From version 41.1
edited by Devin Chen
on 2023/09/12 17:53
on 2023/09/12 17:53
Change comment:
There is no comment for this version
To version 36.1
edited by Devin Chen
on 2023/09/12 15:05
on 2023/09/12 15:05
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,6 @@ 1 1 = {{id name="HOmron"/}}**Omron** = 2 2 3 -== **CJ 2MSeriesEthemet** ==3 +== **CJ TCP FINS Ethemet** == 4 4 5 5 Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21 6 6 ... ... @@ -13,10 +13,52 @@ 13 13 |Device No.|0 14 14 |HMI No.|0 15 15 16 -(% id="cke_bm_1048S" style="display:none" %)** ** 16 +(% id="cke_bm_1048S" style="display:none" %)** **(%%)**Configure the communication protocol** 17 17 18 - **AddressList**18 +{{id name="Iimage-20220830143348-1.png"/}} 19 19 20 +(% style="text-align:center" %) 21 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]] 22 + 23 +{{id name="Iimage-20220830143511-2.png"/}} 24 + 25 +(% style="text-align:center" %) 26 +[[image:2.3.2.png]] 27 + 28 +**PLC Setting:** 29 + 30 +①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 31 +Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 32 + 33 +(% style="text-align:center" %) 34 +[[image:1.3.1.png]] 35 + 36 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 37 + 38 +(% style="text-align:center" %) 39 +[[image:1.3.2.png]] 40 + 41 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 42 + 43 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 44 +Note: Please configure the IP parameters of PLC according to the field needs 45 + 46 +(% style="text-align:center" %) 47 +[[image:1.4.png]] 48 + 49 +④Two rotary coding switches should be set depanding on the program paremeter: 50 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 51 + 52 +(% style="text-align:center" %) 53 +[[image:WeCom Screenshot_20230828090604.png]] 54 + 55 + 56 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List** 57 + 58 +(% style="text-align:center" %) 59 +[[image:WeCom.png]] 60 + 61 + 20 20 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 21 21 |(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999| 22 22 |W|W|W d|0~~99999| ... ... @@ -66,52 +66,6 @@ 66 66 |IR|IR|IR d|0~~99999| 67 67 |DR|DR|DR d|0~~99999| 68 68 69 -**Configure the communication protocol** 70 - 71 -{{id name="Iimage-20220830143348-1.png"/}} 72 - 73 -(% style="text-align:center" %) 74 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]] 75 - 76 -{{id name="Iimage-20220830143511-2.png"/}} 77 - 78 -(% style="text-align:center" %) 79 -[[image:2.3.2.png]] 80 - 81 -**PLC Setting:** 82 - 83 -①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 84 -Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 85 - 86 -(% style="text-align:center" %) 87 -[[image:1.3.1.png]] 88 - 89 -②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 90 - 91 -(% style="text-align:center" %) 92 -[[image:1.3.2.png]] 93 - 94 -③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 95 - 96 -[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 97 -Note: Please configure the IP parameters of PLC according to the field needs 98 - 99 -(% style="text-align:center" %) 100 -[[image:1.4.png]] 101 - 102 -④Two rotary coding switches should be set depanding on the program paremeter: 103 -a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 104 - 105 -(% style="text-align:center" %) 106 -[[image:WeCom Screenshot_20230828090604.png]] 107 - 108 - 109 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.** 110 - 111 - 112 -(% style="text-align:center" %) 113 -[[image:WeCom.png]] 114 - 115 115 **Cable Wiring** 116 116 117 117 Pin Definition Diagram ... ... @@ -121,7 +121,7 @@ 121 121 (% style="text-align:center" %) 122 122 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 123 123 124 -== {{id name="HCS128CP1E2FCP1H29"/}}**CP1E Series Serial** ==120 +== {{id name="HCS128CP1E2FCP1H29"/}}**CS1(CP1E/CP1H)** == 125 125 126 126 Supported device: OMRON CS1(CP1E/CP1H) 127 127 ... ... @@ -320,7 +320,7 @@ 320 320 321 321 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 322 322 323 -== {{id name="HCV2FCJ1M2FCS1H"/}}**CJ 2Meries Serial** ==319 +== {{id name="HCV2FCJ1M2FCS1H"/}}**CV/CJ1M/CS1H** == 324 324 325 325 **HMI Setting:** 326 326 ... ... @@ -418,7 +418,7 @@ 418 418 419 419 {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]] 420 420 421 -== {{id name="HOMRONHOSTLINK"/}}O mronC200Herial==417 +== {{id name="HOMRONHOSTLINK"/}}**OMRON HOSTLINK** == 422 422 423 423 Supported series: Omron C200HE series 424 424