Changes for page Schneider

Last modified by Mora Zhou on 2024/03/23 14:16

From version 6.1
edited by Jett
on 2024/03/22 12:01
Change comment: There is no comment for this version
To version 11.1
edited by Mora Zhou
on 2024/03/23 14:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.2454238480
1 +XWiki.Mora
Content
... ... @@ -1,17 +1,17 @@
1 1  = {{id name="HSchneider"/}}**Schneider** =
2 2  
3 -== {{id name="HSchneiderMODBUSRTU"/}}**Schneider MODBUS RTU** ==
3 +== {{id name="HSchneiderMODBUSRTU"/}}**MODBUS RTU** ==
4 4  
5 5  **HMI Setting**
6 6  
7 7  |=**Parameters**|=**Recommended**|=**Notes**
8 -|**Protocol**|Schneider MODBUS RTU|
9 -|Connection|RS485|
10 -|**Baud rate**|19200|
11 -|**Data bit**|8|
12 -|**Parity**|Even|
13 -|**Stop bit**|1|
14 -|**PLC station No.**|1|
8 +|=**Protocol**|Schneider MODBUS RTU|
9 +|=Connection|RS485|
10 +|=**Baud rate**|19200|
11 +|=**Data bit**|8|
12 +|=**Parity**|Even|
13 +|=**Stop bit**|1|
14 +|=**PLC station No.**|1|
15 15  
16 16  **PLC Setting**
17 17  
... ... @@ -32,64 +32,71 @@
32 32  
33 33  {{id name="Iimage-20220817154212-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c74587d16cc7ee2.jpg||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
34 34  
35 -== **Schneider TM218 series** ==
35 +== **TM218 series** ==
36 36  
37 37  
38 38  **HMI Setting**
39 39  
40 40  |=**Parameters**|=**Recommended**|=**Notes**
41 -|**Protocol**|Schneider Modicon MODBUS RTU|
42 -|Connection|RS485|
43 -|**Baud rate**|19200|
44 -|**Data bit**|8|
45 -|**Parity**|Even|
46 -|**Stop bit**|1|
47 -|**PLC station No.**|1
41 +|=**Protocol**|Schneider Modicon MODBUS RTU|
42 +|=Connection|RS485|
43 +|=**Baud rate**|19200|
44 +|=**Data bit**|8|
45 +|=**Parity**|Even|
46 +|=**Stop bit**|1|
47 +|=**PLC station No.**|1
48 48  
49 49  **Device Address**
50 50  
51 51  |=**Bit/Word**|=**Device type**|=**Format**|=**Range**
52 -|B|IX|IX dddd.d|0 ~~ 65535
53 -|B|QX|QX dddd.d|0 ~~ 65535
54 -|B|MX|MX dddd.dd|0 ~~ 999999
55 -|W|MW|MW dddd|0 ~~ 999999
52 +|B|IX|IX dddd.d|0 to 65535
53 +|B|QX|QX dddd.d|0 to 65535
54 +|B|MX|MX dddd.dd|0 to 999999
55 +|W|MW|MW dddd|0 to 999999
56 56  
57 57   **Configure the communication protocol**
58 58  
59 59  (% style="text-align:center" %)
60 -[[image:1711078502000-977.png]]
60 +[[image:11.png]]
61 61  
62 62  (% style="text-align:center" %)
63 -[[image:1711078509511-443.png]]
63 +[[image:12.png]]
64 64  
65 65  **PLC Setting:**
66 66  
67 67  Open SoMachine Central, create a new project or open the project that has been created.
68 68  
69 -Create new project: [Create a new project]→[Empty Project]→[OK]→[Open Configuration]
69 +Create new project: [Create a new project]→[Empty Project]→[OK]→[Open Configuration]
70 70  
71 71  (% style="text-align:center" %)
72 -[[image:1711078656040-781.png]]
72 +[[image:2.png]]
73 73  
74 74  (% style="text-align:center" %)
75 -[[image:1711078662048-425.png]]
75 +[[image:3.png]]
76 76  
77 -Into the [Open Configuration].[Untitled]→[Add Device]→[Logic Controller]→[M218]→[TM218LDA16DRN]
77 +Into the [Open Configuration].
78 78  
79 +[Untitled]→[Add Device]→[Logic Controller]→[M218]→[TM218LDA16DRN]
80 +
79 79  (% style="text-align:center" %)
80 -[[image:1711078686235-785.png]]
82 +[[image:4.png]]
81 81  
82 -PLC Default Parameters:In the Devices tree [MyController]→[Serial Line 2]→[Modbus_Manager]→[Transmission Mode]:RTU→[Addressing]:Slave→[Serial Line Settings]:[Baud rate] 19200, [Data bits]8, [Stop bits]1,[Parity] EVEN,[Physical Medium] RS485
84 +PLC Default Parameters:
83 83  
84 -(% style="text-align:center" %)
85 -[[image:1711078600047-723.png]]
86 +In the Devices tree [MyController]→[Serial Line 2]→[Modbus_Manager]
86 86  
87 - **Cable Wiring**
88 +Modbus:
88 88  
90 +[Transmission Mode] RTU→[Addressing] Slave
91 +
92 +Serial Line Settings:
93 +
94 +[Baud rate] 19200, [Data bits] 8, [Stop bits] 1, [Parity] EVEN, [Physical Medium] RS485
95 +
89 89  (% style="text-align:center" %)
90 -[[image:1711078719633-316.png]]
97 +[[image:5.png]]
91 91  
92 -Pin Definition Diagram:
99 + **Cable Wiring**
93 93  
94 94  (% style="text-align:center" %)
95 95  [[image:1711078732764-435.png]]
11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +104.1 KB
Content
12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +116.8 KB
Content
2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +48.2 KB
Content
3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +90.6 KB
Content
4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +67.0 KB
Content
5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.2454238480
Size
... ... @@ -1,0 +1,1 @@
1 +63.2 KB
Content