Changes for page Omron

Last modified by Jett on 2024/10/23 20:42

From version 35.1
edited by Devin Chen
on 2023/09/12 15:03
Change comment: There is no comment for this version
To version 46.1
edited by Jett
on 2024/09/10 10:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.DevinChen
1 +XWiki.2454238480
Content
... ... @@ -1,6 +1,6 @@
1 1  = {{id name="HOmron"/}}**Omron** =
2 2  
3 -== **CJ TCP FINS Ethemet** ==
3 +== **CJ2M Series Ethemet** ==
4 4  
5 5  Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21
6 6  
... ... @@ -13,8 +13,61 @@
13 13  |Device No.|0
14 14  |HMI No.|0
15 15  
16 -(% id="cke_bm_1048S" style="display:none" %)** **(%%)**Configure the communication protocol**
16 +(% id="cke_bm_1048S" style="display:none" %)** **
17 17  
18 +**Address List**
19 +
20 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
21 +|(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999|
22 +|W|W|W d|0~~99999|
23 +|D|D|D d|0~~99999|
24 +|H|H|H d|0~~99999|
25 +|A|A|A d|0~~99999|
26 +|T|T|T h|0~~99999|
27 +|CF|CF|CF d|0~~99999|
28 +|FF|FF|FF d|0~~99999|
29 +|C|C|C d|0~~99999|
30 +|EM0|EM0|EM0 d|0~~99999|
31 +|EM1|EM1|EM1 d|0~~99999|
32 +|EM2|EM2|EM2 d|0~~99999|
33 +|EM3|EM3|EM3 d|0~~99999|
34 +|EM4|EM4|EM4 d|0~~99999|
35 +|EM5|EM5|EM5 h|0~~99999|
36 +|EM6|EM6|EM6 d|0~~99999|
37 +|EM7|EM7|EM7 d|0~~99999|
38 +|EM8|EM8|EM8 d|0~~99999|
39 +|EM9|EM9|EM9 d|0~~99999|
40 +|EMA|EMA|EMA d|0~~99999|
41 +|EMB|EMB|EMB d|0~~99999|
42 +|EMC|EMC|EMC d|0~~99999|
43 +|Lamp|Lamp|Lamp d|0~~0|
44 +|(% colspan="1" rowspan="24" %)Word|CIO|CIO|CIO d|0~~99999|
45 +|W|W|W d|0~~99999|
46 +|D|D|D d|0~~99999|
47 +|H|H|H d|0~~99999|
48 +|A|A|A d|0~~99999|
49 +|T|T|T h|0~~99999|
50 +|CF|CF|CF d|0~~99999|
51 +|FF|FF|FF d|0~~99999|
52 +|C|C|C d|0~~99999|
53 +|EM0|EM0|EM0 d|0~~99999|
54 +|EM1|EM1|EM1 d|0~~99999|
55 +|EM2|EM2|EM2 d|0~~99999|
56 +|EM3|EM3|EM3 d|0~~99999|
57 +|EM4|EM4|EM4 d|0~~99999|
58 +|EM5|EM5|EM5 h|0~~99999|
59 +|EM6|EM6|EM6 d|0~~99999|
60 +|EM7|EM7|EM7 d|0~~99999|
61 +|EM8|EM8|EM8 d|0~~99999|
62 +|EM9|EM9|EM9 d|0~~99999|
63 +|EMA|EMA|EMA d|0~~99999|
64 +|EMB|EMB|EMB d|0~~99999|
65 +|EMC|EMC|EMC d|0~~99999|
66 +|IR|IR|IR d|0~~99999|
67 +|DR|DR|DR d|0~~99999|
68 +
69 +**Configure the communication protocol**
70 +
18 18  {{id name="Iimage-20220830143348-1.png"/}}
19 19  
20 20  (% style="text-align:center" %)
... ... @@ -53,21 +53,44 @@
53 53  [[image:WeCom Screenshot_20230828090604.png]]
54 54  
55 55  
56 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.**
57 57  
111 +
58 58  (% style="text-align:center" %)
59 59  [[image:WeCom.png]]
60 60  
115 +**Cable Wiring**
61 61  
117 +Pin Definition Diagram
118 +
119 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-3"/}}
120 +
121 +(% style="text-align:center" %)
122 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
123 +
124 +== {{id name="HCS128CP1E2FCP1H29"/}}**CP1E Series Serial ** ==
125 +
126 +Supported device: OMRON CS1(CP1E/CP1H)
127 +
128 +**HMI Settings**
129 +
130 +|=**Items**|=**Settings**|=**Note**
131 +|Protocol|OMRON CS1(CP1E/CP1H)|
132 +|Connection|RS232 (9600, 2, 7, EVEN)|
