@@ -1,14 +3,12 @@ |
1 |
|
-**Wecon V-BOX R Series User Manual** |
2 |
|
- |
3 |
3 |
== **1 Product description** == |
4 |
4 |
|
5 |
|
-|**Series**|**Model**|**Description** |
6 |
|
-|(% rowspan="3" %)**R Series**|RE-00|1 network port, single serial port |
7 |
|
-|RE-4G|1 network port, single serial port, support 4G. |
8 |
|
-|RH-WF|((( |
|
3 |
+|**Series**|(% style="width:132px" %)**Model**|(% style="width:552px" %)**Description** |
|
4 |
+|(% rowspan="3" %)**R Series**|(% style="width:132px" %)RE-00|(% style="width:552px" %)1 network port, single serial port |
|
5 |
+|(% style="width:132px" %)RE-4G|(% style="width:552px" %)1 network port, single serial port, support 4G. |
|
6 |
+|(% style="width:132px" %)RH-WF|(% style="width:552px" %)((( |
9 |
9 |
2 network ports, 1 HDMI interface, single serial port, 2 RS485 terminals, support WiFi |
10 |
10 |
|
11 |
|
-2 optocoupler isolated input (DI), 2relay output (DO) |
|
9 |
+2 optocoupler isolated input (DI), 2 relay output (DO) |
12 |
12 |
))) |
13 |
13 |
|
14 |
14 |
=== **1.1 Product appearance** === |
... |
... |
@@ -15,11 +15,11 @@ |
15 |
15 |
|
16 |
16 |
==== **(1)RE-00/RE-4G** ==== |
17 |
17 |
|
18 |
|
-[[image:Wecon V-BOX R Series User Manual 240611 V1.2_eae14981.png||height="305" width="273"]] |
|
16 |
+[[image:1723447082795-273.png]] |
19 |
19 |
|
20 |
20 |
RE-00/RE-4G Appearance |
21 |
21 |
|
22 |
|
-[[image:Wecon V-BOX R Series User Manual 240611 V1.2_59f1285c.gif||height="259" width="643"]] |
|
20 |
+[[image:1723447096815-592.png]] |
23 |
23 |
|
24 |
24 |
RE-00/RE-4G Installation Dimensions |
25 |
25 |
|
... |
... |
@@ -35,17 +35,14 @@ |
35 |
35 |
|
36 |
36 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]] |
37 |
37 |
|
38 |
|
-Installation Size |
|
36 |
+Installation size |
39 |
39 |
|
40 |
40 |
|
41 |
|
- |
42 |
|
- |
43 |
|
- |
44 |
|
- |
45 |
45 |
=== **1.2 Product specifications** === |
46 |
46 |
|
47 |
47 |
((( |
48 |
|
-|(% colspan="3" %)**Model/Specifications**|**RE-00**|**RE-4G**|**RH-WF** |
|
42 |
+(% style="width:815px" %) |
|
43 |
+|=(% colspan="3" %)**Model/Specifications**|=**RE-00**|=**RE-4G**|=**RH-WF** |
49 |
49 |
|(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters** |
50 |
50 |
|(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz |
51 |
51 |
|(% rowspan="3" %)Memory|(% colspan="2" %)Flash|(% colspan="2" %)128MB|8GB |
... |
... |
@@ -106,17 +106,14 @@ |
106 |
106 |
|(% colspan="2" %)VPN Pass trough|(% colspan="3" %)Yes |
107 |
107 |
|(% colspan="2" %)API interface|(% colspan="3" %)Yes |
108 |
108 |
|
109 |
|
-**1.3 Interface Description** |
|
104 |
+=== **1.3 Interface Description** === |
110 |
110 |
))) |
111 |
111 |
|
112 |
|
-==== **(1)Appearance component description** ==== |
|
107 |
+==== **(1) Appearance component description** ==== |
113 |
113 |
|
114 |
|
-* |
115 |
|
-** |
116 |
|
-*** |
117 |
|
-**** **RE-00/RE-4G** |
|
109 |
+**RE-00/RE-4G** |
118 |
118 |
|
119 |
|
-[[image:Wecon V-BOX R Series User Manual 240611 V1.2_9ade4359.gif||height="203" width="643"]] |
|
111 |
+[[image:1723448311561-814.png]] |
120 |
120 |
|
121 |
121 |
RE-00/RE-4G Component Description |
122 |
122 |
|
... |
... |
@@ -124,12 +124,9 @@ |
124 |
124 |
|**1**|Indicator lamp|**2**|Micro-USB|**3**|Ethernet port|**4**|COM port |
125 |
125 |
|**5**|Power supply|**6**|4G antenna (Optional)|**7**|Fixed fastener|**8**|SIM card (Optional) |
126 |
126 |
|
127 |
|
-* |
128 |
|
-** |
129 |
|
-*** |
130 |
|
-**** **RH-WF** |
|
119 |
