From version 36.1
edited by Devin Chen
on 2023/09/12 15:05
on 2023/09/12 15:05
Change comment:
There is no comment for this version
To version 38.1
edited by Devin Chen
on 2023/09/12 17:39
on 2023/09/12 17:39
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,52 +13,10 @@ 13 13 |Device No.|0 14 14 |HMI No.|0 15 15 16 -(% id="cke_bm_1048S" style="display:none" %)** ** (%%)**Configure the communication protocol**16 +(% id="cke_bm_1048S" style="display:none" %)** ** 17 17 18 - {{idname="Iimage-20220830143348-1.png"/}}18 +**Address List** 19 19 20 -(% style="text-align:center" %) 21 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]] 22 - 23 -{{id name="Iimage-20220830143511-2.png"/}} 24 - 25 -(% style="text-align:center" %) 26 -[[image:2.3.2.png]] 27 - 28 -**PLC Setting:** 29 - 30 -①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 31 -Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 32 - 33 -(% style="text-align:center" %) 34 -[[image:1.3.1.png]] 35 - 36 -②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 37 - 38 -(% style="text-align:center" %) 39 -[[image:1.3.2.png]] 40 - 41 -③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 42 - 43 -[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 44 -Note: Please configure the IP parameters of PLC according to the field needs 45 - 46 -(% style="text-align:center" %) 47 -[[image:1.4.png]] 48 - 49 -④Two rotary coding switches should be set depanding on the program paremeter: 50 -a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 51 - 52 -(% style="text-align:center" %) 53 -[[image:WeCom Screenshot_20230828090604.png]] 54 - 55 - 56 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List** 57 - 58 -(% style="text-align:center" %) 59 -[[image:WeCom.png]] 60 - 61 - 62 62 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 63 63 |(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999| 64 64 |W|W|W d|0~~99999| ... ... @@ -108,6 +108,52 @@ 108 108 |IR|IR|IR d|0~~99999| 109 109 |DR|DR|DR d|0~~99999| 110 110 69 +**Configure the communication protocol** 70 + 71 +{{id name="Iimage-20220830143348-1.png"/}} 72 + 73 +(% style="text-align:center" %) 74 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]] 75 + 76 +{{id name="Iimage-20220830143511-2.png"/}} 77 + 78 +(% style="text-align:center" %) 79 +[[image:2.3.2.png]] 80 + 81 +**PLC Setting:** 82 + 83 +①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 84 +Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 85 + 86 +(% style="text-align:center" %) 87 +[[image:1.3.1.png]] 88 + 89 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 90 + 91 +(% style="text-align:center" %) 92 +[[image:1.3.2.png]] 93 + 94 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 95 + 96 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 97 +Note: Please configure the IP parameters of PLC according to the field needs 98 + 99 +(% style="text-align:center" %) 100 +[[image:1.4.png]] 101 + 102 +④Two rotary coding switches should be set depanding on the program paremeter: 103 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 104 + 105 +(% style="text-align:center" %) 106 +[[image:WeCom Screenshot_20230828090604.png]] 107 + 108 + 109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.** 110 + 111 + 112 +(% style="text-align:center" %) 113 +[[image:WeCom.png]] 114 + 111 111 **Cable Wiring** 112 112 113 113 Pin Definition Diagram ... ... @@ -414,7 +414,7 @@ 414 414 415 415 {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]] 416 416 417 -== {{id name="HOMRONHOSTLINK"/}} **OMRONHOSTLINK**==421 +== {{id name="HOMRONHOSTLINK"/}}Omron C200H Serial == 418 418 419 419 Supported series: Omron C200HE series 420 420