@@ -282,40 +282,44 @@ |
282 |
282 |
|
283 |
283 |
2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed. |
284 |
284 |
|
285 |
|
-{{id name="I12.PLCProtocol_html_4156caf6f116c570.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1275dbbb73675c45.png||alt="12.PLC Protocol_html_4156caf6f116c570.png" height="277" width="600"]] |
|
285 |
+(% style="text-align:center" %) |
|
286 |
+[[image:1725933697098-418.png]] |
286 |
286 |
|
287 |
287 |
**Export labels from Sysmac Studio** |
288 |
288 |
|
289 |
289 |
Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables]; |
290 |
290 |
|
291 |
|
-{{id name="I12.PLCProtocol_html_26f91dee66c723e9.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4d41889d12980317.png||alt="12.PLC Protocol_html_26f91dee66c723e9.png" height="276" width="600"]] |
|
292 |
+(% style="text-align:center" %) |
|
293 |
+[[image:1725933727638-698.png]] |
292 |
292 |
|
293 |
|
-Launch PIStudio, in [Communication] Settings add Omron NX Ethernet/IP protocol; |
|
295 |
+[[image:1725933619328-454.png]] |
294 |
294 |
|
295 |
|
-Click [Label manage]; |
|
297 |
+Create a .CSV file,and Paste the [CX-Designer] into it. |
296 |
296 |
|
297 |
|
-{{id name="I12.PLCProtocol_html_cd38d2d0c5187f6b.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c02902d35021dbd.png||alt="12.PLC Protocol_html_cd38d2d0c5187f6b.png" height="276" width="600"]] |
|
299 |
+(% style="text-align:center" %) |
|
300 |
+[[image:1725933782144-300.png]] |
298 |
298 |
|
299 |
|
-Click [Import labels] and then select the file exported in step 1; |
|
302 |
+Launch PIStudio, in [Communication] Settings add [Omron Ethernet/IP (NX/NJ Serirs)] protocol; |
300 |
300 |
|
301 |
|
-{{id name="I12.PLCProtocol_html_52bd5da678bef9b4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_31ee4b3995e48a09.png||alt="12.PLC Protocol_html_52bd5da678bef9b4.png" height="403" width="600"]] |
|
304 |
+[[image:1725933826453-416.png]] |
302 |
302 |
|
303 |
|
-The Import Status field shows the result, click [OK] to finish importing address labels; |
|
306 |
+Click [Label manage];Click [Import Tags form file] and then Choose the .CSV file you need; |
304 |
304 |
|
305 |
|
-{{id name="I12.PLCProtocol_html_7f0465a589b98912.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_2e9eb22f4eb0faef.png||alt="12.PLC Protocol_html_7f0465a589b98912.png" height="291" width="600"]] |
|
308 |
+(% style="text-align:center" %) |
|
309 |
+[[image:1725933926323-707.png]] |
306 |
306 |
|
|
311 |
+ |
307 |
307 |
**Communication Settings** |
308 |
308 |
|
309 |
|
-Enable HMI Ethernet in [Project Settings]; |
310 |
|
- |
311 |
|
-{{id name="I12.PLCProtocol_html_43b671f18153910d.png-4"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]] |
312 |
|
- |
313 |
313 |
Set PLC IP in [Device IP] settings; |
314 |
314 |
|
315 |
|
-{{id name="I12.PLCProtocol_html_437cb087b36b5784.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_3b29b2c9873ab9cc.png||alt="12.PLC Protocol_html_437cb087b36b5784.png" height="330" width="600"]] |
|
316 |
+(% style="text-align:center" %) |
|
317 |
+[[image:1725934163105-489.png||height="99" width="241"]] |
316 |
316 |
|
317 |
|
-{{id name="I12.PLCProtocol_html_60ef71528a99abf5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c45114a482fa38f6.png||alt="12.PLC Protocol_html_60ef71528a99abf5.png" height="188" width="554"]] |
318 |
318 |
|
|
320 |
+(% style="text-align:center" %) |
|
321 |
+[[image:1725934131262-239.png]] |
|
322 |
+ |
319 |
319 |
**Cable Wiring** |
320 |
320 |
|
321 |
321 |
{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] |