Wiki source code of Omron

Version 15.1 by Hunter on 2023/08/24 18:11

Show last authors
1 = {{id name="HOmron"/}}**Omron** =
2
3 == {{id name="HCJTCPFINSEthemet"/}}**CJ TCP FINS Ethemet** ==
4
5 Supported device:CJ series, CJ1W-EIP21
6
7 **HMI Settings**
8
9 |=**Items**|=**Settings**|=**Note**
10 |Protocol|OMRON CJ TCP FINS Ethemet|
11 |Connection|Ethernet|
12 |Port No.|9600|
13 |Device No.|0|
14 |HMI No.|0|
15
16 **Address List**
17
18 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
19 |Bit|CIO|CIO|CIO d|0~~99999|
20 |Bit|W|W|W d|0~~99999|
21 |Bit|D|D|D d|0~~99999|
22 |Bit|H|H|H d|0~~99999|
23 |Bit|A|A|A d|0~~99999|
24 |Bit|T|T|T h|0~~99999|
25 |Bit|CF|CF|CF d|0~~99999|
26 |Bit|FF|FF|FF d|0~~99999|
27 |Bit|C|C|C d|0~~99999|
28 |Bit|EM0|EM0|EM0 d|0~~99999|
29 |Bit|EM1|EM1|EM1 d|0~~99999|
30 |Bit|EM2|EM2|EM2 d|0~~99999|
31 |Bit|EM3|EM3|EM3 d|0~~99999|
32 |Bit|EM4|EM4|EM4 d|0~~99999|
33 |Bit|EM5|EM5|EM5 h|0~~99999|
34 |Bit|EM6|EM6|EM6 d|0~~99999|
35 |Bit|EM7|EM7|EM7 d|0~~99999|
36 |Bit|EM8|EM8|EM8 d|0~~99999|
37 |Bit|EM9|EM9|EM9 d|0~~99999|
38 |Bit|EMA|EMA|EMA d|0~~99999|
39 |Bit|EMB|EMB|EMB d|0~~99999|
40 |Bit|EMC|EMC|EMC d|0~~99999|
41 |Bit|Lamp|Lamp|Lamp d|0~~0|
42 |Word|CIO|CIO|CIO d|0~~99999|
43 |Word|W|W|W d|0~~99999|
44 |Word|D|D|D d|0~~99999|
45 |Word|H|H|H d|0~~99999|
46 |Word|A|A|A d|0~~99999|
47 |Word|T|T|T h|0~~99999|
48 |Word|CF|CF|CF d|0~~99999|
49 |Word|FF|FF|FF d|0~~99999|
50 |Word|C|C|C d|0~~99999|
51 |Word|EM0|EM0|EM0 d|0~~99999|
52 |Word|EM1|EM1|EM1 d|0~~99999|
53 |Word|EM2|EM2|EM2 d|0~~99999|
54 |Word|EM3|EM3|EM3 d|0~~99999|
55 |Word|EM4|EM4|EM4 d|0~~99999|
56 |Word|EM5|EM5|EM5 h|0~~99999|
57 |Word|EM6|EM6|EM6 d|0~~99999|
58 |Word|EM7|EM7|EM7 d|0~~99999|
59 |Word|EM8|EM8|EM8 d|0~~99999|
60 |Word|EM9|EM9|EM9 d|0~~99999|
61 |Word|EMA|EMA|EMA d|0~~99999|
62 |Word|EMB|EMB|EMB d|0~~99999|
63 |Word|EMC|EMC|EMC d|0~~99999|
64 |Word|IR|IR|IR d|0~~99999|
65 |Word|DR|DR|DR d|0~~99999|
66
67 **Configure the communication protocol**
68
69 {{id name="Iimage-20220830143348-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]]
70
71 {{id name="Iimage-20220830143511-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d00a6eb441a5efea.png||alt="image-20220830143511-2.png" height="905" width="1038"]]
72
73 **Configure CJ1W-EIP21 connect with HMI**
74
75 {{id name="IftEVGvAprh.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_111d091c99a042ec.png||alt="ftEVGvAprh.png" height="574" width="540"]]
76
77 Select TCP_Client_2N
78
