... ... @@ -1,6 +1,6 @@
1 1  = {{id name="HOmron"/}}**Omron** =
2 2  
3 -== **CJ TCP FINS Ethemet** ==
3 +== **CJ2M Series Ethemet** ==
4 4  
5 5  Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21
6 6  
... ... @@ -13,52 +13,10 @@
13 13  |Device No.|0
14 14  |HMI No.|0
15 15  
16 -(% id="cke_bm_1048S" style="display:none" %)** **(%%)**Configure the communication protocol**
16 +(% id="cke_bm_1048S" style="display:none" %)** **
17 17  
18 -{{id name="Iimage-20220830143348-1.png"/}}
18 +**Address List**
19 19  
20 -(% style="text-align:center" %)
21 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]]
22 -
23 -{{id name="Iimage-20220830143511-2.png"/}}
24 -
25 -(% style="text-align:center" %)
26 -[[image:2.3.2.png]]
27 -
28 -**PLC Setting:**
29 -
30 -①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
31 -Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
32 -
33 -(% style="text-align:center" %)
34 -[[image:1.3.1.png]]
35 -
36 -②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
37 -
38 -(% style="text-align:center" %)
39 -[[image:1.3.2.png]]
40 -
41 -③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
42 -
43 -[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
44 -Note: Please configure the IP parameters of PLC according to the field needs
45 -
46 -(% style="text-align:center" %)
47 -[[image:1.4.png]]
48 -
49 -④Two rotary coding switches should be set depanding on the program paremeter:
50 -a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
51 -
52 -(% style="text-align:center" %)
53 -[[image:WeCom Screenshot_20230828090604.png]]
54 -
55 -
56 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
57 -
58 -(% style="text-align:center" %)
59 -[[image:WeCom.png]]
60 -
61 -
62 62  |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
63 63  |(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999|
64 64  |W|W|W d|0~~99999|
... ... @@ -108,6 +108,52 @@
108 108  |IR|IR|IR d|0~~99999|
109 109  |DR|DR|DR d|0~~99999|
110 110  
69 +**Configure the communication protocol**
70 +
71 +{{id name="Iimage-20220830143348-1.png"/}}
72 +
73 +(% style="text-align:center" %)
74 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]]
75 +
76 +{{id name="Iimage-20220830143511-2.png"/}}
77 +
78 +(% style="text-align:center" %)
79 +[[image:2.3.2.png]]
80 +
81 +**PLC Setting:**
82 +
83 +①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
84 +Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
85 +
86 +(% style="text-align:center" %)
87 +[[image:1.3.1.png]]
88 +
89 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90 +
91 +(% style="text-align:center" %)
92 +[[image:1.3.2.png]]
93 +
94 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
95 +
96 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
97 +Note: Please configure the IP parameters of PLC according to the field needs
98 +
99 +(% style="text-align:center" %)
100 +[[image:1.4.png]]
101 +
102 +④Two rotary coding switches should be set depanding on the program paremeter:
103 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
104 +
105 +(% style="text-align:center" %)
106 +[[image:WeCom Screenshot_20230828090604.png]]
107 +
108 +
109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.**
110 +
111 +
112 +(% style="text-align:center" %)
113 +[[image:WeCom.png]]
114 +
111 111  **Cable Wiring**
112 112  
113 113  Pin Definition Diagram
... ... @@ -316,7 +316,7 @@
316 316  
317 317  {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
318 318  
319 -== {{id name="HCV2FCJ1M2FCS1H"/}}**CV/CJ1M/CS1H** ==
323 +== {{id name="HCV2FCJ1M2FCS1H"/}}**CJ2M Series Serial ** ==
320 320  
321 321  **HMI Setting:**
322 322  
... ... @@ -414,7 +414,7 @@
414 414  
415 415  {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]]
416 416  