Wiki source code of Omron

Last modified by Molly on 2025/12/17 16:46

Show last authors
1 = {{id name="HOmron"/}}**Omron** =
2
3 == **CJ2M Series Ethemet** ==
4
5 Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21
6
7 **HMI Settings**
8
9 |=**Items**|=**Settings**
10 |Protocol|OMRON CJ TCP FINS Ethemet
11 |Connection|Ethernet
12 |Port No.|9600
13 |Device No.|0
14 |HMI No.|0
15
16 (% id="cke_bm_1048S" style="display:none" %)** **
17
18 **Address List**
19
20 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
21 |(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999|
22 |W|W|W d|0~~99999|
23 |D|D|D d|0~~99999|
24 |H|H|H d|0~~99999|
25 |A|A|A d|0~~99999|
26 |T|T|T h|0~~99999|
27 |CF|CF|CF d|0~~99999|
28 |FF|FF|FF d|0~~99999|
29 |C|C|C d|0~~99999|
30 |EM0|EM0|EM0 d|0~~99999|
31 |EM1|EM1|EM1 d|0~~99999|
32 |EM2|EM2|EM2 d|0~~99999|
33 |EM3|EM3|EM3 d|0~~99999|
34 |EM4|EM4|EM4 d|0~~99999|
35 |EM5|EM5|EM5 h|0~~99999|
36 |EM6|EM6|EM6 d|0~~99999|
37 |EM7|EM7|EM7 d|0~~99999|
38 |EM8|EM8|EM8 d|0~~99999|
39 |EM9|EM9|EM9 d|0~~99999|
40 |EMA|EMA|EMA d|0~~99999|
41 |EMB|EMB|EMB d|0~~99999|
42 |EMC|EMC|EMC d|0~~99999|
43 |Lamp|Lamp|Lamp d|0~~0|
44 |(% colspan="1" rowspan="24" %)Word|CIO|CIO|CIO d|0~~99999|
45 |W|W|W d|0~~99999|
46 |D|D|D d|0~~99999|
47 |H|H|H d|0~~99999|
48 |A|A|A d|0~~99999|
49 |T|T|T h|0~~99999|
50 |CF|CF|CF d|0~~99999|
51 |FF|FF|FF d|0~~99999|
52 |C|C|C d|0~~99999|
53 |EM0|EM0|EM0 d|0~~99999|
54 |EM1|EM1|EM1 d|0~~99999|
55 |EM2|EM2|EM2 d|0~~99999|
56 |EM3|EM3|EM3 d|0~~99999|
57 |EM4|EM4|EM4 d|0~~99999|
58 |EM5|EM5|EM5 h|0~~99999|
59 |EM6|EM6|EM6 d|0~~99999|
60 |EM7|EM7|EM7 d|0~~99999|
61 |EM8|EM8|EM8 d|0~~99999|
62 |EM9|EM9|EM9 d|0~~99999|
63 |EMA|EMA|EMA d|0~~99999|
64 |EMB|EMB|EMB d|0~~99999|
65 |EMC|EMC|EMC d|0~~99999|
66 |IR|IR|IR d|0~~99999|
67 |DR|DR|DR d|0~~99999|
68
69 **Configure the communication protocol**
70
71 {{id name="Iimage-20220830143348-1.png"/}}
72
73 (% style="text-align:center" %)
74 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]]
75
76 {{id name="Iimage-20220830143511-2.png"/}}
77
78 (% style="text-align:center" %)
79 [[image:2.3.2.png]]
80
81 **PLC Setting:**
82
83 ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
84 Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
85
86 (% style="text-align:center" %)
87 [[image:1.3.1.png]]
88
89 ②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90
91 (% style="text-align:center" %)
92 [[image:1.3.2.png]]
93
94 ③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
95
96 [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
97 Note: Please configure the IP parameters of PLC according to the field needs
98
99 (% style="text-align:center" %)
100 [[image:1.4.png]]
