Changes for page Omron

Last modified by Jett on 2024/10/23 20:42

From version 44.1
edited by Jett
on 2024/06/18 15:54
Change comment: There is no comment for this version
To version 46.1
edited by Jett
on 2024/09/10 10:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -264,7 +264,7 @@
264 264  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
265 265  * {{id name="I12.PLCProtocol_html_d428cad280fdefb3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f434f58797d3c0da.png||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]] Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
266 266  
267 -== {{id name="HNXEtherNet2FIP"/}}**NX EtherNet/IP** ==
267 +== {{id name="HNXEtherNet2FIP"/}}**Ethernet/IP (NX/NJ Serirs)** ==
268 268  
269 269  Supported series: Omron NX/NJ series
270 270  
... ... @@ -276,6 +276,26 @@
276 276  |Port No.|44818|
277 277  |PLC station No.|1|
278 278  
279 +**Address list**
280 +
281 +|Data type|Data format in PIStudio|Memo
282 +|BOOL|bit|
283 +|Byte|16-bit BCD,HEX,Binary,Unsigned|8-bit
284 +|SInt|16-bit BCD,HEX,Binary,Signed|8-bit
285 +|USInt|16-bit BCD,HEX,Binary,Unsigned|8-bit
286 +|Word|16-bit BCD,HEX,Binary,Unsigned|16-bit
287 +|Int|16-bit BCD,HEX,Binary,Signed|16-bit
288 +|UInt|16-bit BCD,HEX,Binary,Unsigned|16-bit
289 +|DWord|32-bit BCD, Hex, Binary, Unsigned|32-bit
290 +|DInt|32-bit BCD, Hex, Binary, Signed|32-bit
291 +|Real|32-bit Float|32-bit
292 +|UDInt|32-bit BCD, Hex, Binary, Unsigned|32-bit
293 +|LInt|64-bit Signed|64-bit
294 +|ULInt|64-bit USigned|64-bit
295 +|LWord|64-bit USigned|64-bit
296 +|LRea|64-bit Float|64-bit
297 +|Array|All of the above types|
298 +
279 279  **Instruction**
280 280  
281 281  1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
... ... @@ -282,40 +282,44 @@
282 282  
283 283  2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed.
284 284  
285 -{{id name="I12.PLCProtocol_html_4156caf6f116c570.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1275dbbb73675c45.png||alt="12.PLC Protocol_html_4156caf6f116c570.png" height="277" width="600"]]
305 +(% style="text-align:center" %)
306 +[[image:1725933697098-418.png]]
286 286  
287 287  **Export labels from Sysmac Studio**
288 288  
289 289  Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables];
290 290  
291 -{{id name="I12.PLCProtocol_html_26f91dee66c723e9.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4d41889d12980317.png||alt="12.PLC Protocol_html_26f91dee66c723e9.png" height="276" width="600"]]
312 +(% style="text-align:center" %)
313 +[[image:1725933727638-698.png]]
292 292  
293 -Launch PIStudio, in [Communication] Settings add Omron NX Ethernet/IP protocol;
315 +[[image:1725933619328-454.png]]
294 294  
295 -Click [Label manage];
317 +Create a .CSV file,and Paste the [CX-Designer] into it.
296 296  
297 -{{id name="I12.PLCProtocol_html_cd38d2d0c5187f6b.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c02902d35021dbd.png||alt="12.PLC Protocol_html_cd38d2d0c5187f6b.png" height="276" width="600"]]
319 +(% style="text-align:center" %)
320 +[[image:1725933782144-300.png]]
298 298  
299 -Click [Import labels] and then select the file exported in step 1;
322 +Launch PIStudio, in [Communication] Settings add [Omron Ethernet/IP (NX/NJ Serirs)] protocol;
300 300  
301 -{{id name="I12.PLCProtocol_html_52bd5da678bef9b4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_31ee4b3995e48a09.png||alt="12.PLC Protocol_html_52bd5da678bef9b4.png" height="403" width="600"]]
324 +[[image:1725933826453-416.png]]
302 302  
303 -The Import Status field shows the result, click [OK] to finish importing address labels;
326 +Click [Label manage];Click [Import Tags form file] and then Choose the .CSV file you need;
304 304  
305 -{{id name="I12.PLCProtocol_html_7f0465a589b98912.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_2e9eb22f4eb0faef.png||alt="12.PLC Protocol_html_7f0465a589b98912.png" height="291" width="600"]]
328 +(% style="text-align:center" %)
329 +[[image:1725933926323-707.png]]
306 306  
331 +
307 307  **Communication Settings**
308 308  
309 -Enable HMI Ethernet in [Project Settings];
310 -
311 -{{id name="I12.PLCProtocol_html_43b671f18153910d.png-4"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
312 -
313 313  Set PLC IP in [Device IP] settings;
314 314  
315 -{{id name="I12.PLCProtocol_html_437cb087b36b5784.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_3b29b2c9873ab9cc.png||alt="12.PLC Protocol_html_437cb087b36b5784.png" height="330" width="600"]]
336 +(% style="text-align:center" %)
337 +[[image:1725934163105-489.png||height="99" width="241"]]
316 316  
317 -{{id name="I12.PLCProtocol_html_60ef71528a99abf5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c45114a482fa38f6.png||alt="12.PLC Protocol_html_60ef71528a99abf5.png" height="188" width="554"]]
318 318  
340 +(% style="text-align:center" %)
341 +[[image:1725934131262-239.png]]
342 +
319 319  **Cable Wiring**
320 320  
321 321  {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1725933542710-763.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +616.8 KB
Content
1725933558402-579.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +616.8 KB
Content
1725933585867-921.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +223.1 KB
Content
1725933619328-454.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
1725933697098-418.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +241.3 KB
Content
1725933727638-698.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +101.9 KB
Content
1725933782144-300.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +313.6 KB
Content
1725933826453-416.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +187.2 KB
Content
1725933926323-707.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +237.3 KB
Content
1725934131262-239.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +7.6 KB
Content
1725934163105-489.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +11.1 KB
Content
XWiki.XWikiComments[0]
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.VZ
Comment
... ... @@ -1,0 +1,2 @@
1 +I have a 3070ig-O-RS v1.7 HMI panel.
2 +The Ethernet communication does work good with an OMRON CP1L-EM30DT1-D CPU, with the OMRON CJ TCP FINS Ethernet protocol on the 9600 FINS TCP port.
Date
... ... @@ -1,0 +1,1 @@
1 +2024-08-26 18:10:06.197