79 {{id name="IRURXWcgyCd.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_42d153488e9793ba.png||alt="RURXWcgyCd.png" height="706" width="909"]]
80
81 **Cable Wiring**
82
83 Pin Definition Diagram
84
85 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-3"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
86
87 == {{id name="HCS128CP1E2FCP1H29"/}}**CS1(CP1E/CP1H)** ==
88
89 Supported device: OMRON CS1(CP1E/CP1H)
90
91 **HMI Settings**
92
93 |=**Items**|=**Settings**|=**Note**
94 |Protocol|OMRON CS1(CP1E/CP1H)|
95 |Connection|RS232 (9600, 2, 7, EVEN)|
96 |Port No.|None|
97 |PLC station No.|0|
98
99 **Address List**
100
101 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
102 |Bit|CIO|CIO|CIO d|0~~99999|
103 |Bit|W|W|W d|0~~99999|
104 |Bit|D|D|D d|0~~99999|
105 |Bit|H|H|H d|0~~99999|
106 |Bit|A|A|A d|0~~99999|
107 |Bit|TF|T|T h|0~~99999|
108 |Bit|CF|CF|CF d|0~~99999|
109 |Bit|T|FF|FF d|0~~99999|
110 |Bit|C|C|C d|0~~99999|
111 |Bit|EM0|EM0|EM0 d|0~~99999|
112 |Bit|EM1|EM1|EM1 d|0~~99999|
113 |Bit|EM2|EM2|EM2 d|0~~99999|
114 |Bit|EM3|EM3|EM3 d|0~~99999|
115 |Bit|EM4|EM4|EM4 d|0~~99999|
116 |Bit|EM5|EM5|EM5 h|0~~99999|
117 |Bit|EM6|EM6|EM6 d|0~~99999|
118 |Bit|EM7|EM7|EM7 d|0~~99999|
119 |Bit|EM8|EM8|EM8 d|0~~99999|
120 |Bit|EM9|EM9|EM9 d|0~~99999|
121 |Bit|EMA|EMA|EMA d|0~~99999|
122 |Bit|EMB|EMB|EMB d|0~~99999|
123 |Bit|EMC|EMC|EMC d|0~~99999|
124 |Word|CIO|CIO|CIO d|0~~99999|
125 |Word|W|W|W d|0~~99999|
126 |Word|D|D|D d|0~~99999|
127 |Word|H|H|H d|0~~99999|
128 |Word|A|A|A d|0~~99999|
129 |Word|T|T|T h|0~~99999|
130 |Word|CIO|CF|CF d|0~~99999|
131 |Word|C|C|C d|0~~99999|
132 |Word|EM0|EM0|EM0 d|0~~99999|
133 |Word|EM1|EM1|EM1 d|0~~99999|
134 |Word|EM2|EM2|EM2 d|0~~99999|
135 |Word|EM3|EM3|EM3 d|0~~99999|
136 |Word|EM4|EM4|EM4 d|0~~99999|
137 |Word|EM5|EM5|EM5 h|0~~99999|
138 |Word|EM6|EM6|EM6 d|0~~99999|
139 |Word|EM7|EM7|EM7 d|0~~99999|
140 |Word|EM8|EM8|EM8 d|0~~99999|
141 |Word|EM9|EM9|EM9 d|0~~99999|
142 |Word|EMA|EMA|EMA d|0~~99999|
143 |Word|EMB|EMB|EMB d|0~~99999|
144 |Word|EMC|EMC|EMC d|0~~99999|
145 |Word|IR|IR|IR d|0~~99999|
146 |Word|DR|DR|DR d|0~~99999|
147
148 **Configure the communication protocol**
149
150 {{id name="Iimage-20220902153118-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4acef6476c6f9de3.png||alt="image-20220902153118-1.png" height="735" width="616"]]
151
152 {{id name="Iimage-20220902151322-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4f9620139b8a44b3.png||alt="image-20220902151322-2.png" height="905" width="1038"]]