101
102 ④Two rotary coding switches should be set depanding on the program paremeter:
103 a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
104
105 (% style="text-align:center" %)
106 [[image:WeCom Screenshot_20230828090604.png]]
107
108
109 **b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.**
110
111
112 (% style="text-align:center" %)
113 [[image:WeCom.png]]
114
115 **Cable Wiring**
116
117 Pin Definition Diagram
118
119 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-3"/}}
120
121 (% style="text-align:center" %)
122 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
123
124 == {{id name="HCS128CP1E2FCP1H29"/}}**CP1E Series Serial ** ==
125
126 Supported device: OMRON CS1(CP1E/CP1H)
127
128 **HMI Settings**
129
130 |=**Items**|=**Settings**|=**Note**
131 |Protocol|OMRON CS1(CP1E/CP1H)|
132 |Connection|RS232 (9600, 2, 7, EVEN)|
133 |Port No.|None|
134 |PLC station No.|0|
135
136 **Address List**
137
138 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
139 |(% colspan="1" rowspan="22" %)Bit|CIO|CIO|CIO d|0~~99999|
140 |W|W|W d|0~~99999|
141 |D|D|D d|0~~99999|
142 |H|H|H d|0~~99999|
143 |A|A|A d|0~~99999|
144 |TF|T|T h|0~~99999|
145 |CF|CF|CF d|0~~99999|
146 |T|FF|FF d|0~~99999|
147 |C|C|C d|0~~99999|
148 |EM0|EM0|EM0 d|0~~99999|
149 |EM1|EM1|EM1 d|0~~99999|
150 |EM2|EM2|EM2 d|0~~99999|
151 |EM3|EM3|EM3 d|0~~99999|
152 |EM4|EM4|EM4 d|0~~99999|
153 |EM5|EM5|EM5 h|0~~99999|
154 |EM6|EM6|EM6 d|0~~99999|
155 |EM7|EM7|EM7 d|0~~99999|
156 |EM8|EM8|EM8 d|0~~99999|
157 |EM9|EM9|EM9 d|0~~99999|
158 |EMA|EMA|EMA d|0~~99999|
159 |EMB|EMB|EMB d|0~~99999|
160 |EMC|EMC|EMC d|0~~99999|
161 |(% colspan="1" rowspan="23" %)Word|CIO|CIO|CIO d|0~~99999|
162 |W|W|W d|0~~99999|
163 |D|D|D d|0~~99999|
164 |H|H|H d|0~~99999|
165 |A|A|A d|0~~99999|
166 |T|T|T h|0~~99999|
167 |CIO|CF|CF d|0~~99999|
168 |C|C|C d|0~~99999|
169 |EM0|EM0|EM0 d|0~~99999|
170 |EM1|EM1|EM1 d|0~~99999|
171 |EM2|EM2|EM2 d|0~~99999|
172 |EM3|EM3|EM3 d|0~~99999|
173 |EM4|EM4|EM4 d|0~~99999|
174 |EM5|EM5|EM5 h|0~~99999|
175 |EM6|EM6|EM6 d|0~~99999|
176 |EM7|EM7|EM7 d|0~~99999|
177 |EM8|EM8|EM8 d|0~~99999|
178 |EM9|EM9|EM9 d|0~~99999|
179 |EMA|EMA|EMA d|0~~99999|
180 |EMB|EMB|EMB d|0~~99999|
181 |EMC|EMC|EMC d|0~~99999|
182 |IR|IR|IR d|0~~99999|
183 |DR|DR|DR d|0~~99999|
184
185 **Configure the communication protocol**
186
187 {{id name="Iimage-20220902153118-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4acef6476c6f9de3.png||alt="image-20220902153118-1.png" height="735" width="616"]]
188
189 {{id name="Iimage-20220902151322-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4f9620139b8a44b3.png||alt="image-20220902151322-2.png" height="905" width="1038"]]
