= {{id name="HSchneider"/}}**Schneider** = |
2 |
2 |
|
3 |
|
-== {{id name="HSchneiderMODBUSRTU"/}}**MODBUS RTU** == |
|
3 |
+== {{id name="HSchneiderMODBUSRTU"/}}**Schneider MODBUS RTU** == |
4 |
4 |
|
5 |
5 |
**HMI Setting** |
6 |
6 |
|
7 |
7 |
|=**Parameters**|=**Recommended**|=**Notes** |
8 |
|
-|=**Protocol**|Schneider MODBUS RTU| |
9 |
|
-|=Connection|RS485| |
10 |
|
-|=**Baud rate**|19200| |
11 |
|
-|=**Data bit**|8| |
12 |
|
-|=**Parity**|Even| |
13 |
|
-|=**Stop bit**|1| |
14 |
|
-|=**PLC station No.**|1| |
|
8 |
+|**Protocol**|Schneider MODBUS RTU| |
|
9 |
+|Connection|RS485| |
|
10 |
+|**Baud rate**|19200| |
|
11 |
+|**Data bit**|8| |
|
12 |
+|**Parity**|Even| |
|
13 |
+|**Stop bit**|1| |
|
14 |
+|**PLC station No.**|1| |
15 |
15 |
|
16 |
16 |
**PLC Setting** |
17 |
17 |
|
... |
... |
@@ -31,60 +31,3 @@ |
31 |
31 |
**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector. |
32 |
32 |
|
33 |
33 |
{{id name="Iimage-20220817154212-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c74587d16cc7ee2.jpg||alt="image-20220817154212-1.jpeg" height="315" width="554"]] |
34 |
|
- |
35 |
|
-== **TM218 series** == |
36 |
|
- |
37 |
|
- |
38 |
|
-**HMI Setting** |
39 |
|
- |
40 |
|
-|=**Parameters**|=**Recommended**|=**Notes** |
41 |
|
-|**Protocol**|Schneider Modicon MODBUS RTU| |
42 |
|
-|Connection|RS485| |
43 |
|
-|**Baud rate**|19200| |
44 |
|
-|**Data bit**|8| |
45 |
|
-|**Parity**|Even| |
46 |
|
-|**Stop bit**|1| |
47 |
|
-|**PLC station No.**|1 |
48 |
|
- |
49 |
|
-**Device Address** |
50 |
|
- |
51 |
|
-|=**Bit/Word**|=**Device type**|=**Format**|=**Range** |
52 |
|
-|B|IX|IX dddd.d|0 ~~ 65535 |
53 |
|
-|B|QX|QX dddd.d|0 ~~ 65535 |
54 |
|
-|B|MX|MX dddd.dd|0 ~~ 999999 |
55 |
|
-|W|MW|MW dddd|0 ~~ 999999 |
56 |
|
- |
57 |
|
- **Configure the communication protocol** |
58 |
|
- |
59 |
|
-(% style="text-align:center" %) |
60 |
|
-[[image:11.png]] |
61 |
|
- |
62 |
|
-(% style="text-align:center" %) |
63 |
|
-[[image:12.png]] |
64 |
|
- |
65 |
|
-**PLC Setting:** |
66 |
|
- |
67 |
|
-Open SoMachine Central, create a new project or open the project that has been created. |
68 |
|
- |
69 |
|
-Create new project: [Create a new project]→[Empty Project]→[OK]→[Open Configuration] |
70 |
|
- |
71 |
|
-(% style="text-align:center" %) |
72 |
|
-[[image:2.png]] |
73 |
|
- |
74 |
|
-(% style="text-align:center" %) |
75 |
|
-[[image:3.png]] |
76 |
|
- |
77 |
|
-Into the [Open Configuration].[Untitled]→[Add Device]→[Logic Controller]→[M218]→[TM218LDA16DRN] |
78 |
|
- |
79 |
|
-(% style="text-align:center" %) |
80 |
|
-[[image:4.png]] |
81 |
|
- |
82 |
|
-PLC Default Parameters:In the Devices tree [MyController]→[Serial Line 2]→[Modbus_Manager]→[Transmission Mode]:RTU→[Addressing]:Slave→[Serial Line Settings]:[Baud rate] 19200, [Data bits]8, [Stop bits]1,[Parity] EVEN,[Physical Medium] RS485 |
83 |
|
- |
84 |
|
-(% style="text-align:center" %) |
85 |
|
-[[image:5.png]] |
86 |
|
- |
87 |
|
- **Cable Wiring** |
88 |
|
- |
89 |
|
-(% style="text-align:center" %) |
90 |
|
-[[image:1711078732764-435.png]] |