Changes for page Mitsubishi
Last modified by Jett on 2025/01/16 09:26
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
- xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_183dee3a2f9d5a5a.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_1e9a9e29a46a1041.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_4856928ac03ccb79.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_7f29923ebcb670d1.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_9abc6f2f8ad89136.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_a2437897f85ae78.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ad7bac4c325df08d.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_dfbfdd586c855c47.png
Details
- Page properties
-
- Title
-
... ... @@ -1,0 +1,1 @@ 1 +Mitsubishi - Content
-
... ... @@ -1,0 +1,603 @@ 1 += {{id name="HMitsubishi"/}}**Mitsubishi** = 2 + 3 +== {{id name="HFX1S2C1N2C2NSeries"/}}**FX1S, 1N, 2N Series** == 4 + 5 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 6 + 7 +**HMI Settings** 8 + 9 +|**Item**|**Settings**|**Note** 10 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 11 +|Connection|RS422/RS485/RS232| 12 +|Baud rate|9600~~115200| 13 +|Data bit|7/8| 14 +|Parity|EVEN/Odd/None| 15 +|Stop bit|1/2| 16 +|PLC station No.|1~~255| 17 + 18 +**Address List** 19 + 20 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 22 +|Y|Y|Y o|0~~303237| 23 +|M|M|M d|0~~99999| 24 +|T|T|T d|0~~99999| 25 +|C|C|C d|0~~99999| 26 +|S|S|S d|0~~99999| 27 +|SM|SM|SM d|8000~~9999| 28 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 29 +|Y|Y|Y o|0~~303237| 30 +|M|M|M d|0~~99999| 31 +|T|T|T d|0~~99999| 32 +|C|C|C d|0~~199| 33 +|D|D|D d|0~~7999| 34 +|S|S|S d|0~~99999| 35 +|SD|SD|SD d|8000~~9999| 36 + 37 +**Cable Wiring** 38 + 39 +* **RS485** 40 + 41 +{{id name="I12.PLCProtocol_html_d4012bdeb4ce4aae.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ddcfa89a7e788c14.png||alt="12.PLC Protocol_html_d4012bdeb4ce4aae.png" height="244" width="394"]] 42 + 43 +{{id name="I12.PLCProtocol_html_4bf57ad8d44eacc4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_64f32195c6a29424.png||alt="12.PLC Protocol_html_4bf57ad8d44eacc4.png" height="244" width="394"]] 44 + 45 +* **RS422** 46 + 47 +{{id name="I12.PLCProtocol_html_f8a6bebc5792960d.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e27e979a8eaf8f17.png||alt="12.PLC Protocol_html_f8a6bebc5792960d.png" height="253" width="402"]] 48 + 49 +**✎Note:** COM3 only available in PI8000/PI9000 series. 50 + 51 +== {{id name="HFX3U2F3G2F3GASerial"/}}**FX3U/3G/3GA Serial** == 52 + 53 +**HMI Settings** 54 + 55 +|=**Item**|=**Settings**|=**Note** 56 +|Protocol|Mitsubishi FX3U/3G/3GA| 57 +|Connection|RS422| 58 +|Baud rate|9600~~115200| 59 +|Data bit|7/8| 60 +|Parity|EVEN/Odd/None| 61 +|Stop bit|1/2| 62 +|PLC station No.|1~~255| 63 + 64 +**Address List** 65 + 66 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 67 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 68 +|Y|Y|Y o|0~~303237| 69 +|M|M|M d|0~~99999| 70 +|T|T|T d|0~~99999| 71 +|C|C|C d|0~~99999| 72 +|S|S|S d|0~~99999| 73 +|SM|SM|SM d|8000~~9999| 74 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 75 +|Y|Y|Y o|0~~303237| 76 +|M|M|M d|0~~99999| 77 +|T|T|T d|0~~99999| 78 +|C|C|C d|0~~199| 79 +|D|D|D d|0~~7999| 80 +|S|S|S d|0~~99999| 81 +|SD|SD|SD d|8000~~9999| 82 + 83 +**Configure the communication protocol** 84 + 85 +{{id name="Iimage-20220831095222-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_87497ea9be28fa5.png||alt="image-20220831095222-1.png" height="735" width="616"]] 86 + 87 +{{id name="Iimage-20220831095743-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f1214e2436407de.png||alt="image-20220831095743-2.png" height="905" width="1038"]] 88 + 89 +**Wiring** 90 + 91 +{{id name="Iimage-20220831100314-6.