190
191 **{{id name="cke_bm_27437S"/}} PLC Settings(CX-Programmer)**
192
193 Open cx-programmer, create a new PLC project or open the project that has been created.
194 Create new project: [File]→[New]→[Device Type]CP1E→[settings]→[General]→[CPU Type]N30→[OK]→[OK].
195
196 {{id name="I1.25DE57A0B65B05EFAD.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_aa70463d933c7549.png||alt="1.2 工程新建D.png" height="660" width="1134"]]
197
198 PLC Default Parameters:[Settings]→[Built-in RS232C Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link(Defaut).
199
200 {{id name="I1.34E3253E353C26570768467E5770B-914D7F6ED.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_84484fbbb00ca61.png||alt="1.3 串口参数的查看-配置D.png" height="660" width="1134"]]
201
202 **Cable Wiring**
203
204 {{id name="I56FE72473.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4c5480a409965d39.png||alt="image-20220902153949-2.png" height="508" width="2014"]]
205
206 Pin Definition Diagram
207
208 {{id name="I3.1.263A553E3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ad6138e6812c2253.png||alt="image-20220902154056-3.png" height="235" width="332"]]
209
210 == **CP2E Series Serial ** ==
211
212 Supported device:CP2E series,CP2E-N20DT-D
213
214 **HMI Settings**
215
216 |=**Items**|=**Settings**
217 |Protocol|OMRON CJ TCP FINS Ethemet
218 |Connection|Ethernet
219 |Port No.|9600
220 |Device No.|0
221 |HMI No.|0
222
223 **2.1 Create new HMI project**
224
225 Open PIStudio Software>>New Project, as shown in the figure below, set the touch screen project model and communication device type in sequence.
226
227 (% style="text-align:center" %)
228 [[image:1765960573514-689.png]]
229
230 (% class="wikigeneratedid" id="H2.2ConfigHMIcommunicationsettings" %)
231 **2.2 Config HMI communication settings**
232
233 (1) Select the protocol as CJ UDP FINS Ethernet, then set the right PLC IP and corresponding port.
234
235 For example, in this case, PLC IP is 192.168.43.101.
236
237 (% style="text-align:center" %)
238 [[image:1765960573516-574.png]]
239
240
241 1. Set the HMI IP as the same segment with PLC side. For this case, it is 192.168.43.212.
242
243 (% style="text-align:center" %)
244 [[image:1765960573517-788.png]]
245
246 1. Program the HMI screen and put PLC address.
247
248
249
250 (% style="text-align:center" %)
251 [[image:1765960573518-279.png]]
252
253 **2.3 Config PLC communication settings**
254
255 (1) Using CX Programmer P9.72 or version above to connect the PLC. Click "PLC" on toolbar, select "auto online", select "CP1/CP2 built-in Ethernet online".
256
257 [[image:1765960573518-306.png]]
258
259
260 (2) Select "Direct connection" on the pop-up window. After connecting, it will prompt whether to upload the PLC program automatically, this can be selected as user need.
261
262 (% style="text-align:center" %)
263 [[image:1765960573519-579.png]]
264
265 (3) After the connected successfully, upload the configuration settings in "Settings" from the program tree on the right side.
266
267 (% style="text-align:center" %)
268 [[image:1765960573519-497.png||height="340" width="189"]]
269
270 1. After opening the Settings , select the option "transfer from PLC" to upload the configuration information from the PLC.
271
272 (% style="text-align:center" %)
273 [[image:1765960573520-894.png||height="566" width="526"]]
274
275 Figure 2-8
276
277 1. On the built-in Ethernet(Last one tab from Settings), will see the IP address, Node number and other related information. Node number need to configured as 101, Node number does not exist in the option of 0.
278
279 (% style="text-align:center" %)
280 [[image:1765960573520-855.png||height="554" width="515"]]
281
282 1. We will see the corresponding information available on the corresponding FINS/TCP and FINS/UDP settings.
