Changes for page IEC60870-5 104 Client
Last modified by Cong Hoang Huu on 2024/06/20 11:28
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
- xwiki_PIStudio_12.PLC+protocols_WebHome_74e58fa452e39f04.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_bb129c90855e23a3.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_c3240b50b359cc.png
-
Objects (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,0 +1,1 @@ 1 +IEC60870-5 104 Client - Parent
-
... ... @@ -1,0 +1,1 @@ 1 +PIStudio.PLC Protocol.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.congrice - Content
-
... ... @@ -1,0 +1,60 @@ 1 += {{id name="HIEC60870-5104Client"/}}**IEC60870-5 104 Client** = 2 + 3 +**HMI Setting** 4 + 5 +|**Items**|**Settings**|**Note** 6 +|Protocol|IEC60870-5 104 Client| 7 +|Connection|Ethernet| 8 +|Port No.|2404| 9 + 10 +**Address List** 11 + 12 +|**Type**|**Register**|**Range** 13 +|(% rowspan="9" %)Bit|SPTB|0~~16777215.7 14 +|SCNA|0~~16777215.7 15 +|DPTB|0~~16777215.7 16 +|DCNA|0~~16777215.7 17 +|METF|0~~16777215.7 18 +|SENC|0~~16777215.7 19 +|SENA|0~~16777215.7 20 +|MENA|0~~16777215.7 21 +|METD|0~~16777215.7 22 +|(% rowspan="11" %)Word|SPTB|0~~16777215 23 +|SCNA|0~~16777215 24 +|DPTB|0~~16777215 25 +|DCNA|0~~16777215 26 +|SENA|0~~16777215 27 +|MENA|0~~16777215 28 +|METD|0~~16777215 29 +|INRO|0~~16777215 30 +|TIMESYN|0~~16777215 31 +|TIMEZ|0~~16777215 32 +|NTP|0~~16777215 33 +|(% rowspan="2" %)Double word|METF|0~~16777215 34 +|SENC|0~~16777215 35 + 36 +**Address Configuration** 37 + 38 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 39 + 40 +{{id name="I12.PLCProtocol_html_ba78d143bf457ead.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_bb129c90855e23a3.png||alt="12.PLC Protocol_html_ba78d143bf457ead.png" height="369" width="600"]] 41 + 42 +{{id name="I12.PLCProtocol_html_23533fd5bb81f4ab.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c3240b50b359cc.png||alt="12.PLC Protocol_html_23533fd5bb81f4ab.png" height="389" width="600"]] 43 + 44 +Extended tag name 45 + 46 +Address range for the extended tag. 47 + 48 +**Communication Settings** 49 + 50 +Enable HMI Ethernet in [Project Settings]; 51 + 52 +{{id name="I12.PLCProtocol_html_43b671f18153910d.png-11"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]] 53 + 54 +Set PLC IP in [Device IP] settings; 55 + 56 +{{id name="I12.PLCProtocol_html_f848736ec68b125.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_74e58fa452e39f04.png||alt="12.PLC Protocol_html_f848736ec68b125.png" height="191" width="554"]] 57 + 58 +**Cable Wiring** 59 + 60 +{{id name="I12.PLCProtocol_html_2297240b57346b2a.png-8"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- xwiki_PIStudio_12.PLC+protocols_WebHome_74e58fa452e39f04.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.8 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_bb129c90855e23a3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.0 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_c3240b50b359cc.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.7 KB - Content
- XWiki.XWikiComments[0]
-
- Date
-
... ... @@ -1,0 +1,1 @@ 1 +2024-06-20 11:11:02.158 - Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.congrice - Comment
-
... ... @@ -1,0 +1,1 @@ 1 +Tôi đã thay đổi ASDU = 1. Nhưng khi gói tin được truyền đi thì tôi đã dùng phần mềm để bắt và phân tích gói tin, trong frame của gói tin thì ASDU vẫn bằng 0. Dường như ASDU trong frame của gói tin vẫn bằng 0 và không thay đổi dù cho Người dùng có thay đổi ASDU trong Address Library bằng bất cứ giá trị nào. Có ai biết cách xử lý không? Giúp tôi với.
- XWiki.XWikiComments[1]
-
- Date
-
... ... @@ -1,0 +1,1 @@ 1 +2024-06-20 11:28:05.863 - Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.congrice - Comment
-
... ... @@ -1,0 +1,1 @@ 1 +Rất có thể đây là một lỗi lập trình của Driver IEC60870-5 104 Client