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_feac72c6266d5c9f.png||alt="image-20220831100314-6.png" height="240" width="381"]] 92 + 93 +== {{id name="HFXNOPROTOCOL"/}}**FX NOPROTOCOL** == 94 + 95 +Mitsubishi FX3G-RS232-BD 96 + 97 +**HMI Settings** 98 + 99 +|=**Item**|=**Settings**|=**Note** 100 +|Protocol|Mitsubishi FX NOPROTOCOL| 101 +|Connection|RS232| 102 +|Baud rate|9600| 103 +|Data bit|7| 104 +|Parity|EVEN| 105 +|Stop bit|1| 106 +|PLC station No.|0| 107 + 108 +**Address List** 109 + 110 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 111 +|(% rowspan="8" %)Bit|X|X|X o|0~~303237| 112 +|Y|Y|Y o|0~~303237| 113 +|M|M|M d|0~~99999| 114 +|T|T|T d|0~~99999| 115 +|C|C|C d|0~~99999| 116 +|S|S|S d|0~~99999| 117 +|SM|SM|SM d|8000~~9999| 118 +|Lamp|Lamp|Lamp d|0~~0| 119 +|(% rowspan="8" %)Word|X|X|X o|0~~303237| 120 +|Y|Y|Y o|0~~303237| 121 +|M|M|M d|0~~99999| 122 +|T|T|T d|0~~99999| 123 +|C|C|C d|0~~199| 124 +|D|D|D d|0~~7999| 125 +|S|S|S d|0~~99999| 126 +|SD|SD|SD d|8000~~9999| 127 + 128 +**Configure the communication protocol** 129 + 130 +{{id name="I1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_468060edf3e40542.png||alt="1.png" height="706" width="909"]] 131 + 132 +{{id name="I2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d58ca6ee4453ebce.png||alt="2.png" height="706" width="909"]] 133 + 134 +**Wiring** 135 + 136 +{{id name="I3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png||alt="3.png" height="246" width="401"]] 137 + 138 +== {{id name="HFX3UEthernet"/}}**FX3U Ethernet** == 139 + 140 +Mitsubishi FX3U series PLC 141 + 142 +**HMI Settings** 143 + 144 +|Items|Settings|Note 145 +|Protocol|Mitsubishi FX3U Ethernet| 146 +|Connection|Ethernet| 147 +|Port No.|5009|Must be the same as the PLC setting 148 +|PLC station No.|0| 149 + 150 +**Address List** 151 + 152 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 153 +|(% rowspan="7" %)Bit|X|X|X OOO|0~~377| 154 +|Y|Y|Y OOO|0~~377| 155 +|M|M|M DDDD|0~~7679| 156 +|SM|SM|SM DDDD|8000~~8511| 157 +|S|S|S DDDD|0~~4095| 158 +|TS|TS|TS DDD|0~~511| 159 +|CS|CS|CS DDD|0~~255| 160 +|(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199| 161 +|TN|TN|TN DDD|0~~511| 162 +|D|D|D DDDD|0~~7999| 163 +|SD|SD|SD DDDD|8000~~8511| 164 +|R|R|R DDDDD|0~~32767| 165 + 166 +**Ethernet Module Settings** 167 + 168 +FX3U-ENET-L module configuration 169 + Set up the FX3U-ENET-L Ethernet module settings as follows. 170 + Select the module location, which in this document is Module 0. 171 + 172 +{{id name="Iimage-20221115140802-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_949d5d77c1d9cf1e.png||alt="image-20221115140802-1.png" height="573" width="706"]] 173 + 174 +Select "Operational setting" to enter the following screen. 175 + 176 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 177 + 178 +{{id name="Iimage-20221115142728-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_dfbfdd586c855c47.png||alt="image-20221115142728-4.png" height="573" width="706"]] 179 + 180 +Select "Open setting" to enter the setting interface, the settings are as follows. 181 + 182 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 183 + 184 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 185 + 186 +{{id name="Iimage-20221115142945-5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7c01ac15090fcc5b.png||alt="image-20221115142945-5.png" height="549" width="706"]] 187 + 188 +Click on "transter setup" - "PC side I/F setting", see the following figure. 