Last modified by Devin Chen on 2025/02/22 11:16

From version 33.1
edited by Joe
on 2024/11/28 18:45
Change comment: There is no comment for this version
To version 40.1
edited by Hunter
on 2025/01/09 09:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.Hunter
Content
... ... @@ -3,28 +3,26 @@
3 3  The table below shows the maximum number of communications configured for the general protocol, Free Tag Protocol and CodeSys V3 Protocol on each series model.
4 4  **~ (~*~*Only HMI V2.0 System supports Free Tag Protocol and CodeSys V3 Protocol~*~*)**
5 5  
6 -|=HMI Series|=General Protocol|=FreeTags Protocol|=CodeSys V3 Protocol
7 -|=General 3000 Series|16|N/A|N/A
8 -|=General 8000 Series|24|4|N/A
9 -|=General 9000 Series|32|N/A|N/A
10 -|=PI3000i Series|16|N/A|N/A
6 +|=HMI Series|=General Protocol
7 +|=General 3000 Series|16
8 +|=General 8000 Series|24
9 +|=General 9000 Series|32
10 +|=PI3000i Series|16
11 11  |=PI3000ie Series
12 - (PI3043ieS-N)|16|2|N/A
12 + (PI3043ieS-N)|16
13 13  |=PI3000ie Series
14 - (other model)|N/A|N/A|N/A
15 -|= PI3070ig-O & PI3102ig-O|16|N/A|N/A
16 -|=PI3000ig Series
17 - (except -O models)|16|4|2
18 -|=PI8000ig Series|32|6|2
14 + (other model)|N/A
15 +|=PI3000ig Series|32
16 +|=PI8000ig Series|32
19 19  
20 20  = PIStudio Version Limit Differences for FreeTag protocol =
21 21  
22 22  (% style="width:1470px" %)
23 -|=(% style="width: 116px;" %)PIStudio Version|=(% colspan="2" style="width: 556px;" %)8.2.95.22092802|=(% colspan="2" style="width: 417px;" %)8.4.66.23102001|=(% colspan="2" style="width: 417px;" %)8.4.114.24061301
21 +|=(% style="width: 116px;" %)PIStudio Version|=(% colspan="2" style="width: 556px;" %)8.2.95.22092802|=(% colspan="2" style="width: 417px;" %)8.4.66.23102001|=(% colspan="2" style="width: 417px;" %)9.1.18.24122702
24 24  |=(% style="width: 116px;" %)Protocol|(% style="width:235px" %)Wecon LX6V FreeTag*|(% style="width:207px" %)3rd Party Manufacturer FreeTag*|(% style="width:205px" %)Wecon FreeTag Protocol(6C & 6V)*|(% style="width:212px" %)3rd Party Manufacturer FreeTag|(% style="width:212px" %)Wecon FreeTag Protocol(6C & 6V)|(% style="width:212px" %)3rd Party Manufacturer FreeTag
25 25  |=(% style="width: 116px;" %)PI3043ieS-N|(% style="width:235px" %)YES|(% style="width:207px" %)YES|(% style="width:205px" %)N/A|(% style="width:212px" %)N/A|(% style="width:212px" %)N/A|(% style="width:212px" %)N/A
26 -|=(% style="width: 116px;" %)PI3070ig-O(x)*, PI3102ig-O(x), PI3070ig-OH(x), PI3102ig-OH(x), |(% style="width:235px" %)YES|(% style="width:207px" %)YES|(% style="width:205px" %)N/A|(% style="width:212px" %)N/A|(% style="width:212px" %)N/A|(% style="width:212px" %)N/A
27 -|=(% style="width: 116px;" %)PI3070ig(x)*, PI3102ig(x),  PI3070ig-C(x), PI3102ig-C(x), PI3070ig-CH(x), PI3102ig-CH(x)|(% style="width:235px" %)YES|(% style="width:207px" %)YES|(% style="width:205px" %)YES|(% style="width:212px" %)YES|(% style="width:212px" %)YES|(% style="width:212px" %)YES
24 +|=(% style="width: 116px;" %)PI3070ig-O(x)*, PI3102ig-O(x), PI3070ig-OH(x), PI3102ig-OH(x), |(% style="width:235px" %)YES|(% style="width:207px" %)YES|(% style="width:205px" %)N/A|(% style="width:212px" %)N/A|(% style="width:212px" %)YES|(% style="width:212px" %)N/A
25 +|=(% style="width: 116px;" %)PI3070ig(x)*, PI3102ig(x),  PI3070ig-C(x), PI3102ig-C(x), PI3070ig-CH(x), PI3102ig-CH(x)|(% style="width:235px" %)YES|(% style="width:207px" %)YES|(% style="width:205px" %)YES|(% style="width:212px" %)YES|(% style="width:212px" %)YES|(% style="width:212px" %)N/A
28 28  |=(% style="width: 116px;" %)PI8000ig|(% style="width:235px" %)YES|(% style="width:207px" %)YES|(% style="width:205px" %)YES|(% style="width:212px" %)YES|(% style="width:212px" %)YES|(% style="width:212px" %)YES
29 29  
30 30  {{info}}
... ... @@ -49,7 +49,7 @@
49 49  |=(% style="width: 300px;" %)INOVANCE H5U FreeTag|(% style="width:155px" %)YES|(% style="width:171px" %)N/A|(% style="width:193px" %)YES(2.0)*|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
50 50  |=(% style="width: 300px;" %)OMRON NX/NJ|(% style="width:155px" %)YES|(% style="width:171px" %)N/A|(% style="width:193px" %)YES(2.0)*|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
51 51  |=(% style="width: 300px;" %)Rockwell CompactLogix|(% style="width:155px" %)YES|(% style="width:171px" %)N/A|(% style="width:193px" %)YES(2.0)*|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
52 -|=(% style="width: 300px;" %)Rockwell Micro850|(% style="width:155px" %)YES|(% style="width:171px" %)N/A|(% style="width:193px" %)YES(2.0)*|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
50 +|=(% style="width: 300px;" %)Rockwell Micro850|(% style="width:155px" %)YES|(% style="width:171px" %)N/A|(% style="width:193px" %)YES(2.0)*<sup>1</sup>|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
53 53  |=(% style="width: 300px;" %)SiemensS7-1200/S7-1500 FreeTag|(% style="width:155px" %)YES|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
54 54  |=(% style="width: 300px;" %)OPC UA Client|(% style="width:155px" %)YES|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
55 55  |=(% style="width: 300px;" %)OPC UA Server|(% style="width:155px" %)N/A|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
... ... @@ -75,5 +75,5 @@
75 75  
76 76  (% class="box infomessage" %)
77 77  (((
78 -Note: The above number is recommended number. The operating speed of HMI will be slow after exceeding the number.
76 +Note: The above number is recommended number. The operating speed of HMI may be slow after exceeding the number.
79 79  )))
XWiki.XWikiComments[0]
Author
... ... @@ -1,0 +1,1 @@
1 +xwiki:XWiki.Roy
Comment
... ... @@ -1,0 +1,1 @@
1 +Kenyence的自由标签要补上
Date
... ... @@ -1,0 +1,1 @@
1 +2024-12-10 11:19:27.277
Selection
... ... @@ -1,0 +1,1 @@
1 +BECKHOFF TwinCAT
State
... ... @@ -1,0 +1,1 @@
1 +SAFE
Target
... ... @@ -1,0 +1,1 @@
1 +PIStudio.PLC Protocol.Limitation of the Ethernet communication protocol.WebHome