-== **CP2E Series Serial ** == |
| 211 |
|
- |
| 212 |
|
-Supported device:CP2E series,CP2E-N20DT-D |
| 213 |
|
- |
| 214 |
|
-**HMI Settings** |
| 215 |
|
- |
| 216 |
|
-|=**Items**|=**Settings** |
| 217 |
|
-|Protocol|OMRON CJ TCP FINS Ethemet |
| 218 |
|
-|Connection|Ethernet |
| 219 |
|
-|Port No.|9600 |
| 220 |
|
-|Device No.|0 |
| 221 |
|
-|HMI No.|0 |
| 222 |
|
- |
| 223 |
|
-**2.1 Create new HMI project** |
| 224 |
|
- |
| 225 |
|
-Open PIStudio Software>>New Project, as shown in the figure below, set the touch screen project model and communication device type in sequence. |
| 226 |
|
- |
| 227 |
|
-(% style="text-align:center" %) |
| 228 |
|
-[[image:1765960573514-689.png]] |
| 229 |
|
- |
| 230 |
|
-==== **2.2 Config HMI communication settings** ==== |
| 231 |
|
- |
| 232 |
|
-(1) Select the protocol as CJ UDP FINS Ethernet, then set the right PLC IP and corresponding port. |
| 233 |
|
- |
| 234 |
|
-For example, in this case, PLC IP is 192.168.43.101. |
| 235 |
|
- |
| 236 |
|
-(% style="text-align:center" %) |
| 237 |
|
-[[image:1765960573516-574.png]] |
| 238 |
|
- |
| 239 |
|
- |
| 240 |
|
-1. Set the HMI IP as the same segment with PLC side. For this case, it is 192.168.43.212. |
| 241 |
|
- |
| 242 |
|
-(% style="text-align:center" %) |
| 243 |
|
-[[image:1765960573517-788.png]] |
| 244 |
|
- |
| 245 |
|
-1. Program the HMI screen and put PLC address. |
| 246 |
|
- |
| 247 |
|
- |
| 248 |
|
- |
| 249 |
|
-(% style="text-align:center" %) |
| 250 |
|
-[[image:1765960573518-279.png]] |
| 251 |
|
- |
| 252 |
|
-**2.3 Config PLC communication settings** |
| 253 |
|
- |
| 254 |
|
-(1) Using CX Programmer P9.72 or version above to connect the PLC. Click "PLC" on toolbar, select "auto online", select "CP1/CP2 built-in Ethernet online". |
| 255 |
|
- |
| 256 |
|
-[[image:1765960573518-306.png]] |
| 257 |
|
- |
| 258 |
|
- |
| 259 |
|
-(2) Select "Direct connection" on the pop-up window. After connecting, it will prompt whether to upload the PLC program automatically, this can be selected as user need. |
| 260 |
|
- |
| 261 |
|
-(% style="text-align:center" %) |
| 262 |
|
-[[image:1765960573519-579.png]] |
| 263 |
|
- |
| 264 |
|
-(3) After the connected successfully, upload the configuration settings in "Settings" from the program tree on the right side. |
| 265 |
|
- |
| 266 |
|
-(% style="text-align:center" %) |
| 267 |
|
-[[image:1765960573519-497.png||height="340" width="189"]] |
| 268 |
|
- |
| 269 |
|
-1. After opening the Settings , select the option "transfer from PLC" to upload the configuration information from the PLC. |
| 270 |
|
- |
| 271 |
|
-(% style="text-align:center" %) |
| 272 |
|
-[[image:1765960573520-894.png||height="566" width="526"]] |
| 273 |
|
- |
| 274 |
|
-Figure 2-8 |
| 275 |
|
- |
| 276 |
|
-1. On the built-in Ethernet(Last one tab from Settings), will see the IP address, Node number and other related information. Node number need to configured as 101, Node number does not exist in the option of 0. |
| 277 |
|
- |
| 278 |
|
-(% style="text-align:center" %) |
| 279 |
|
-[[image:1765960573520-855.png||height="554" width="515"]] |
| 280 |
|
- |
| 281 |
|
-1. We will see the corresponding information available on the corresponding FINS/TCP and FINS/UDP settings. |
| 282 |
|
- |
| 283 |
|
-(% style="text-align:center" %) |
| 284 |
|
-[[image:1765960573521-123.png]] |
| 285 |
|
- |
| 286 |
|
-(% style="text-align:center" %) |
| 287 |
|
-[[image:1765960573521-815.png]] |
| 288 |
|
- |
| 289 |
|
- |
| 290 |
|
-**3.Notice** |
| 291 |
|
- |
| 292 |
|
-(1) The number of Ethernet nodes of Omron CP2E PLC is not set as 0 but can only start from 1. If the number of nodes is 0, the IP settings of PLC may be invalid and cannot be pinged through PC command window; |
| 293 |
|
- |
| 294 |
|
-(2) After config the parameters of Ethernet, it will take effect only after power off and restart; |
| 295 |
|
- |
| 296 |
|
-(3) When multiple PLCs communicate simultaneously, try to ensure that the port numbers are not duplicated. |
| 297 |
|
- |
| 298 |
298 |
== {{id name="HEC55Protocol"/}}**EC55 Protocol** == |
| 299 |
299 |
|
| 300 |
300 |
Supported device: EC55 temperature instrument |