189 + 190 +After setting, the first download must use the programming cable, as shown in the figure; after that, can 191 + 192 +use the IP set in the "Ethernet board" to communicate directly with the network cable. 193 + 194 +{{id name="Iimage-20221115143341-6.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221115143341-6.png" height="426" width="712"]] 195 + 196 +Read and write data from the Ethernet module 197 + 198 +{{id name="Iimage-20221115143703-7.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_690b3e57b29cfd4b.png||alt="image-20221115143703-7.png" height="549" width="706"]] 199 + 200 +Set "Transter setup" to COM communication, and read or write operation as shown below 201 + 202 +{{id name="Iimage-20221115143809-8.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_b317253742f7151.png||alt="image-20221115143809-8.png" height="549" width="706"]] 203 + 204 +**PLC Settings (GX Works 2)** 205 + 206 +Create a blank FX5U project 207 + 208 +Find Current Connection in the navigation 209 + 210 +{{id name="Iimage-20221115144335-9.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d2a46ba9c005cf38.png||alt="image-20221115144335-9.png" height="422" width="706"]] 211 + 212 +Select Connection Channel List 213 + 214 +Select Ethernet board communication 215 + 216 +{{id name="Iimage-20221115144824-10.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8f49721a3e5b0ef9.png||alt="image-20221115144824-10.png" height="421" width="705"]] 217 + 218 +Select Ethernet Module 219 + Set the IP address of the PLC 220 + 221 +{{id name="Iimage-20221115145228-11.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1e9a9e29a46a1041.png||alt="image-20221115145228-11.png" height="674" width="708"]] 222 + 223 +Read or write PLC data, in this document is read 224 + 225 +{{id name="Iimage-20221115145553-12.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e3d629103727a423.png||alt="image-20221115145553-12.png" height="424" width="711"]] 226 + 227 +{{id name="Iimage-20221115145559-13.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7f29923ebcb670d1.png||alt="image-20221115145559-13.png" height="424" width="711"]] 228 + 229 +**HMI Communication Setting** 230 + 231 +{{id name="Iimage-20221115150003-14.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_11364c6da9a4fd72.png||alt="image-20221115150003-14.png" height="425" width="712"]] 232 + 233 +{{id name="Iimage-20221115150235-15.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4c73e8982af3231.png||alt="image-20221115150235-15.png" height="427" width="713"]] 234 + 235 +{{id name="Iimage-20221115145559-13.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7f29923ebcb670d1.png||alt="image-20221115145559-13.png" height="424" width="711"]] 236 + 237 +**HMI Communication Setting** 238 + 239 +{{id name="Iimage-20221115150003-14.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_11364c6da9a4fd72.png||alt="image-20221115150003-14.png" height="425" width="712"]] 240 + 241 +{{id name="Iimage-20221115150235-15.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4c73e8982af3231.png||alt="image-20221115150235-15.png" height="427" width="713"]] 242 + 243 +== {{id name="HFX5USerial"/}}**FX5U Serial** == 244 + 245 +Mitsubishi FX5U series PLC 246 + 247 +**HMI Settings** 248 + 249 +|**Item**|**Settings**|**Note** 250 +|Protocol|Mitsubishi FX5U| 251 +|Connection|RS422/RS485| 252 +|Baud rate|9600| 253 +|Data bit|7| 254 +|Parity|Odd| 255 +|Stop bit|1| 256 +|PLC station No.