153
154 {{id name="cke_bm_27437S"/}}** PLC Settings(CX-Programmer)**
155
156 Open cx-programmer, create a new PLC project or open the project that has been created.
157 Create new project: [File]→[New]→[Device Type]CP1E→[settings]→[General]→[CPU Type]N30→[OK]→[OK].
158
159 {{id name="I1.25DE57A0B65B05EFAD.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_aa70463d933c7549.png||alt="1.2 工程新建D.png" height="660" width="1134"]]
160
161 PLC Default Parameters:[Settings]→[Built-in RS232C Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link(Defaut).
162
163 {{id name="I1.34E3253E353C26570768467E5770B-914D7F6ED.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_84484fbbb00ca61.png||alt="1.3 串口参数的查看-配置D.png" height="660" width="1134"]]
164
165 **Cable Wiring**
166
167 {{id name="I56FE72473.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4c5480a409965d39.png||alt="image-20220902153949-2.png" height="508" width="2014"]]
168
169 Pin Definition Diagram
170
171 {{id name="I3.1.263A553E3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ad6138e6812c2253.png||alt="image-20220902154056-3.png" height="235" width="332"]]
172
173 == {{id name="HEC55Protocol"/}}**EC55 Protocol** ==
174
175 Supported device: EC55 temperature instrument
176
177 **1)HMI Settings**
178
179 |**Items**|**Settings**|**Note**
180 |Protocol|Omron EC55|
181 |Connection|RS485 (9600, 2, 7, EVEN)|
182 |Port No.|None|
183 |PLC station No.|0|
184
185 **2)Address List**
186
187 |**Type**|**Register**|**Device range**|**HMI range**|**Function**
188 |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
189 |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
190 |C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
191 |(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
192 |81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
193 |83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
194 |CP|-|0-6|Read controller intrinsic property
195 |CS|-|0-2|Read controller states
196 |CA|-|0-17|Action command
197
198 **3)Device Settings**
199
200 Omron E5CC PLC configuration
201
202 After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
203
204 {{id name="I12.PLCProtocol_html_3d95e093792ba98a.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ca4d99a0d2ffe097.png||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
205
206 According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
207
208 {{id name="I12.PLCProtocol_html_be583aa69dd6cf4c.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_984474debc119fab.png||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
209
210 **✎Note:** The communication settings for HMI should be consistent with this setting.
211
212 **Cable Wiring**
213
214 {{id name="I12.PLCProtocol_html_5e9a81a14106da9e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7b2556c42d43a768.png||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
215
216 {{id name="I12.PLCProtocol_html_1897d92be6948d58.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6d16b5adff76549.png||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
217
218 **✎Note:**
219
220 * COM3 only available in PI8000/PI9000 series.
221 * CA address could not support continuous writing function;
222 * Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
223 * When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
224 * When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
225 * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
226 * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
227 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
228 * {{id name="I12.PLCProtocol_html_d428cad280fdefb3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f434f58797d3c0da.png||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]] Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
229
230 == {{id name="HNXEtherNet2FIP"/}}**NX EtherNet/IP** ==
231
232 Supported series: Omron NX/NJ series
233
234 **HMI Setting**
235
236 |**Items**|**Settings**|**Note**
237 |Protocol|Omron NX Ethernet/IP|
238 |Connection|Ethernet|
239 |Port No.|44818|
240 |PLC station No.|1|
241
242 **Instruction**
243
244 1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
245
246 2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed.
