~11999| | ||
65 | |Word|T|T|T d|0~~255| | ||
66 | |Word|C|C|C d|0~~199| | ||
67 | |||
68 | **Configure the communication protocol** | ||
69 | |||
70 | {{id name="Iimage-20220829155452-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ade82bcbcffe6d8c.png||alt="image-20220829155452-1.png" height="735" width="616"]] | ||
71 | |||
72 | {{id name="Iimage-20220829162116-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ce5941843aa16b46.png||alt="image-20220829162116-2.png" height="905" width="1038"]] | ||
73 | |||
74 | **Cable Wiring** | ||
75 | |||
76 | {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] | ||
77 | |||
78 | == {{id name="HAS300MODBUSRTU"/}}**AS Series Serial** == | ||
79 | |||
80 | Supported Series: Delta AS200/AS300 | ||
81 | |||
82 | **HMI Settings** | ||
83 | |||
84 | |**Item**|**Settings**|**Note** | ||
85 | |Protocol|DELTA AS300 MODBUS RTU| | ||
86 | |Connection|RS485| | ||
87 | |Baud rate|9600| | ||
88 | |Data bit|8| | ||
89 | |Parity|NONE| | ||
90 | |Stop bit|1| | ||
91 | |PLC station No.|1| | ||
92 | |||
93 | **Address List** | ||
94 | |||
95 | |=**Type**|=(% style="width: 319px;" %)**Device registers**|=(% style="width: 259px;" %)**Format**|=**Range**|=**Note** | ||
96 | |Bit|(% style="width:319px" %)X|(% style="width:259px" %)Xdd.dd|0~~63.15|Read only | ||
97 | |Bit|(% style="width:319px" %)Y|(% style="width:259px" %)Ydd.dd|0~~63.15| | ||
98 | |Bit|(% style="width:319px" %)D|(% style="width:259px" %)Dddddd|0~~29999| | ||
99 | |Bit|(% style="width:319px" %)M|(% style="width:259px" %)Mdddd|0~~8191| | ||
100 | |Bit|(% style="width:319px" %)SM|(% style="width:259px" %)SMdddd|0~~4095| | ||
101 | |Bit|(% style="width:319px" %)S|(% style="width:259px" %)Sdddd|0~~2047| | ||
102 | |Bit|(% style="width:319px" %)T|(% style="width:259px" %)Tddd|0~~511| | ||
103 | |Bit|(% style="width:319px" %)C|(% style="width:259px" %)Cddd|0~~511| | ||
104 | |Bit|(% style="width:319px" %)HC|(% style="width:259px" %)HCddd|0~~255|Double Word | ||
105 | |Word|(% style="width:319px" %)X|(% style="width:259px" %)Xdd|0~~63| | ||
106 | |Word|(% style="width:319px" %)Y|(% style="width:259px" %)Ydd|0~~63| | ||
107 | |Word|(% style="width:319px" %)SR|(% style="width:259px" %)SRdddd|0~~2047|Special register | ||
108 | |Word|(% style="width:319px" %)D|(% style="width:259px" %)Dddddd|0~~29999| | ||
109 | |Word|(% style="width:319px" %)T|(% style="width:259px" %)Tddd|0~~511| | ||
110 | |Word|(% style="width:319px" %)C|(% style="width:259px" %)Cddd|0~~511| | ||
111 | |Word|(% style="width:319px" %)E|(% style="width:259px" %)Ed|0~~9| | ||
112 | |||
113 | **Configure the communication protocol** | ||
114 | |||
115 | Create project | ||
116 | |||
117 | {{id name="IAsCreateProject.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_b7f7269dc8e83a21.png||alt="AsCreateProject.png" height="729" width="1366"]] | ||
118 | |||
119 | Open the tool COMMGR, to communicate with PLC, if know the IP, we can directly click Add to input PLC IP. Or search the PLC IP from LAN. | ||
120 | |||
121 | {{id name="IAScommunicarw.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e7d08035f5930e76.png||alt="AScommunicarw.png" height="533" width="616"]] | ||
122 | |||
123 | Double click the HWCONFIG to open the communication settings window. | ||
124 | |||
125 | {{id name="IASHWCONFIG.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e75cc09b89b3b7b1.png||alt="ASHWCONFIG.png" height="728" width="1366"]] | ||
126 | |||
127 | Expand the Project Tree, open the hardware configuration, double click the PLC icon. | ||
128 | |||
129 | {{id name="IASHSCONFIGICON.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_daa6b9d7d45cdb0a.png||alt="ASHSCONFIGICON.png" height="702" width="932"]] | ||
130 | |||
131 | Click COM1 Port Setting, the default Modbus mode is ASCII, need to change to RTU. | ||
132 | |||
