1 -= {{id name="HIEC60870-5104Client"/}}**IEC60870-5 104 Client** =
2 -
3 -**HMI Setting**
4 -
5 -|**Items**|**Settings**|**Note**
6 -|Protocol|IEC60870-5 104 Client|
7 -|Connection|Ethernet|
8 -|Port No.|2404|
9 -
10 -**Address List**
11 -
12 -|**Type**|**Register**|**Range**
13 -|(% rowspan="9" %)Bit|SPTB|0~~16777215.7
14 -|SCNA|0~~16777215.7
15 -|DPTB|0~~16777215.7
16 -|DCNA|0~~16777215.7
17 -|METF|0~~16777215.7
18 -|SENC|0~~16777215.7
19 -|SENA|0~~16777215.7
20 -|MENA|0~~16777215.7
21 -|METD|0~~16777215.7
22 -|(% rowspan="11" %)Word|SPTB|0~~16777215
23 -|SCNA|0~~16777215
24 -|DPTB|0~~16777215
25 -|DCNA|0~~16777215
26 -|SENA|0~~16777215
27 -|MENA|0~~16777215
28 -|METD|0~~16777215
29 -|INRO|0~~16777215
30 -|TIMESYN|0~~16777215
31 -|TIMEZ|0~~16777215
32 -|NTP|0~~16777215
33 -|(% rowspan="2" %)Double word|METF|0~~16777215
34 -|SENC|0~~16777215
35 -
36 -**Address Configuration**
37 -
38 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
39 -
40 -{{id name="I12.PLCProtocol_html_ba78d143bf457ead.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_bb129c90855e23a3.png||alt="12.PLC Protocol_html_ba78d143bf457ead.png" height="369" width="600"]]
41 -
42 -{{id name="I12.PLCProtocol_html_23533fd5bb81f4ab.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c3240b50b359cc.png||alt="12.PLC Protocol_html_23533fd5bb81f4ab.png" height="389" width="600"]]
43 -
44 -Extended tag name
45 -
46 -Address range for the extended tag.
47 -
48 -**Communication Settings**
49 -
50 -Enable HMI Ethernet in [Project Settings];
51 -
52 -{{id name="I12.PLCProtocol_html_43b671f18153910d.png-11"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
53 -
54 -Set PLC IP in [Device IP] settings;
55 -
56 -{{id name="I12.PLCProtocol_html_f848736ec68b125.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_74e58fa452e39f04.png||alt="12.PLC Protocol_html_f848736ec68b125.png" height="191" width="554"]]
57 -
58 -**Cable Wiring**
59 -
60 -{{id name="I12.PLCProtocol_html_2297240b57346b2a.png-8"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]