|1~~255|Need to be the same as PLC settings 257 + 258 +**Address List** 259 + 260 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 261 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 262 +|Y|Y|Y o|0~~303237| 263 +|M|M|M d|0~~99999| 264 +|B|B|B h|0~~7FFF| 265 +|F|F|F d|0~~32767| 266 +|SB|SB|SB h|0~~7FFF| 267 +|TS|TS|TS d|0~~1023| 268 +|TC|TC|TC d|0~~1023| 269 +|STS|STS|STS d|0~~1023| 270 +|STC|STC|STS d|0~~1023| 271 +|CS|CS|CS d|0~~1023| 272 +|CC|CC|CC d|0~~1023| 273 +|SM|SM|SM d|0~~9999| 274 +|L|L|L d|0~~32767| 275 +|S|S|S d|0~~4095| 276 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 277 +|TN|TN|TN d|0~~1023| 278 +|STN|STN|STN d|0~~1023| 279 +|CN|CN|CN d|0~~1023| 280 +|R|R|R d|0~~32767| 281 +|SW|SW|SW h|0~~7FFF| 282 +|Z|Z|Z d|0~~23| 283 +|D|D|D d|0~~7999| 284 +|SD|SD|SD d|0~~11999| 285 + 286 +**PLC Settings (GX Works 3)** 287 + 288 +Create a blank FX5U project 289 + 290 +Find the 485 serial port module in the system navigation bar and double click to enter the settings. 291 + 292 +{{id name="I12.PLCProtocol_html_5c9cb13fac1e6c93.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a2437897f85ae78.png||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 293 + 294 +Select protocol in the setting item, and set parameters. 295 + 296 +{{id name="I12.PLCProtocol_html_de942589ca070228.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e13b2569bc879dc9.png||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 297 + 298 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 299 + 300 +{{id name="I12.PLCProtocol_html_387ec7d00b5feb59.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7a585c2e05785534.png||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 301 + 302 +Click the [Apply] button to finish the setting. 303 + 304 +Click download and select the items as below, then click [execute] to download the configuration to PLC. 305 + 306 +{{id name="I12.PLCProtocol_html_cdef1c5ec8cc2105.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_24ac3c2c904fdd5a.png||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 307 + 308 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 309 + 310 +Done. 311 + 312 +**Cable Wiring** 313 + 314 +* **RS485** 315 + 316 +{{id name="I12.PLCProtocol_html_d4012bdeb4ce4aae.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ddcfa89a7e788c14.png||alt="12.PLC Protocol_html_d4012bdeb4ce4aae.png" height="244" width="394"]] 317 + 318 +{{id name="I12.PLCProtocol_html_4bf57ad8d44eacc4.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_64f32195c6a29424.png||alt="12.PLC Protocol_html_4bf57ad8d44eacc4.png" height="244" width="394"]] 319 + 320 +* **RS422** 321 + 322 +{{id name="I12.PLCProtocol_html_f8a6bebc5792960d.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e27e979a8eaf8f17.png||alt="12.PLC Protocol_html_f8a6bebc5792960d.png" height="253" width="402"]] 323 + 324 +**✎Note:** COM3 only available in PI8000/PI9000 series. 325 + 326 +== {{id name="HL02CPUPort"/}}**L02 CPU Port** == 327 + 328 +Mitsubishi L02 series CPU built-in serial port. 329 + 330 +**HMI Settings** 331 + 332 +|=**Item**|=**Settings**|=**Note** 333 +|Protocol|Mitsubishi L02 CPU Port| 334 +|Connection|RS422| 335 +|Baud rate|115200| 336 +|Data bit|8| 337 +|Parity|Odd| 338 +|Stop bit|1| 339 +|PLC station No.