133 +|Port No.|None|
134 +|PLC station No.|0|
135 +
136 +**Address List**
137 +
62 62  |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
63 -|(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999|
139 +|(% colspan="1" rowspan="22" %)Bit|CIO|CIO|CIO d|0~~99999|
64 64  |W|W|W d|0~~99999|
65 65  |D|D|D d|0~~99999|
66 66  |H|H|H d|0~~99999|
67 67  |A|A|A d|0~~99999|
68 -|T|T|T h|0~~99999|
144 +|TF|T|T h|0~~99999|
69 69  |CF|CF|CF d|0~~99999|
70 -|FF|FF|FF d|0~~99999|
146 +|T|FF|FF d|0~~99999|
71 71  |C|C|C d|0~~99999|
72 72  |EM0|EM0|EM0 d|0~~99999|
73 73  |EM1|EM1|EM1 d|0~~99999|
... ... @@ -82,15 +82,13 @@
82 82  |EMA|EMA|EMA d|0~~99999|
83 83  |EMB|EMB|EMB d|0~~99999|
84 84  |EMC|EMC|EMC d|0~~99999|
85 -|Lamp|Lamp|Lamp d|0~~0|
86 -|(% colspan="1" rowspan="24" %)Word|CIO|CIO|CIO d|0~~99999|
161 +|(% colspan="1" rowspan="23" %)Word|CIO|CIO|CIO d|0~~99999|
87 87  |W|W|W d|0~~99999|
88 88  |D|D|D d|0~~99999|
89 89  |H|H|H d|0~~99999|
90 90  |A|A|A d|0~~99999|
91 91  |T|T|T h|0~~99999|
92 -|CF|CF|CF d|0~~99999|
93 -|FF|FF|FF d|0~~99999|
167 +|CIO|CF|CF d|0~~99999|
94 94  |C|C|C d|0~~99999|
95 95  |EM0|EM0|EM0 d|0~~99999|
96 96  |EM1|EM1|EM1 d|0~~99999|
... ... @@ -108,76 +108,6 @@
108 108  |IR|IR|IR d|0~~99999|
109 109  |DR|DR|DR d|0~~99999|
110 110  
111 -**Cable Wiring**
112 -
113 -Pin Definition Diagram
114 -
115 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-3"/}}
116 -
117 -(% style="text-align:center" %)
118 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
119 -
120 -== {{id name="HCS128CP1E2FCP1H29"/}}**CS1(CP1E/CP1H)** ==
121 -
122 -Supported device: OMRON CS1(CP1E/CP1H)
123 -
124 -**HMI Settings**
125 -
126 -|=**Items**|=**Settings**|=**Note**
127 -|Protocol|OMRON CS1(CP1E/CP1H)|
128 -|Connection|RS232 (9600, 2, 7, EVEN)|
129 -|Port No.|None|
130 -|PLC station No.|0|
131 -
132 -**Address List**
133 -
134 -|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
135 -|Bit|CIO|CIO|CIO d|0~~99999|
136 -|Bit|W|W|W d|0~~99999|
137 -|Bit|D|D|D d|0~~99999|
138 -|Bit|H|H|H d|0~~99999|
139 -|Bit|A|A|A d|0~~99999|
140 -|Bit|TF|T|T h|0~~99999|
141 -|Bit|CF|CF|CF d|0~~99999|
142 -|Bit|T|FF|FF d|0~~99999|
143 -|Bit|C|C|C d|0~~99999|
144 -|Bit|EM0|EM0|EM0 d|0~~99999|
145 -|Bit|EM1|EM1|EM1 d|0~~99999|
146 -|Bit|EM2|EM2|EM2 d|0~~99999|
147 -|Bit|EM3|EM3|EM3 d|0~~99999|
148 -|Bit|EM4|EM4|EM4 d|0~~99999|
149 -|Bit|EM5|EM5|EM5 h|0~~99999|
150 -|Bit|EM6|EM6|EM6 d|0~~99999|
151 -|Bit|EM7|EM7|EM7 d|0~~99999|
152 -|Bit|EM8|EM8|EM8 d|0~~99999|
153 -|Bit|EM9|EM9|EM9 d|0~~99999|
154 -|Bit|EMA|EMA|EMA d|0~~99999|
155 -|Bit|EMB|EMB|EMB d|0~~99999|
156 -|Bit|EMC|EMC|EMC d|0~~99999|
157 -|Word|CIO|CIO|CIO d|0~~99999|
158 -|Word|W|W|W d|0~~99999|
159 -|Word|D|D|D d|0~~99999|
160 -|Word|H|H|H d|0~~99999|
161 -|Word|A|A|A d|0~~99999|
162 -|Word|T|T|T h|0~~99999|
163 -|Word|CIO|CF|CF d|0~~99999|
164 -|Word|C|C|C d|0~~99999|
165 -|Word|EM0|EM0|EM0 d|0~~99999|
166 -|Word|EM1|EM1|EM1 d|0~~99999|
167 -|Word|EM2|EM2|EM2 d|0~~99999|
168 -|Word|EM3|EM3|EM3 d|0~~99999|
169 -|Word|EM4|EM4|EM4 d|0~~99999|
170 -|Word|EM5|EM5|EM5 h|0~~99999|
