... ... @@ -13,10 +13,52 @@
13 13  |Device No.|0
14 14  |HMI No.|0
15 15  
16 -(% id="cke_bm_1048S" style="display:none" %)** **
16 +(% id="cke_bm_1048S" style="display:none" %)** **(%%)**Configure the communication protocol**
17 17  
18 -**Address List**
18 +{{id name="Iimage-20220830143348-1.png"/}}
19 19  
20 +(% style="text-align:center" %)
21 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]]
22 +
23 +{{id name="Iimage-20220830143511-2.png"/}}
24 +
25 +(% style="text-align:center" %)
26 +[[image:2.3.2.png]]
27 +
28 +**PLC Setting:**
29 +
30 +①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
31 +Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
32 +
33 +(% style="text-align:center" %)
34 +[[image:1.3.1.png]]
35 +
36 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
37 +
38 +(% style="text-align:center" %)
39 +[[image:1.3.2.png]]
40 +
41 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
42 +
43 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
44 +Note: Please configure the IP parameters of PLC according to the field needs
45 +
46 +(% style="text-align:center" %)
47 +[[image:1.4.png]]
48 +
49 +④Two rotary coding switches should be set depanding on the program paremeter:
50 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
51 +
52 +(% style="text-align:center" %)
53 +[[image:WeCom Screenshot_20230828090604.png]]
54 +
55 +
56 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
57 +
58 +(% style="text-align:center" %)
59 +[[image:WeCom.png]]
60 +
61 +
20 20  |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
21 21  |(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999|
22 22  |W|W|W d|0~~99999|
... ... @@ -66,52 +66,6 @@
66 66  |IR|IR|IR d|0~~99999|
67 67  |DR|DR|DR d|0~~99999|
68 68  
69 -**Configure the communication protocol**
70 -
71 -{{id name="Iimage-20220830143348-1.png"/}}
72 -
73 -(% style="text-align:center" %)
74 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]]
75 -
76 -{{id name="Iimage-20220830143511-2.png"/}}
77 -
78 -(% style="text-align:center" %)
79 -[[image:2.3.2.png]]
80 -
81 -**PLC Setting:**
82 -
83 -①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
84 -Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
85 -
86 -(% style="text-align:center" %)
87 -[[image:1.3.1.png]]
88 -
89 -②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90 -
91 -(% style="text-align:center" %)
92 -[[image:1.3.2.png]]
93 -
94 -③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
95 -
96 -[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
97 -Note: Please configure the IP parameters of PLC according to the field needs
98 -
99 -(% style="text-align:center" %)
100 -[[image:1.4.png]]
101 -
102 -④Two rotary coding switches should be set depanding on the program paremeter:
103 -a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
104 -
105 -(% style="text-align:center" %)
106 -[[image:WeCom Screenshot_20230828090604.png]]
107 -
108 -
109 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.**
110 -
111 -
112 -(% style="text-align:center" %)
113 -[[image:WeCom.png]]
114 -
115 115  **Cable Wiring**
116 116  
117 117  Pin Definition Diagram
... ... @@ -418,7 +418,7 @@
418 418  
419 419  {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]]
420 420  
421 -== {{id name="HOMRONHOSTLINK"/}}Omron C200H Serial ==
417 +== {{id name="HOMRONHOSTLINK"/}}**OMRON HOSTLINK** ==
422 422  