|1~~255|Need to be the same as PLC settings 340 + 341 +**Address List** 342 + 343 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 344 +|Bit|X|X|X h|0~~FFFF| 345 +|Bit|Y|Y|Y h|0~~FFFF| 346 +|Bit|M|M|M d|0~~9999| 347 +|Bit|L|L|L d|0~~9999| 348 +|Bit|F|F|F d|0~~9999| 349 +|Bit|B|B|B h|0~~FFFF| 350 +|Bit|V|V|V d|0~~2047| 351 +|Bit|TC|TC|TC d|0~~9999| 352 +|Bit|SS|SS|SS d|0~~9999| 353 +|Bit|SC|SC|SC d|0~~9999| 354 +|Bit|CS|CS|CS d|0~~9999| 355 +|Bit|CC|CC|CC d|0~~9999| 356 +|Bit|SB|SB|SB h|0~~FFFF| 357 +|Bit|SM|SM|SM d|0~~2047| 358 +|Bit|STS|STS|STS d|0~~1023| 359 +|Bit|S|S|S d|0~~9999| 360 +|Bit|DX|DX|DX h|0~~FFFF| 361 +|Bit|DY|DY|DY h|0~~FFFF| 362 +|Bit|TS|TS|TS d|0~~9999| 363 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 364 +|Word|W|W|W h|0~~FFFF| 365 +|Word|TN|TN|TN d|0~~99999| 366 +|Word|SN|SN|SN d|0~~99999| 367 +|Word|CN|CN|CN d|0~~99999| 368 +|Word|R|R|R d|0~~99999| 369 +|Word|SW|SW|SW h|0~~FFFF| 370 +|Word|Z|Z|Z d|0~~99999| 371 +|Word|ZR|ZR|ZR h|0~~FFFF| 372 +|Word|D|D|D d|0~~99999| 373 + 374 +**Communication Settings** 375 + 376 +{{id name="Iimage-20220831105732-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d08c69b880471768.png||alt="image-20220831105732-3.png" height="735" width="616"]] 377 + 378 +{{id name="Iimage-20220831110004-5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6479028a3958c09.png||alt="image-20220831110004-5.png" height="905" width="1038"]] 379 + 380 +**Cable Wiring** 381 + 382 +{{id name="Iimage-20220831105542-2.png"/}}{{id name="Iimage-20220831105529-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_183dee3a2f9d5a5a.png||alt="image-20220831105542-2.png" height="172" width="226"]] [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_679c6b6b2dc84d90.png||alt="image-20220831105529-1.png" height="228" width="492"]] 383 + 384 +Pin Definition Diagram 385 + 386 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FV-BOX2FV-Net2FTraining2F12520Communication2FWebHome2Fimage-20220825160820-4.png3Frev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220825160820-4.png?rev=1.1||alt="image-20220825160820-4.png" height="38" width="76"]] 387 + 388 +== {{id name="HL02CPUMELSEC28Ethernet29"/}}**L02 CPU MELSEC(Ethernet)** == 389 + 390 +Mitsubishi Q series CPU built-in Ethernet port. 391 + 392 +**HMI Settings** 393 + 394 +|**Items**|**Settings**|**Note** 395 +|Protocol|MITSUBISHI L02 CPU MELSEC| 396 +|Connection|Ethernet| 397 +|Port No.|1025|Must be the same as the PLC setting 398 +|PLC station No.|0|Must be the same as the PLC setting 399 + 400 +**Address List** 401 + 402 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 403 +|Bit|X|X|X h|0~~FFFF| 404 +|Bit|Y|Y|Y h|0~~FFFF| 405 +|Bit|M|M|M d|0~~9999| 406 +|Bit|L|L|L d|0~~9999| 407 +|Bit|F|F|F d|0~~9999| 408 +|Bit|B|B|B h|0~~FFFF| 409 +|Bit|V|V|V d|0~~2047| 410 +|Bit|TC|TC|TC d|0~~9999| 411 +|Bit|SS|SS|SS d|0~~9999| 412 +|Bit|SC|SC|SC d|0~~9999| 413 +|Bit|CS|CS|CS d|0~~9999| 414 +|Bit|CC|CC|CC d|0~~9999| 415 +|Bit|SB|SB|SB h|0~~FFFF| 416 +|Bit|SM|SM|SM d|0~~2047| 417 +|Bit|STS|STS|STS d|0~~1023| 418 +|Bit|S|S|S d|0~~9999| 419 +|Bit|DX|DX|DX h|0~~FFFF| 420 +|Bit|DY|DY|DY h|0~~FFFF| 421 +|Bit|TS|TS|TS d|0~~9999| 422 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 423 +|Word|W|W|W h|0~~FFFF| 424 +|Word|TN|TN|TN d|0~~99999| 425 +|Word|SN|SN|SN d|0~~99999| 426 +|Word|CN|CN|CN d|0~~99999| 427 +|Word|R|R|R d|0~~99999| 428 +|Word|SW|SW|SW h|0~~FFFF| 429 +|Word|Z|Z|Z d|0~~99999| 430 +|Word|ZR|ZR|ZR h|0~~FFFF| 431 +|Word|D|D|D d|0~~99999| 432 + 433 +**Communication Settings** 434 + 435 +Enable HMI Ethernet in [Project Settings]; 436 + 437 +{{id name="I12.PLCProtocol_html_43b671f18153910d.png-1"/}} [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]] 438 + 439 +Set PLC IP in [Device IP] settings; 440 + 441 +{{id name="I12.PLCProtocol_html_38189fae42f6caa7.