171 -|Word|EM6|EM6|EM6 d|0~~99999|
172 -|Word|EM7|EM7|EM7 d|0~~99999|
173 -|Word|EM8|EM8|EM8 d|0~~99999|
174 -|Word|EM9|EM9|EM9 d|0~~99999|
175 -|Word|EMA|EMA|EMA d|0~~99999|
176 -|Word|EMB|EMB|EMB d|0~~99999|
177 -|Word|EMC|EMC|EMC d|0~~99999|
178 -|Word|IR|IR|IR d|0~~99999|
179 -|Word|DR|DR|DR d|0~~99999|
180 -
181 181  **Configure the communication protocol**
182 182  
183 183  {{id name="Iimage-20220902153118-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4acef6476c6f9de3.png||alt="image-20220902153118-1.png" height="735" width="616"]]
... ... @@ -260,7 +260,7 @@
260 260  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
261 261  * {{id name="I12.PLCProtocol_html_d428cad280fdefb3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f434f58797d3c0da.png||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]] Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
262 262  
263 -== {{id name="HNXEtherNet2FIP"/}}**NX EtherNet/IP** ==
267 +== {{id name="HNXEtherNet2FIP"/}}**Ethernet/IP (NX/NJ Serirs)** ==
264 264  
265 265  Supported series: Omron NX/NJ series
266 266  
... ... @@ -272,6 +272,26 @@
272 272  |Port No.|44818|
273 273  |PLC station No.|1|
274 274  
279 +**Address list**
280 +
281 +|Data type|Data format in PIStudio|Memo
282 +|BOOL|bit|
283 +|Byte|16-bit BCD,HEX,Binary,Unsigned|8-bit
284 +|SInt|16-bit BCD,HEX,Binary,Signed|8-bit
285 +|USInt|16-bit BCD,HEX,Binary,Unsigned|8-bit
286 +|Word|16-bit BCD,HEX,Binary,Unsigned|16-bit
287 +|Int|16-bit BCD,HEX,Binary,Signed|16-bit
288 +|UInt|16-bit BCD,HEX,Binary,Unsigned|16-bit
289 +|DWord|32-bit BCD, Hex, Binary, Unsigned|32-bit
290 +|DInt|32-bit BCD, Hex, Binary, Signed|32-bit
291 +|Real|32-bit Float|32-bit
292 +|UDInt|32-bit BCD, Hex, Binary, Unsigned|32-bit
293 +|LInt|64-bit Signed|64-bit
294 +|ULInt|64-bit USigned|64-bit
295 +|LWord|64-bit USigned|64-bit
296 +|LRea|64-bit Float|64-bit
297 +|Array|All of the above types|
298 +
275 275  **Instruction**
276 276  
277 277  1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
... ... @@ -278,45 +278,49 @@
278 278  
279 279  2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed.
280 280  
281 -{{id name="I12.PLCProtocol_html_4156caf6f116c570.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1275dbbb73675c45.png||alt="12.PLC Protocol_html_4156caf6f116c570.png" height="277" width="600"]]
305 +(% style="text-align:center" %)
306 +[[image:1725933697098-418.png]]
282 282  
283 283  **Export labels from Sysmac Studio**
284 284  
285 285  Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables];
286 286  
287 -{{id name="I12.PLCProtocol_html_26f91dee66c723e9.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4d41889d12980317.png||alt="12.PLC Protocol_html_26f91dee66c723e9.png" height="276" width="600"]]
312 +(% style="text-align:center" %)
313 +[[image:1725933727638-698.png]]
288 288  
289 -Launch PIStudio, in [Communication] Settings add Omron NX Ethernet/IP protocol;
315 +[[image:1725933619328-454.png]]
290 290  
291 -Click [Label manage];
317 +Create a .CSV file,and Paste the [CX-Designer] into it.