283
284 (% style="text-align:center" %)
285 [[image:1765960573521-123.png]]
286
287 (% style="text-align:center" %)
288 [[image:1765960573521-815.png]]
289
290
291 **3.Notice**
292
293 (1) The number of Ethernet nodes of Omron CP2E PLC is not set as 0 but can only start from 1. If the number of nodes is 0, the IP settings of PLC may be invalid and cannot be pinged through PC command window;
294
295 (2) After config the parameters of Ethernet, it will take effect only after power off and restart;
296
297 (3) When multiple PLCs communicate simultaneously, try to ensure that the port numbers are not duplicated.
298
299 == {{id name="HEC55Protocol"/}}**EC55 Protocol** ==
300
301 Supported device: EC55 temperature instrument
302
303 **1)HMI Settings**
304
305 |**Items**|**Settings**|**Note**
306 |Protocol|Omron EC55|
307 |Connection|RS485 (9600, 2, 7, EVEN)|
308 |Port No.|None|
309 |PLC station No.|0|
310
311 **2)Address List**
312
313 |**Type**|**Register**|**Device range**|**HMI range**|**Function**
314 |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
315 |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
316 |C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
317 |(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
318 |81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
319 |83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
320 |CP|-|0-6|Read controller intrinsic property
321 |CS|-|0-2|Read controller states
322 |CA|-|0-17|Action command
323
324 **3)Device Settings**
325
326 Omron E5CC PLC configuration
327
328 After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
329
330 {{id name="I12.PLCProtocol_html_3d95e093792ba98a.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ca4d99a0d2ffe097.png||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
331
332 According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
333
334 {{id name="I12.PLCProtocol_html_be583aa69dd6cf4c.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_984474debc119fab.png||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
335
336 **✎Note:** The communication settings for HMI should be consistent with this setting.
337
338 **Cable Wiring**
339
340 {{id name="I12.PLCProtocol_html_5e9a81a14106da9e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7b2556c42d43a768.png||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
341
342 {{id name="I12.PLCProtocol_html_1897d92be6948d58.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6d16b5adff76549.png||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
343
344 **✎Note:**
345
346 * COM3 only available in PI8000/PI9000 series.
347 * CA address could not support continuous writing function;
348 * Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
349 * When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
350 * When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
351 * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
352 * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
353 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
354 * {{id name="I12.PLCProtocol_html_d428cad280fdefb3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f434f58797d3c0da.png||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]] Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
355
356 == {{id name="HNXEtherNet2FIP"/}}**Ethernet/IP (NX/NJ Serirs)** ==
357
358 Supported series: Omron NX/NJ series
359
360 **HMI Setting**
361
362 |**Items**|**Settings**|**Note**
363 |Protocol|Omron NX/NJ Ethernet/IP|
364 |Connection|Ethernet|
365 |Port No.|44818|
366 |PLC station No.|1|
367
368 **Address list**
369
370 |=Data type|=Memo|=**Range**
371 |BOOL|1|FALSE(0) or TRUE(1)
372 |BYTE|8|0~~255
373 |WORD|16|0~~65535
374 |DWORD|32|0~~4294967295
375 |LWORD|64|0~~(2^64-1)
376 |SINT|8|-128~~127
377 |USINT|8|0~~255
378 |INT|16|-32768~~32767
379 |UINT|16|0~~65535
380 |DINT|32|-2147483648~~2147483647
381 |UDINT|32|0~~4294967295
382 |LINT|64|(-2^63)~~(2^63-1)
383 |ULINT|64|0~~(2^64-1)
384 |REAL|32|-3.402823466E+38~~3.402823466E+38
385 |LREAL|64|(((
386 -1.7976931348623158E+308~~1.79769313
387
388 48623158E+308
389 )))
390 |DATE|32|1970-01-01~~2106-02-07
391 |TIME|32|0D0H0M0S0MS~~49D17H2M47S295MS
392 |DATE_AND_TIME|32|1970-1-1-0:0:0~~2106-02-07-06:28:15
393 |TIME_OF_DAY|32|0:0:0~~23:59:59.999
394 |STRING| |
395
396 **Instruction**
397
398 1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
399
400 2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed.
