Wiki source code of Delta

Last modified by Theodore Xu on 2023/10/10 11:03

Show last authors
1 = {{id name="HDelta"/}}**Delta** =
2
3 == {{id name="HDVPSeries"/}}**DVP Series** ==
4
5 Supported Series: Delta DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX Controller
6
7 **HMI Settings**
8
9 |=**Item**|=**Settings**|=**Note**
10 |Protocol|DELTA DVP Series|
11 |Connection|RS485|
12 |Baud rate|9600|
13 |Data bit|7|
14 |Parity|Even|
15 |Stop bit|1|
16 |PLC station No.|1~~255|Need to be the same as PLC settings
17
18 **Address List**
19
20 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
21 |Bit|X|X|X d|0~~303237|
22 |Bit|Y|Y|Y d|0~~303237|
23 |Bit|M|M|M d|0~~99999|
24 |Bit|T|T|T d|0~~99999|
25 |Bit|C|C|T d|0~~99999|
26 |Bit|S|S|T d|0~~99999|
27 |Word|D|D|D d|0~~99999|
28 |Word|T|T|T d|0~~99999|
29 |Word|C|C|C d|0~~99999|
30
31 **Configure the communication protocol**
32
33 {{id name="Iimage-20220829152327-6.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_de5af5621084c16e.png||alt="image-20220829152327-6.png" height="735" width="616"]]
34
35 {{id name="Iimage-20220829152016-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_efc2ea365a80a69.png||alt="image-20220829152016-3.png" height="905" width="1038"]]
36
37 **Cable Wiring**
38
39 {{id name="Iimage-20220829152102-5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95279b21a0902ff5.png||alt="image-20220829152102-5.png" height="241" width="393"]]
40
41 == {{id name="HDVPModbusTCP"/}}**DVP Modbus TCP** ==
42
43 Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller
44
45 **HMI Settings**
46
47 |=**Items**|=**Settings**|=**Note**
48 |Protocol|DELTA DVP Modbus TCP|
49 |Connection|Ethernet|
50 |Port No.|201|Must be the same as the PLC setting
51 |PLC station No.|0|Must be the same as the PLC setting
52
53 **Address List**
54
55 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
56 |Bit|X|X|X o|0~~377|
57 |Bit|Y|Y|Y o|0~~377|
58 |Bit|M0|M0|M0 d|0~~1535|
59 |Bit|M1|M1|M1 d|1536~~4095|
60 |Bit|T|T|T d|0~~255|
61 |Bit|C|C|C d|0~~255|
62 |Bit|S|S|S d|0~~1023|
63 |Word|D0|D0|D0 d|0~~4095|
64 |Word|D1|D1|D1 d|4096~~11999|
65 |Word|T|T|T d|0~~255|
66 |Word|C|C|C d|0~~199|
67
68 **Configure the communication protocol**
69
70 {{id name="Iimage-20220829155452-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ade82bcbcffe6d8c.png||alt="image-20220829155452-1.png" height="735" width="616"]]
71
72 {{id name="Iimage-20220829162116-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ce5941843aa16b46.png||alt="image-20220829162116-2.png" height="905" width="1038"]]
73
74 **Cable Wiring**
75
76 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
77
78 == **AS Series Serial** ==
79
80 Supported Series: Delta AS200/AS300
81
82 **HMI Settings**
83
84 |**Item**|**Settings**|**Note**
85 |Protocol|DELTA AS300 MODBUS RTU|
86 |Connection|RS485|
87 |Baud rate|9600|
88 |Data bit|8|
89 |Parity|NONE|
90 |Stop bit|1|
91 |PLC station No.|1|
92
93 **Address List**
94
95 |=**Type**|=(% style="width: 253px;" %)**Device registers**|=(% style="width: 251px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