292 292  
293 -{{id name="I12.PLCProtocol_html_cd38d2d0c5187f6b.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c02902d35021dbd.png||alt="12.PLC Protocol_html_cd38d2d0c5187f6b.png" height="276" width="600"]]
319 +(% style="text-align:center" %)
320 +[[image:1725933782144-300.png]]
294 294  
295 -Click [Import labels] and then select the file exported in step 1;
322 +Launch PIStudio, in [Communication] Settings add [Omron Ethernet/IP (NX/NJ Serirs)] protocol;
296 296  
297 -{{id name="I12.PLCProtocol_html_52bd5da678bef9b4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_31ee4b3995e48a09.png||alt="12.PLC Protocol_html_52bd5da678bef9b4.png" height="403" width="600"]]
324 +[[image:1725933826453-416.png]]
298 298  
299 -The Import Status field shows the result, click [OK] to finish importing address labels;
326 +Click [Label manage];Click [Import Tags form file] and then Choose the .CSV file you need;
300 300  
301 -{{id name="I12.PLCProtocol_html_7f0465a589b98912.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_2e9eb22f4eb0faef.png||alt="12.PLC Protocol_html_7f0465a589b98912.png" height="291" width="600"]]
328 +(% style="text-align:center" %)
329 +[[image:1725933926323-707.png]]
302 302  
331 +
303 303  **Communication Settings**
304 304  
305 -Enable HMI Ethernet in [Project Settings];
306 -
307 -{{id name="I12.PLCProtocol_html_43b671f18153910d.png-4"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
308 -
309 309  Set PLC IP in [Device IP] settings;
310 310  
311 -{{id name="I12.PLCProtocol_html_437cb087b36b5784.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_3b29b2c9873ab9cc.png||alt="12.PLC Protocol_html_437cb087b36b5784.png" height="330" width="600"]]
336 +(% style="text-align:center" %)
337 +[[image:1725934163105-489.png||height="99" width="241"]]
312 312  
313 -{{id name="I12.PLCProtocol_html_60ef71528a99abf5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c45114a482fa38f6.png||alt="12.PLC Protocol_html_60ef71528a99abf5.png" height="188" width="554"]]
314 314  
340 +(% style="text-align:center" %)
341 +[[image:1725934131262-239.png]]
342 +
315 315  **Cable Wiring**
316 316  
317 317  {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
318 318  
319 -== {{id name="HCV2FCJ1M2FCS1H"/}}**CV/CJ1M/CS1H** ==
347 +== {{id name="HCV2FCJ1M2FCS1H"/}}**CJ2M Series Serial ** ==
320 320  
321 321  **HMI Setting:**
322 322  
... ... @@ -414,7 +414,7 @@
414 414  
415 415  {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]]
416 416  
417 -== {{id name="HOMRONHOSTLINK"/}}**OMRON HOSTLINK** ==
445 +== C200HE Series Serial ==
418 418  
419 419  Supported series: Omron C200HE series
420 420  
1725933542710-763.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +616.8 KB
Content
1725933558402-579.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +616.8 KB
Content
1725933585867-921.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +223.1 KB
Content
1725933619328-454.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
1725933697098-418.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +241.3 KB
Content
1725933727638-698.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +101.9 KB
Content
1725933782144-300.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +313.6 KB
Content
1725933826453-416.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +187.2 KB
Content
1725933926323-707.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +237.3 KB
Content
1725934131262-239.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +7.6 KB
Content
1725934163105-489.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +11.1 KB
Content
XWiki.XWikiComments[0]
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.VZ
Comment
... ... @@ -1,0 +1,2 @@
1 +I have a 3070ig-O-RS v1.7 HMI panel.
2 +The Ethernet communication does work good with an OMRON CP1L-EM30DT1-D CPU, with the OMRON CJ TCP FINS Ethernet protocol on the 9600 FINS TCP port.
Date
... ... @@ -1,0 +1,1 @@
1 +2024-08-26 18:10:06.197