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_376def31824aaed1.png||alt="12.PLC Protocol_html_38189fae42f6caa7.png" height="206" width="600"]] 442 + 443 +**PLC Settings (GX Works2 )** 444 + 445 +Create a project 446 + 447 +Set PLC IP, subnet mask and gateway; 448 + 449 +Select [Binary Code] as communication data code; 450 + 451 +{{id name="Iimage-20221108202109-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8c67f9236cf3c782.png||alt="image-20221108202109-2.png" height="636" width="732"]] 452 + 453 +Set PLC port number, for example 1025 454 + 455 +{{id name="I12.PLCProtocol_html_8d0d1a22d388f70b.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4fafc6de7980df7a.png||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 456 + 457 +Save settings; 458 + 459 +Download project into PLC device; 460 + 461 +Restart PLC device; 462 + 463 +**Cable Wiring** 464 + 465 +{{id name="I12.PLCProtocol_html_2297240b57346b2a.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 466 + 467 +== {{id name="HQJ71C24NMELSEC"/}}**QJ71C24N MELSEC** == 468 + 469 +Mitsubishi QJ71C24N communication module built-in serial port; 470 + 471 +**HMI Settings** 472 + 473 +|**Items**|**Settings**|**Note** 474 +|Protocol|MITSUBISHI QJ71 MELSEC| 475 +|Connection|422| 476 +|Baud rate|9600| 477 +|Data bit|8| 478 +|Parity|ODD| 479 +|Stop bit|1| 480 +|PLC station No.|1~~255|Need to be the same as PLC settings 481 + 482 +**Address List** 483 + 484 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 485 +|(% rowspan="19" %)Bit|X|X|X FFFF|0~~1FFF| 486 +|Y|Y|Y FFFF|0~~1FFF| 487 +|M|M|M DDDDD|0~~99999| 488 +|L|L|L DDDD|0~~8191| 489 +|F|F|F DDDD|0~~2047| 490 +|V|V|V DDDD|0~~2047| 491 +|B|B|B FFFF|0~~1FFF| 492 +|TS|TS|TS DDDD|0~~2047| 493 +|TC|TC|TC DDDD|0~~2047| 494 +|SS|SS|SS DDDD|0~~2047| 495 +|SC|SC|SC DDDD|0~~2047| 496 +|CS|CS|CS DDDD|0~~1023| 497 +|CC|CC|CC DDDD|0~~1023| 498 +|SB|SB|SB FFF|0~~7FF| 499 +|S|S|S D|0~~8191| 500 +|DX|DX|DX FFFF|0~~1FFF| 501 +|DY|DY|DY FFFF|0~~1FFF| 502 +|SM_|SM_|SM_ DDDD|8000~~9999| 503 +|SM|SM|SM DDDD|0~~2047| 504 +|(% rowspan="10" %)Word|SD|SD|SD DDDD|0~~2047| 505 +|D|D|D DDDDD|0~~12287| 506 +|W|W|W FFFF|0~~1FFF| 507 +|TN|TN|TN DDDD|0~~2047| 508 +|SN|SN|SN DDDD|0~~2047| 509 +|CN|CN|CN DDDD|0~~1023| 510 +|R|R|R DDDDD|0~~32767| 511 +|SW|SW|SW FFF|0~~7FF| 512 +|Z|Z|Z D|0~~15| 513 +|ZR|ZR|ZR FFFFF|0~~FE7FF| 514 + 515 +**Communication Settings** 516 + 517 +{{id name="Iimage-20221109135738-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_6513d4083293f50e.png||alt="image-20221109135738-1.png" height="574" width="540"]] 518 + 519 +{{id name="Iimage-20221109140016-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4856928ac03ccb79.png||alt="image-20221109140016-3.png" height="706" width="909"]] 520 + 521 +Pin Definition Diagram 522 + 523 +{{id name="Iimage-20221109140406-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_708b4368ae664f84.png||alt="image-20221109140406-4.png" height="247" width="397"]] 524 + 525 +== {{id name="HQJ71E71MELSEC"/}}**QJ71E71 MELSEC** == 526 + 527 +Mitsubishi QJ71E71 Ethernet communication module; 528 + 529 +**HMI Settings** 530 + 531 +|**Items**|**Settings**|**Note** 532 +|Protocol|MITSUBISHI QJ71E71 MELSEC| 533 +|Connection|Ethernet| 534 +|Port No.|1025|Must be the same as the PLC setting 535 +|PLC station No.|0|Must be the same as the PLC setting 536 + 537 +**Address List** 538 + 539 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 540 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 541 +|Y|Y|Y h|0~~1FFF| 542 +|M|M|M d|0~~99999| 543 +|L|L|L d|0~~8191| 544 +|F|F|F d|0~~2047| 545 +|B|B|B h|0~~1FFF| 546 +|V|V|V d|0~~2047| 547 +|TS|TS|TS d|0~~2047| 548 +|TC|TC|TC d|0~~2047| 549 +|SS|SS|SS d|0~~2047| 550 +|SC|SC|SC d|0~~2047| 551 +|CS|CS|CS d|0~~1023| 552 +|CC|CC|CC d|0~~1023| 553 +|SB|SB|SB h|0~~7FF| 554 +|S|S|S d|0~~8191| 555 +|DX|DX|DX h|0~~1FFF| 556 +|DY|DY|DY h|0~~1FFF| 557 +|SM|SM|SM d|8000~~9999| 