401
402 (% style="text-align:center" %)
403 [[image:1725933697098-418.png]]
404
405 **Export labels from Sysmac Studio**
406
407 Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables];
408
409 (% style="text-align:center" %)
410 [[image:1725933727638-698.png]]
411
412 (% style="text-align:center" %)
413 [[image:1725933619328-454.png]]
414
415 Create a .CSV file,and Paste the [CX-Designer] into it.
416
417 (% class="box infomessage" %)
418 (((
419 **✎Note**: Make sure the CSV data is separated by commas.
420 )))
421
422 (% style="text-align:center" %)
423 [[image:1725933782144-300.png]]
424
425 Launch PIStudio, in [Communication] Settings add [Omron Ethernet/IP (NX/NJ Serirs)] protocol;
426
427 [[image:1725933826453-416.png]]
428
429 Click [Label manage];Click [Import Tags form file] and then Choose the .CSV file you need;
430
431 (% style="text-align:center" %)
432 [[image:1725933926323-707.png]]
433
434
435 **Communication Settings**
436
437 Set PLC IP in [Device IP] settings;
438
439 (% style="text-align:center" %)
440 [[image:1725934163105-489.png||height="99" width="241"]]
441
442
443 (% style="text-align:center" %)
444 [[image:1725934131262-239.png]]
445
446 **Cable Wiring**
447
448 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
449
450 == {{id name="HCV2FCJ1M2FCS1H"/}}**CJ2M Series Serial ** ==
451
452 **HMI Setting:**
453
454 |=**Parameters**|=**Recommended**
455 |=**PLC type**|OMRON CV/CJ1M/CS1H
456 |=**PLC I/F**|RS232/RS485
457 |=**Baud rate**|9600
458 |=**Data bits**|7
459 |=**Parity**|Even
460 |=**Stop bits**|2
461 |=**PLC sta. no.**|0
462
463 **PLC Setting:**
464
465 Open cx-programmer, create a new PLC project or open the project that has been created.
466 Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
467
468 {{id name="I1.265B05EFA5DE57A0B.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png||alt="1.2 新建工程.png" height="660" width="1134"]]
469
470 PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link.
471 Note:The serial port parameters should be set depending on field requirements
472
473 {{id name="I1.34E3253E353C26570914D7F6E.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d4a08b7e4dfac0bd.png||alt="1.3串口参数配置.png" height="660" width="1134"]]
474
475 **Device Address:**
476
477 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
478 |=B|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay
479 |=B|W|DDDDDdd|0 ~~65535.15|Hold Relay
480 |=B|D|DDDDDdd|0 ~~65535.15|Link Relay
481 |=B|H|DDDDDdd|0 ~~65535.15|
482 |=B|A|DDDDDdd|0 ~~65535.15|
483 |=B|TF|DDDDD|0 ~~ 99999|
484 |=B|CF|DDDDD|0 ~~ 99999|Auxiliary Relay
485 |=B|T|DDDDDdd|0 ~~65535.15|
486 |=B|C|DDDDDdd|0 ~~65535.15|
487 |=B|EM0|DDDDDdd|0 ~~ 99999.15|
488 |=B|EM1|DDDDDdd|0 ~~ 99999.15|
489 |=B|EM2|DDDDDdd|0 ~~ 99999.15|
490 |=B|EM3|DDDDDdd|0 ~~ 99999.15|
491 |=B|EM4|DDDDDdd|0 ~~ 99999.15|
492 |=B|EM5|DDDDDdd|0 ~~ 99999.15|
