Panasonic
Panasonic
FP Series Serial
1)HMI Settings
Item | Settings | Note |
Protocol | Panasonic FP MEWTOCOL | |
Connection | RS232 | |
Baud rate | 9600 | |
Data bit | 8 | |
Parity | ODD | |
Stop bit | 1 | |
PLC station No. | 1 |
2)Address List
Type | Device registers | Format | Range | Note |
Bit | X | X d | 0~9999 | |
Bit | Y | Y d | 0~9999 | |
Bit | R | R d | 0~9999 | |
Bit | T | T d | 0~9999 | |
Bit | C | C d | 0~9999 | |
Bit | L | L d | 0~9999 | |
Word | WX | WX d | 0~9999 | |
Word | WY | WY d | 0~9999 | |
Word | WR | WR d | 0~9999 | |
Word | WL | WL d | 0~9999 | |
Word | LD | LD d | 0~9999 | |
Word | DT | DT d | 0~65535 | |
Word | FL | FL d | 0~9999 | |
Word | EV | EV d | 0~9999 | |
Word | SV | SV d | 0~9999 |
3)Configure the communication protocol
5)PLC Setting:
①PLC Default Parameters:
1.[Option]→[System register settings]→[COM0 Port]→[Unit No.]1→[Communication Mode]Computer Link → [Baud Rate]9600bps → [Communication Format]char.bit:8bits;Parity:Odd;Stop Bit:1→[OK].
②[Online]→[Communication Settings]→[Port to use]COM(USB)→[Port to use (No.)]PIDSX PLC USB-COM(COM12)→[Communications condition settings] Communications speed:9600bps;Data
length:8bits;Stop bits:1bit;Parity:Odd;Timeout (sec):5→[Automatic search items in communications conditions]:check the option[Communications speed],[ Data length],[ Parity]→[OK]
Please select according to the actual connection between PC and PLC.
5)Cable Wiring
Figure
Pin Definition Diagram
FP Series Ethernet
HMI Settings
Item | Settings | Note |
Protocol | Panasonic FP MEWTOCOL(Ethernet) | |
Connection | Ethernet | |
Port No. | 32769 | |
Network | TCP_Client_2N | |
PLC station No. | 1 |
Address List
Type | Device registers | Format | Range | Note |
Bit | X | X d | 0~9999 | |
Bit | Y | Y d | 0~9999 | |
Bit | R | R d | 0~9999 | |
Bit | T | T d | 0~9999 | |
Bit | C | C d | 0~9999 | |
Bit | L | L d | 0~9999 | |
Word | WX | WX d | 0~9999 | |
Word | WY | WY d | 0~9999 | |
Word | WR | WR d | 0~9999 | |
Word | WL | WL d | 0~9999 | |
Word | LD | LD d | 0~9999 | |
Word | DT | DT d | 0~65535 | |
Word | FL | FL d | 0~9999 | |
Word | EV | EV d | 0~9999 | |
Word | SV | SV d | 0~9999 |
Configure the communication protocol
PLC Setting:
1.[Option]→[Ethernet settings]→[Basic communications information]→[IPv4 address autonatic acquisition]No → [Home IP address]192.168.40.11 → [Subnet mask]255.255.255.0 → [Default gateway]192.168.40.1
2.[ System connecton settings] →[Home port nunber]32769→[OK].
Note: Please configure the IP parameters of PLC according to the field needs
Cable Wiring
Pin Definition Diagram