558 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| 559 +|D|D|D d|0~~12287| 560 +|W|W|W h|0~~1FFF| 561 +|TN|TN|TN d|0~~2047| 562 +|SN|SN|SN d|0~~2047| 563 +|CN|CN|CN d|0~~1023| 564 +|R|R|R d|0~~32767| 565 +|SW|SW|SW h|0~~7FF| 566 +|Z|Z|Z d|0~~15| 567 +|ZR|ZR|ZR h|0~~FE7FF| 568 + 569 +**HMI Communication Settings** 570 + 571 +1) Enable HMI Ethernet in [Project Settings]; 572 + 573 +{{id name="I12.PLCProtocol_html_43b671f18153910d.png-2"/}} [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]] 574 + 575 +2) Set PLC IP in [Device IP] settings 576 + 577 +{{id name="Iimage-20221119164628-1.png"/}};[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a672b85489bc3ccf.png||alt="image-20221119164628-1.png" height="502" width="646"]] 578 + 579 +**PLC Settings(GX Works2)** 580 + 581 +* Click [Ethernet/CC IE/MELSECNET]; 582 +* Please select [Ethernet] as network type; 583 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 584 +* Select [Online] as Mode; 585 +* {{id name="Iimage-20221119164958-2.png"/}}{{id name="I12.PLCProtocol_html_acd084d845da380e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_5299cbf3c8268344.png||alt="image-20221119164958-2.png" height="356" width="611"]] [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_cca6d562ae3a78f7.png||alt="12.PLC Protocol_html_acd084d845da380e.png" height="300" width="554"]] 586 +* Click [Operation setting] to set IP; 587 +* Select [Binary Code] as [Communication Data Code]; 588 +* {{id name="Iimage-20221119165129-3.png"/}}{{id name="I12.PLCProtocol_html_a972e671d2bb9150.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ad7bac4c325df08d.png||alt="image-20221119165129-3.png" height="381" width="611"]] [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_bbfa45d44f415527.png||alt="12.PLC Protocol_html_a972e671d2bb9150.png" height="304" width="553"]] 589 +* Click [Open setting] 590 +* Set protocol: TCP; 591 +* Set [unpassive] in [Open system]; 592 +* Set [receive] in [Fixed buffer]; 593 +* Set [procedure Exist] in [Fixed buffer communication]; 594 +* Disable [Pairing open]; 595 +* Set [No confirm] in [Existence confirmation]; 596 +* Host station port number: 5009; 597 +* {{id name="I12.PLCProtocol_html_f2c432006cdd2f9.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_9abc6f2f8ad89136.png||alt="12.PLC Protocol_html_f2c432006cdd2f9.png" height="220" width="553"]] Save settings; 598 +* {{id name="Iimage-20221119165342-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_143120787717f1e3.png||alt="image-20221119165342-4.png" height="387" width="620"]] 599 +* Download project into PLC and restart it 600 + 601 +**Cable Wiring** 602 + 603 +{{id name="I12.PLCProtocol_html_2297240b57346b2a.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_183dee3a2f9d5a5a.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.5 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_1e9a9e29a46a1041.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_4856928ac03ccb79.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.2 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_7f29923ebcb670d1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +106.2 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_9abc6f2f8ad89136.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +75.6 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_a2437897f85ae78.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ad7bac4c325df08d.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +47.6 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_dfbfdd586c855c47.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.7 KB - Content