1 += {{id name="HHitachiEHVSeries28Ethernet29"/}}**Hitachi EHV Series(Ethernet)** =
2 +
3 +Supported series: Hitachi EHV series
4 +
5 +**HMI Settings**
6 +
7 +|**Items**|**Settings**|**Note**
8 +|Protocol|Hitachi EHV series|
9 +|Connection|Ethernet|
10 +|Port No.|3004~~3007|
11 +
12 +**Address List**
13 +
14 +|**Type**|**Register**|**Range**|**Format**|**Note**
15 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
16 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
17 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
18 +H1H2H3H4 Module main number
19 +
20 +H1: Remote number
21 +
22 +H2: Unit number
23 +
24 +H3: Slot number
25 +
26 +H4: Word number of Module
27 +
28 +H Sub number of Module
29 +
30 +For example:X21.3
31 +
32 +Slot number 2
33 +
34 +Word number of module is 1
35 +
36 +Bit number of module is 3
37 +
38 +Remote number and unit number are 0
39 +)))
40 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
41 +|R|0 – FF.f (Hex)|R HH.h|
42 +|L|0 - 73FF.f (Hex)|L HHHH.h|
43 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
44 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
45 +H1H2H3H4 Module main number
46 +
47 +H1: Remote number
48 +
49 +H2: Unit number
50 +
51 +H3: Slot number
52 +
53 +H4: Word number of module
54 +
55 +For example:WX21
56 +
57 +Word number of module is 1
58 +
59 +Slot number is 2
60 +
61 +Remote number and unit number are 0
62 +)))
63 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
64 +|WR|0 – FFFF (Hex)|WR HHHH|
65 +|WL|0 - 73FF (Hex)|WL HHHH|
66 +|TC|0 - 2559|TC DDDD|
67 +
68 +**Communication settings in HMI**
69 +
70 +Enable HMI Ethernet in [Project Settings];
71 +
72 +{{id name="I12.PLCProtocol_html_43b671f18153910d.png-10"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
73 +
74 +Set PLC IP in [Device IP] settings;
75 +
76 +{{id name="I12.PLCProtocol_html_d825387f5bde6cdd.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_289c88a577ae4a46.png||alt="12.PLC Protocol_html_d825387f5bde6cdd.png" height="190" width="554"]]
77 +
78 +**PLC Configuration**
79 +
80 +Connect with PLC, select[Online mode];
81 +
82 +{{id name="I12.PLCProtocol_html_8430dda44e5c199c.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ad740610d89d5a5.png||alt="12.PLC Protocol_html_8430dda44e5c199c.png" height="420" width="600"]]
83 +
84 +Set IP address, it is the same LAN parameters with HMI;
85 +
86 +{{id name="I12.PLCProtocol_html_1d8a634f64e25fc3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_6c44ec0dd68a8178.png||alt="12.PLC Protocol_html_1d8a634f64e25fc3.png" height="252" width="347"]]
87 +
88 +3) Save PLC communication parameter, and restart PLC
89 +
90 +**PLC Monitor Mode**
91 +
92 +Connect with PLC and choose to “online” mode
93 +
94 +{{id name="I12.PLCProtocol_html_cdac598e770e3b67.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_b7901a5bd0eeb61b.png||alt="12.PLC Protocol_html_cdac598e770e3b67.png" height="193" width="553"]]
95 +
96 +Open I/O monitor sheet1
97 +
98 +{{id name="I12.PLCProtocol_html_68eb3518e5f80892.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_83f9d95ebe51b732.png||alt="12.PLC Protocol_html_68eb3518e5f80892.png" height="369" width="559"]]
99 +
100 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
101 +
102 +{{id name="I12.PLCProtocol_html_774652d8daf548d4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d59ca3d6485fea4c.png||alt="12.PLC Protocol_html_774652d8daf548d4.png" height="118" width="102"]]
103 +
104 +Enter the register address, click OK to view the value of the register.
105 +
106 +{{id name="I12.PLCProtocol_html_bba169c300c92051.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1b29325e43b74ad6.png||alt="12.PLC Protocol_html_bba169c300c92051.png" height="404" width="600"]]
107 +
108 +{{id name="I12.PLCProtocol_html_d3b23bb9e81921a3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ba6111029fd4b197.png||alt="12.PLC Protocol_html_d3b23bb9e81921a3.png" height="404" width="600"]]
109 +
110 +**✎Note:**
111 +
112 +* Both word registers and bit registers support even continuous read/write functions;
113 +* The range of registers is based on the specific PLC type;
114 +
115 +**Cable Wiring**
116 +