133 | {{id name="IASModbusMode.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_3df2c64600444264.png||alt="ASModbusMode.png" height="702" width="932"]] | ||
134 | |||
135 | Click Ethernet Port Basic Setting, set the PLC IP and Gateway. Make sure the IP and Gateway is same segment. Then download into PLC. | ||
136 | |||
137 | {{id name="IASconfigIP.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_da011ceb3ea3e4dc.png||alt="ASconfigIP.png" height="702" width="932"]] | ||
138 | |||
139 | {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="image-20220830094600-1.png" height="38" width="76"]] | ||
140 | |||
141 | {{id name="Iimage-20220830094657-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d2502d89d0bffd41.png||alt="image-20220830094657-2.png" height="905" width="1038"]] | ||
142 | |||
143 | **Cable Wiring** | ||
144 | |||
145 | {{id name="Iimage-20220830141138-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f8fe0b0ed8eeae70.png||alt="image-20220830141138-1.png" height="202" width="629"]] | ||
146 | |||
147 | Pin Definition Diagram | ||
148 | |||
149 | {{id name="Iimage-20220830095131-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a71ae15340c23f6d.png||alt="image-20220830095131-1.png" height="230" width="342"]] | ||
150 | |||
151 | == {{id name="HAS300MODBUSTCP"/}}**AS Series Ethernet** == | ||
152 | |||
153 | **HMI Settings** | ||
154 | |||
155 | |=**Items**|=**Settings**|=**Note** | ||
156 | |Protocol|DELTA AS300 MODBUS TCP| | ||
157 | |Connection|Ethernet| | ||
158 | |Port No.|502| | ||
159 | |Device No.|1| | ||
160 | |HMI No.|0| | ||
161 | |||
162 | **Address List** | ||
163 | |||
164 | |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** | ||
165 | |Bit|X|X|X d|0~~63| | ||
166 | |Bit|Y|Y|Y d|0~~63| | ||
167 | |Bit|D|D|D d|0~~29999| | ||
168 | |Bit|M|M|M d|0~~8191| | ||
169 | |Bit|SM|SM|SM d|0~~4095| | ||
170 | |Bit|S|S|S h|0~~2047| | ||
171 | |Bit|T|T|T d|0~~511| | ||
172 | |Bit|C|C|C d|0~~511| | ||
173 | |Bit|HC|HC|HC d|0~~255| | ||
174 | |Word|X|X|X h|0~~63| | ||
175 | |Word|Y|Y|Y d|0~~63| | ||
176 | |Word|SR|SR|SR d|0~~2047| | ||
177 | |Word|D|D|D d|0~~29999| | ||
178 | |Word|T|T|T d|0~~511| | ||
179 | |Word|C|C|C h|0~~511| | ||
180 | |Word|E|E|E d|0~~9| | ||
181 | |||
182 | **Configure the communication protocol** | ||
183 | |||
184 | {{id name="Iimage-20220830140537-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_18ef1d1ef3759c1c.png||alt="image-20220830140537-1.png" height="735" width="616"]] | ||
185 | |||
186 | {{id name="Iimage-20220830140629-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e2240cfba5d009c9.png||alt="image-20220830140629-2.png" height="905" width="1038"]] | ||
187 | |||
188 | **PLC Setting** | ||
189 | |||
190 | 1.Open COMMGR ,[Add]→[Driver Name] Driver1→[Connection Setup]→[Type] Ethernet→[Ethernet Card] →[Description] Realtek PCIe GBE Family Controller→[Search] PC and PLC are in | ||
191 | the same LAN, click the corresponding PLC IP searched.→[OK] | ||
192 | |||
193 | (% style="text-align:center" %) | ||
194 | [[image:1.3.1.png]] | ||
195 | |||
196 | 2. Open ISPSoft,[Project]→Double click[HWCONFIG] | ||
197 | |||
198 | (% style="text-align:center" %) | ||
199 | [[image:1.3.2.png]] | ||
200 | |||
201 | PLC Default Parameters: | ||
202 | [Device]→[Hardware Configuration]→[CPU(AS332T-A)]→[Hardware Configuration]→[General] →[Ethernet Port Basic Setting]: [IP Address]192.168.40.122, [Subnet Mask]255.255.255.0,[Gateway] | ||
203 | 192.168.40.1→[Download] | ||
204 | |||
205 | (% style="text-align:center" %) | ||
206 | [[image:1.3.3-.png]] | ||
207 | |||
208 | (% style="text-align:center" %) | ||
209 | [[image:1.3.4.png]] | ||
210 | |||
211 | **Cable Wiring** | ||
212 | |||
213 | {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-2"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] |