Xinje

Version 14.1 by Hunter on 2023/09/22 13:45

XC MODBUS

HMI Settings

ItemSettingsNote
ProtocolXINJE XC MODBUS 
ConnectionRS232 
Baud rate19200 
Data bit8 
ParityEVEN 
Stop bit1 
PLC station No.1 

Address List

TypeDevice registersHMI registersFormatRangeNote
BitMMM d0~8511 
BitXXX o0~1747 
BitYYY o0~1747 
BitSSS d0~1023 
BitTTT d0~4095 
BitCCC d0~634 
WordDDD d0~8511 
WordTDTDTD d0~618 
WordCDCDCD d0~634 
WordFDFDFD d0~8511 

Configure the communication protocol

image-20220830154105-1.png

image-20220830154159-3.png

Cable Wiring

Figure

image-20220830155728-4.png

Pin Definition Diagram

image-20220830154131-2.png

XD/XE MODBUS

Supported Series: Xinjie XD Series

HMI Settings

ItemSettingsNote
ProtocolXINJE XD/XC MODBUS 
ConnectionRS232 
Baud rate19200 
Data bit8 
ParityEVEN 
Stop bit1 
PLC station No.1Need to be same as PLC setting

Address List

TypeDevice registersFormatRangeNote
BitMMDDDDD0~74999 
X1xxX1xxOOOO0~1177 
X2xxX2xxOOO0~277 
XXOO0~77 
Y1xxY1xxOOOO0~1177 
Y2xxY2xxOOO0~277 
YYOOOO0~77 
SMSMDDDD0~4999 
TTDDDD0~4999 
CCDDDD0~4999 
ETETDD0~31 
SESEDD0~31 
HMHMDDDDD0~11999 
HSCHSCDD0~39 
HSHSDDD0~999 
HTHTDDDD0~1999 
HCHCDDDD0~1999 
SSDDDD0~7999 
WordDDDDDDD0~69999 
IDIDDD0~99 
ID1xxID1xxDDD0~999 
ID2xxID2xxDDD0~299 
QDQDDD0~99 
QD1xxQD1xxDDD0~999 
QD2xxQD2xxDDD0~299 
SDSDDDDD0~4999 
TDTDDDD0~575 
CDCDDDD0~575 
ETDETDDD0~31 
HDHDDDDDD0~24999 
HSDHSDDDDD0~1023 
HTDHTDDD0~95 
HCDHCDDD0~95 
HSCDHSCDDD0~31 
FDFDDDDD0~8191 
SFDSFDDDDD0~5999 
FSFSDD0~47 

PLC Settings

Create the new project, and select the specific model according to the actual PLC

XinjieXDcreatenew.png

Program the PLC

XinjieXDLDprg.png

Connect PLC with PC through RS232-USB converter cable. Click [Option]-[Software Serial Port Config]-[Communication configuration] to open the PC connection configuration.

XinjieXDopenSWcom.png

New a Modbus configuration, and Click [Comm-Test] to test connection, if shows "Connect To PLC Succeeded", which means PLC connection set up successfully. And click OK to save the settings

XinjieXDPLCtestconn.png

Remember to click the Status cell of new created Modbus configuration for change the status into "in use", then click OK to exit.

XinjieXDclickto.png

After done the previous steps, it would prompt like the below

XinjieXDsuccessprompt.png

Change the PLC communication setup if required. Click [Configure]-[PLC Comm Port Settings]-[Add]-[Modbus]. After parameters are modified, click [Write to PLC].

XinjieXDSetPLCcom0.png

If wrote to PLC successfully, it would prompt like the below

XinjieXDwriteComparadone.png

Click [Online]-[Download Program & Data], and wait for a while, the pop up window would ask for whether to stop PLC, and click [Stop PLC, contitue download]

XinjieXDdownload.png

And then the XDPro ask for which options want to rewrite, and click OK to finish.

XinjieXDdownloadopt.png

If download successfully, it would prompt like the below

XinjieXDcomplete.png

Cable Wiring

Xinjie.gif