247
248 {{id name="I12.PLCProtocol_html_4156caf6f116c570.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1275dbbb73675c45.png||alt="12.PLC Protocol_html_4156caf6f116c570.png" height="277" width="600"]]
249
250 **Export labels from Sysmac Studio**
251
252 Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables];
253
254 {{id name="I12.PLCProtocol_html_26f91dee66c723e9.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4d41889d12980317.png||alt="12.PLC Protocol_html_26f91dee66c723e9.png" height="276" width="600"]]
255
256 Launch PIStudio, in [Communication] Settings add Omron NX Ethernet/IP protocol;
257
258 Click [Label manage];
259
260 {{id name="I12.PLCProtocol_html_cd38d2d0c5187f6b.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c02902d35021dbd.png||alt="12.PLC Protocol_html_cd38d2d0c5187f6b.png" height="276" width="600"]]
261
262 Click [Import labels] and then select the file exported in step 1;
263
264 {{id name="I12.PLCProtocol_html_52bd5da678bef9b4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_31ee4b3995e48a09.png||alt="12.PLC Protocol_html_52bd5da678bef9b4.png" height="403" width="600"]]
265
266 The Import Status field shows the result, click [OK] to finish importing address labels;
267
268 {{id name="I12.PLCProtocol_html_7f0465a589b98912.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_2e9eb22f4eb0faef.png||alt="12.PLC Protocol_html_7f0465a589b98912.png" height="291" width="600"]]
269
270 **Communication Settings**
271
272 Enable HMI Ethernet in [Project Settings];
273
274 {{id name="I12.PLCProtocol_html_43b671f18153910d.png-4"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="107" width="405"]]
275
276 Set PLC IP in [Device IP] settings;
277
278 {{id name="I12.PLCProtocol_html_437cb087b36b5784.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_3b29b2c9873ab9cc.png||alt="12.PLC Protocol_html_437cb087b36b5784.png" height="330" width="600"]]
279
280 {{id name="I12.PLCProtocol_html_60ef71528a99abf5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c45114a482fa38f6.png||alt="12.PLC Protocol_html_60ef71528a99abf5.png" height="188" width="554"]]
281
282 **Cable Wiring**
283
284 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
285
286 == {{id name="HCV2FCJ1M2FCS1H"/}}**CV/CJ1M/CS1H** ==
287
288 **HMI Setting:**
289
290 |=**Parameters**|=**Recommended**
291 |=**PLC type**|OMRON CV/CJ1M/CS1H
292 |=**PLC I/F**|RS232/RS485
293 |=**Baud rate**|9600
294 |=**Data bits**|7
295 |=**Parity**|Even
296 |=**Stop bits**|2
297 |=**PLC sta. no.**|0
298
299 **PLC Setting:**
300
301 Open cx-programmer, create a new PLC project or open the project that has been created.
302 Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
303
304 {{id name="I1.265B05EFA5DE57A0B.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png||alt="1.2 新建工程.png" height="660" width="1134"]]
305
306 PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link.
307 Note:The serial port parameters should be set depending on field requirements
308
309 {{id name="I1.34E3253E353C26570914D7F6E.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d4a08b7e4dfac0bd.png||alt="1.3串口参数配置.png" height="660" width="1134"]]
310
311 **Device Address:**
312
313 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