96 |(% colspan="1" rowspan="9" %)Bit|(% style="width:253px" %)X|(% style="width:251px" %)Xdd.dd|(% style="width:225px" %)0~~63.15|Read only
97 |(% style="width:253px" %)Y|(% style="width:251px" %)Ydd.dd|(% style="width:225px" %)0~~63.15|
98 |(% style="width:253px" %)D|(% style="width:251px" %)Dddddd|(% style="width:225px" %)0~~29999|
99 |(% style="width:253px" %)M|(% style="width:251px" %)Mdddd|(% style="width:225px" %)0~~8191|
100 |(% style="width:253px" %)SM|(% style="width:251px" %)SMdddd|(% style="width:225px" %)0~~4095|
101 |(% style="width:253px" %)S|(% style="width:251px" %)Sdddd|(% style="width:225px" %)0~~2047|
102 |(% style="width:253px" %)T|(% style="width:251px" %)Tddd|(% style="width:225px" %)0~~511|
103 |(% style="width:253px" %)C|(% style="width:251px" %)Cddd|(% style="width:225px" %)0~~511|
104 |(% style="width:253px" %)HC|(% style="width:251px" %)HCddd|(% style="width:225px" %)0~~255|Double Word
105 |(% colspan="1" rowspan="7" %)Word|(% style="width:253px" %)X|(% style="width:251px" %)Xdd|(% style="width:225px" %)0~~63|
106 |(% style="width:253px" %)Y|(% style="width:251px" %)Ydd|(% style="width:225px" %)0~~63|
107 |(% style="width:253px" %)SR|(% style="width:251px" %)SRdddd|(% style="width:225px" %)0~~2047|Special register
108 |(% style="width:253px" %)D|(% style="width:251px" %)Dddddd|(% style="width:225px" %)0~~29999|
109 |(% style="width:253px" %)T|(% style="width:251px" %)Tddd|(% style="width:225px" %)0~~511|
110 |(% style="width:253px" %)C|(% style="width:251px" %)Cddd|(% style="width:225px" %)0~~511|
111 |(% style="width:253px" %)E|(% style="width:251px" %)Ed|(% style="width:225px" %)0~~9|
112
113 **Configure the communication protocol**
114
115 Create project
116
117 {{id name="IAsCreateProject.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_b7f7269dc8e83a21.png||alt="AsCreateProject.png" height="729" width="1366"]]
118
119 Open the tool COMMGR, to communicate with PLC, if know the IP, we can directly click Add to input PLC IP. Or search the PLC IP from LAN.
120
121 {{id name="IAScommunicarw.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e7d08035f5930e76.png||alt="AScommunicarw.png" height="533" width="616"]]
122
123 Double click the HWCONFIG to open the communication settings window.
124
125 {{id name="IASHWCONFIG.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e75cc09b89b3b7b1.png||alt="ASHWCONFIG.png" height="728" width="1366"]]
126
127 Expand the Project Tree, open the hardware configuration, double click the PLC icon.
128
129 {{id name="IASHSCONFIGICON.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_daa6b9d7d45cdb0a.png||alt="ASHSCONFIGICON.png" height="702" width="932"]]
130
131 Click COM1 Port Setting, the default Modbus mode is ASCII, need to change to RTU.
132
133 {{id name="IASModbusMode.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_3df2c64600444264.png||alt="ASModbusMode.png" height="702" width="932"]]
134
135 Click Ethernet Port Basic Setting, set the PLC IP and Gateway. Make sure the IP and Gateway is same segment. Then download into PLC.