493 |=B|EM6|DDDDDdd|0 ~~ 99999.15|
494 |=B|EM7|DDDDDdd|0 ~~ 99999.15|
495 |=B|EM8|DDDDDdd|0 ~~ 99999.15|
496 |=B|EM9|DDDDDdd|0 ~~ 99999.15|
497 |=B|EMA|DDDDDdd|0 ~~ 99999.15|
498 |=B|EMB|DDDDDdd|0 ~~ 99999.15|
499 |=B|EMC|DDDDDdd|0 ~~ 99999.15|
500 |=B|Lamp|D|0~~0|
501
502 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**
503 |=W|W|DDDDD|0 ~~ 99999
504 |=W|D|DDDDD|0 ~~ 99999
505 |=W|H|DDDDD|0 ~~ 99999
506 |=W|A|DDDDD|0 ~~ 99999
507 |=W|T|DDDDD|0 ~~ 99999
508 |=W|C|DDDDD|0 ~~ 99999
509 |=W|CIO|DDDDD|0 ~~ 99999
510 |=W|EM0|DDDDD|0 ~~ 99999
511 |=W|EM1|DDDDD|0 ~~ 99999
512 |=W|EM2|DDDDD|0 ~~ 99999
513 |=W|EM3|DDDDD|0 ~~ 99999
514 |=W|EM4|DDDDD|0 ~~ 99999
515 |=W|EM5|DDDDD|0 ~~ 99999
516 |=W|EM6|DDDDD|0 ~~ 99999
517 |=W|EM7|DDDDD|0 ~~ 99999
518 |=W|EM8|DDDDD|0 ~~ 99999
519 |=W|EM9|DDDDD|0 ~~ 99999
520 |=W|EMA|DDDDD|0 ~~ 99999
521 |=W|EMB|DDDDD|0 ~~ 99999
522 |=W|EMC|DDDDD|0 ~~ 99999
523 |=W|IR|DDDDD|0 ~~ 99999
524 |=W|DR|DDDDD|0 ~~ 99999
525
526 **Wiring Diagram:**
527
528 **RS-485**
529
530 {{id name="I3.1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a94192ee427e053b.png||alt="3.1.png" height="186" width="546"]]
531
532 Pin Definition Diagram
533
534 {{id name="I3.2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4da7b3277467c9a6.png||alt="3.2.png" height="408" width="593"]]
535
536 **RS-232**
537
538 CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
539
540 Communication Module:
541
542 CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
543
544 The serial port pin assignments may vary between HMI models, please click the following link for more information.
545
546 {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]]
547
548 == C200HE Series Serial ==
549
550 Supported series: Omron C200HE series
551
552 **HMI Settings(recommended)**
553
554 |=Item|=Recommended
555 |=Protocol|OMRON HOSTLINK
556 |=Connection|RS232
557 |=Baud rate|9600
558 |=Stop bits|2
559 |=Data bits|7
560 |=Parity|EVEN
561 |=PLC Station No.|0
562 |=HMI Station No.|0
563
564 **Address List**
565
566 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**
567 |Bit|IR|IR|IR d|0~~99999
568 |Bit|LR|LR|LR d|0~~99999
569 |Bit|HR|HR|HR d|0~~99999
570 |Bit|AR|AR|AR d|0~~99999
571 |Bit|TIMB|TIMB|TIMB d|0~~99999
572 |Bit|CNTB|CNTB|CNTB d|0~~99999
573 |Bit|TIM|TIM|TIM d|0~~99999
574 |Bit|DM|DM|DM d|0~~99999
575 |Bit|CNT|CNT|CNT d|0~~99999
576 |Bit|WR|WR|WR d|0~~99999
577 |Bit|LAMP|LAMP|LAMP d|0~~0
578 |Word|IR|IR|IR d|0~~99999
579 |Word|LR|LR|LR d|0~~99999
580 |Word|HR|HR|HR d|0~~99999
581 |Word|AR|AR|AR d|0~~99999
582 |Word|TIM|TIM|TIM d|0~~99999
583 |Word|DM|DM|DM d|0~~99999
584 |Word|CNT|CNT|CNT d|0~~99999
585 |Word|WR|WR|WR d|0~~99999
586
587 **Cable Wiring**
588
589 {{id name="I3.1.263A553E3.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ad6138e6812c2253.png||alt="3.1.2 接口.png" height="240" width="339"]]