314 |=B|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay
315 |=B|W|DDDDDdd|0 ~~65535.15|Hold Relay
316 |=B|D|DDDDDdd|0 ~~65535.15|Link Relay
317 |=B|H|DDDDDdd|0 ~~65535.15|
318 |=B|A|DDDDDdd|0 ~~65535.15|
319 |=B|TF|DDDDD|0 ~~ 99999|
320 |=B|CF|DDDDD|0 ~~ 99999|Auxiliary Relay
321 |=B|T|DDDDDdd|0 ~~65535.15|
322 |=B|C|DDDDDdd|0 ~~65535.15|
323 |=B|EM0|DDDDDdd|0 ~~ 99999.15|
324 |=B|EM1|DDDDDdd|0 ~~ 99999.15|
325 |=B|EM2|DDDDDdd|0 ~~ 99999.15|
326 |=B|EM3|DDDDDdd|0 ~~ 99999.15|
327 |=B|EM4|DDDDDdd|0 ~~ 99999.15|
328 |=B|EM5|DDDDDdd|0 ~~ 99999.15|
329 |=B|EM6|DDDDDdd|0 ~~ 99999.15|
330 |=B|EM7|DDDDDdd|0 ~~ 99999.15|
331 |=B|EM8|DDDDDdd|0 ~~ 99999.15|
332 |=B|EM9|DDDDDdd|0 ~~ 99999.15|
333 |=B|EMA|DDDDDdd|0 ~~ 99999.15|
334 |=B|EMB|DDDDDdd|0 ~~ 99999.15|
335 |=B|EMC|DDDDDdd|0 ~~ 99999.15|
336 |=B|Lamp|D|0~~0|
337
338 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**
339 |=W|W|DDDDD|0 ~~ 99999
340 |=W|D|DDDDD|0 ~~ 99999
341 |=W|H|DDDDD|0 ~~ 99999
342 |=W|A|DDDDD|0 ~~ 99999
343 |=W|T|DDDDD|0 ~~ 99999
344 |=W|C|DDDDD|0 ~~ 99999
345 |=W|CIO|DDDDD|0 ~~ 99999
346 |=W|EM0|DDDDD|0 ~~ 99999
347 |=W|EM1|DDDDD|0 ~~ 99999
348 |=W|EM2|DDDDD|0 ~~ 99999
349 |=W|EM3|DDDDD|0 ~~ 99999
350 |=W|EM4|DDDDD|0 ~~ 99999
351 |=W|EM5|DDDDD|0 ~~ 99999
352 |=W|EM6|DDDDD|0 ~~ 99999
353 |=W|EM7|DDDDD|0 ~~ 99999
354 |=W|EM8|DDDDD|0 ~~ 99999
355 |=W|EM9|DDDDD|0 ~~ 99999
356 |=W|EMA|DDDDD|0 ~~ 99999
357 |=W|EMB|DDDDD|0 ~~ 99999
358 |=W|EMC|DDDDD|0 ~~ 99999
359 |=W|IR|DDDDD|0 ~~ 99999
360 |=W|DR|DDDDD|0 ~~ 99999
361
362 **Wiring Diagram:**
363
364 **RS-485**
365
366 {{id name="I3.1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a94192ee427e053b.png||alt="3.1.png" height="186" width="546"]]
367
368 Pin Definition Diagram
369
370 {{id name="I3.2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4da7b3277467c9a6.png||alt="3.2.png" height="408" width="593"]]
371
372 **RS-232**
373
374 CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
375
376 Communication Module:
377
378 CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
379
380 The serial port pin assignments may vary between HMI models, please click the following link for more information.
381
382 {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]]
383
384 == {{id name="HOMRONHOSTLINK"/}}**OMRON HOSTLINK** ==
385
386 Supported series: Omron C200HE series
387
388 **HMI Settings(recommended)**
389
390 |=Item|=Recommended
391 |=Protocol|OMRON HOSTLINK
392 |=Connection|RS232
393 |=Baud rate|9600
394 |=Stop bits|2
395 |=Data bits|7
396 |=Parity|EVEN
397 |=PLC Station No.|0
398 |=HMI Station No.|0
399
400 **Address List**
401
402 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**
403 |Bit|IR|IR|IR d|0~~99999
404 |Bit|LR|LR|LR d|0~~99999
405 |Bit|HR|HR|HR d|0~~99999
406 |Bit|AR|AR|AR d|0~~99999
407 |Bit|TIMB|TIMB|TIMB d|0~~99999
408 |Bit|CNTB|CNTB|CNTB d|0~~99999
409 |Bit|TIM|TIM|TIM d|0~~99999
410 |Bit|DM|DM|DM d|0~~99999
411 |Bit|CNT|CNT|CNT d|0~~99999
412 |Bit|WR|WR|WR d|0~~99999
413 |Bit|LAMP|LAMP|LAMP d|0~~0
414 |Word|IR|IR|IR d|0~~99999
415 |Word|LR|LR|LR d|0~~99999
416 |Word|HR|HR|HR d|0~~99999
417 |Word|AR|AR|AR d|0~~99999
418 |Word|TIM|TIM|TIM d|0~~99999
419 |Word|DM|DM|DM d|0~~99999
420 |Word|CNT|CNT|CNT d|0~~99999
421 |Word|WR|WR|WR d|0~~99999
422