Changes for page Omron

Last modified by Jett on 2024/10/23 20:42

From version 54.1
edited by Jett
on 2024/10/23 20:42
Change comment: There is no comment for this version
To version 46.1
edited by Jett
on 2024/09/10 10:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -271,7 +271,7 @@
271 271  **HMI Setting**
272 272  
273 273  |**Items**|**Settings**|**Note**
274 -|Protocol|Omron NX/NJ Ethernet/IP|
274 +|Protocol|Omron NX Ethernet/IP|
275 275  |Connection|Ethernet|
276 276  |Port No.|44818|
277 277  |PLC station No.|1|
... ... @@ -278,32 +278,24 @@
278 278  
279 279  **Address list**
280 280  
281 -|=Data type|=Memo|=**Range**
282 -|BOOL|1|FALSE(0) or TRUE(1)
283 -|BYTE|8|0~~255
284 -|WORD|16|0~~65535
285 -|DWORD|32|0~~4294967295
286 -|LWORD|64|0~~(2^64-1)
287 -|SINT|8|-128~~127
288 -|USINT|8|0~~255
289 -|INT|16|-32768~~32767
290 -|UINT|16|0~~65535
291 -|DINT|32|-2147483648~~2147483647
292 -|UDINT|32|0~~4294967295
293 -|LINT|64|(-2^63)~~(2^63-1)
294 -|ULINT|64|0~~(2^64-1)
295 -|REAL|32|-3.402823466E+38~~3.402823466E+38
296 -|LREAL|64|(((
297 --1.7976931348623158E+308~~1.79769313
281 +|Data type|Data format in PIStudio|Memo
282 +|BOOL|bit|
283 +|Byte|16-bit BCD,HEX,Binary,Unsigned|8-bit
284 +|SInt|16-bit BCD,HEX,Binary,Signed|8-bit
285 +|USInt|16-bit BCD,HEX,Binary,Unsigned|8-bit
286 +|Word|16-bit BCD,HEX,Binary,Unsigned|16-bit
287 +|Int|16-bit BCD,HEX,Binary,Signed|16-bit
288 +|UInt|16-bit BCD,HEX,Binary,Unsigned|16-bit
289 +|DWord|32-bit BCD, Hex, Binary, Unsigned|32-bit
290 +|DInt|32-bit BCD, Hex, Binary, Signed|32-bit
291 +|Real|32-bit Float|32-bit
292 +|UDInt|32-bit BCD, Hex, Binary, Unsigned|32-bit
293 +|LInt|64-bit Signed|64-bit
294 +|ULInt|64-bit USigned|64-bit
295 +|LWord|64-bit USigned|64-bit
296 +|LRea|64-bit Float|64-bit
297 +|Array|All of the above types|
298 298  
299 -48623158E+308
300 -)))
301 -|DATE|32|1970-01-01~~2106-02-07
302 -|TIME|32|0D0H0M0S0MS~~49D17H2M47S295MS
303 -|DATE_AND_TIME|32|1970-1-1-0:0:0~~2106-02-07-06:28:15
304 -|TIME_OF_DAY|32|0:0:0~~23:59:59.999
305 -|STRING| |
306 -
307 307  **Instruction**
308 308  
309 309  1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
... ... @@ -320,16 +320,10 @@
320 320  (% style="text-align:center" %)
321 321  [[image:1725933727638-698.png]]
322 322  
323 -(% style="text-align:center" %)
324 324  [[image:1725933619328-454.png]]
325 325  
326 326  Create a .CSV file,and Paste the [CX-Designer] into it.
327 327  
328 -(% class="box infomessage" %)
329 -(((
330 -**✎Note**: Make sure the CSV data is separated by commas.
331 -)))
332 -
333 333  (% style="text-align:center" %)
334 334  [[image:1725933782144-300.png]]
335 335