136
137 {{id name="IASconfigIP.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_da011ceb3ea3e4dc.png||alt="ASconfigIP.png" height="702" width="932"]]
138
139
140 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d2502d89d0bffd41.png||alt="image-20220830094657-2.png" height="905" width="1038"]]
141
142 **Cable Wiring**
143
144 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f8fe0b0ed8eeae70.png||alt="image-20220830141138-1.png" height="202" width="629"]]
145
146 Pin Definition Diagram
147
148 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a71ae15340c23f6d.png||alt="image-20220830095131-1.png" height="230" width="342"]]
149
150 == **AS Series Ethernet** ==
151
152 **HMI Settings**
153
154 |=**Items**|=**Settings**|=**Note**
155 |Protocol|DELTA AS300 MODBUS TCP|
156 |Connection|Ethernet|
157 |Port No.|502|
158 |Device No.|1|
159 |HMI No.|0|
160
161 **Address List**
162
163 |=**Type**|=(% style="width: 258px;" %)**Device registers**|=(% style="width: 262px;" %)**Format**|=(% style="width: 231px;" %)**Range**|=(% style="width: 174px;" %)**Note**
164 |(% colspan="1" rowspan="9" %)Bit|(% style="width:258px" %)X|(% style="width:262px" %)X d|(% style="width:231px" %)0~~63|(% style="width:174px" %)
165 |(% style="width:258px" %)Y|(% style="width:262px" %)Y d|(% style="width:231px" %)0~~63|(% style="width:174px" %)
166 |(% style="width:258px" %)D|(% style="width:262px" %)D d|(% style="width:231px" %)0~~29999|(% style="width:174px" %)
167 |(% style="width:258px" %)M|(% style="width:262px" %)M d|(% style="width:231px" %)0~~8191|(% style="width:174px" %)
168 |(% style="width:258px" %)SM|(% style="width:262px" %)SM d|(% style="width:231px" %)0~~4095|(% style="width:174px" %)
169 |(% style="width:258px" %)S|(% style="width:262px" %)S h|(% style="width:231px" %)0~~2047|(% style="width:174px" %)
170 |(% style="width:258px" %)T|(% style="width:262px" %)T d|(% style="width:231px" %)0~~511|(% style="width:174px" %)
171 |(% style="width:258px" %)C|(% style="width:262px" %)C d|(% style="width:231px" %)0~~511|(% style="width:174px" %)
172 |(% style="width:258px" %)HC|(% style="width:262px" %)HC d|(% style="width:231px" %)0~~255|(% style="width:174px" %)
173 |(% colspan="1" rowspan="7" %)Word|(% style="width:258px" %)X|(% style="width:262px" %)X h|(% style="width:231px" %)0~~63|(% style="width:174px" %)
174 |(% style="width:258px" %)Y|(% style="width:262px" %)Y d|(% style="width:231px" %)0~~63|(% style="width:174px" %)
175 |(% style="width:258px" %)SR|(% style="width:262px" %)SR d|(% style="width:231px" %)0~~2047|(% style="width:174px" %)
176 |(% style="width:258px" %)D|(% style="width:262px" %)D d|(% style="width:231px" %)0~~29999|(% style="width:174px" %)
177 |(% style="width:258px" %)T|(% style="width:262px" %)T d|(% style="width:231px" %)0~~511|(% style="width:174px" %)
178 |(% style="width:258px" %)C|(% style="width:262px" %)C h|(% style="width:231px" %)0~~511|(% style="width:174px" %)
179 |(% style="width:258px" %)E|(% style="width:262px" %)E d|(% style="width:231px" %)0~~9|(% style="width:174px" %)
180
181 **Configure the communication protocol**
182
183 {{id name="Iimage-20220830140537-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_18ef1d1ef3759c1c.png||alt="image-20220830140537-1.png" height="735" width="616"]]
184
185 {{id name="Iimage-20220830140629-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e2240cfba5d009c9.png||alt="image-20220830140629-2.png" height="905" width="1038"]]
186
187 **PLC Setting**
188
189 1.Open COMMGR ,[Add]→[Driver Name] Driver1→[Connection Setup]→[Type] Ethernet→[Ethernet Card] →[Description] Realtek PCIe GBE Family Controller→[Search] PC and PLC are in
190 the same LAN, click the corresponding PLC IP searched.→[OK]
191
192 (% style="text-align:center" %)
193 [[image:1.3.1.png]]
194
195 2. Open ISPSoft,[Project]→Double click[HWCONFIG]
196
197 (% style="text-align:center" %)
198 [[image:1.3.2.png]]
199
200 PLC Default Parameters:
201 [Device]→[Hardware Configuration]→[CPU(AS332T-A)]→[Hardware Configuration]→[General] →[Ethernet Port Basic Setting]: [IP Address]192.168.40.122, [Subnet Mask]255.255.255.0,[Gateway]
202 192.168.40.1→[Download]
203
204 (% style="text-align:center" %)
205 [[image:1.3.3-.png]]
206
207 (% style="text-align:center" %)
208 [[image:1.3.4-.png||alt="1.3.4.png"]]
209
210 **Cable Wiring**