+**RH-WF** |
131 |
131 |
|
132 |
|
-[[image:Wecon V-BOX R Series User Manual 240611 V1.2_906b0210.gif||height="281" width="642"]] |
|
121 |
+[[image:1723448356737-113.png]] |
133 |
133 |
|
134 |
134 |
RH-WF Component Description |
135 |
135 |
|
... |
... |
@@ -137,12 +137,9 @@ |
137 |
137 |
|**5**|HDMI|**6**|TYPE-C|**7**|COM port|**8**|I/O interface and RS485 terminal |
138 |
138 |
|**9**|Power supply|**10**|WIFI antenna|**11**|Fixed fastener| | |
139 |
139 |
|
140 |
|
-==== {{id name="_Toc24573"/}}**(2)Interface Description** ==== |
|
129 |
+==== **(2) Interface Description** ==== |
141 |
141 |
|
142 |
|
-* |
143 |
|
-** |
144 |
|
-*** |
145 |
|
-**** **RE-00/RE-4G** |
|
131 |
+**RE-00/RE-4G** |
146 |
146 |
|
147 |
147 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d215ad34.png||height="276" width="616"]] |
148 |
148 |
|
... |
... |
@@ -150,17 +150,11 @@ |
150 |
150 |
**RH-WF** |
151 |
151 |
|
152 |
152 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]] |
153 |
|
-[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="301" width="613"]] |
154 |
|
- |
155 |
155 |
|
|
140 |
+==== **(3) Interface Definition** ==== |
156 |
156 |
|
157 |
|
-==== {{id name="_Toc26179"/}}**(3) Interface Definition** ==== |
|
142 |
+**RE-00/RE-4G COM1 interface definition** |
158 |
158 |
|
159 |
|
-* |
160 |
|
-** |
161 |
|
-*** |
162 |
|
-**** **RE-00/RE-4G COM1 interface definition** |
163 |
|
- |
164 |
164 |
|**Pin**|**Definition**|**Pin**|**Definition** |
165 |
165 |
|1|RS422 TX+/RS485 A+|2|RS232 RXD |
166 |
166 |
|3|RS232 TXD|5|GND |
... |
... |
@@ -167,10 +167,7 @@ |
167 |
167 |
|6|RS422 TX-/RS485 B-|8|RS422 RX- |
168 |
168 |
|9|RS422 RX+| | |
169 |
169 |
|
170 |
|
-* |
171 |
|
-** |
172 |
|
-*** |
173 |
|
-**** **RH-WF** |
|
150 |
+**RH-WF** |
174 |
174 |
|
175 |
175 |
|(% colspan="2" %)**Pin**|**Definition** |
176 |
176 |
|(% rowspan="7" %)[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ef6a7104.gif||height="205" width="93"]]|S/S|((( |
... |
... |
@@ -187,11 +187,11 @@ |
187 |
187 |
|485-|RS485- |
188 |
188 |
|GND|Ground |
189 |
189 |
|
190 |
|
-== {{id name="_Toc22666"/}}{{id name="_Toc30723"/}}**2 Applications** == |
|
167 |
+== **2 Applications** == |
191 |
191 |
|
192 |
|
-R series products,which can easily realize advanced requirements such as real-time display on industrial sites. |
|
169 |
+R series products, which can easily realize advanced requirements such as real-time display on industrial sites. |
193 |
193 |
|
194 |
|
-{{id name="_GoBack"/}}[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]] |
|
171 |
+[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]] |
195 |
195 |
|
196 |
196 |
① Large-screen display, connect computer/TV Display the project screen; |
197 |
197 |
|
... |
... |
@@ -199,9 +199,9 @@ |
199 |
199 |
|
200 |
200 |
③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software. |
201 |
201 |
|
202 |
|
-== {{id name="_Toc12278"/}}{{id name="_Toc1407"/}}**3 Operation Instructions** == |
|
179 |
+== **3 Operation Instructions** == |
203 |
203 |
|
204 |
|
-=== {{id name="_Toc17286"/}}{{id name="_Toc19484"/}}**3.1 Project Download-PIStudio** === |
|
181 |
+=== **3.1 Project Download-PIStudio** === |
205 |
205 |
|
206 |
206 |
**(1) New project** |
207 |
207 |
|
... |
... |
@@ -230,9 +230,9 @@ |
230 |
230 |
|
231 |
231 |
**Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.** |
232 |
232 |
|
233 |
|
-=== {{id name="_Toc5083"/}}{{id name="_Toc2542"/}}**3.2 Check V-NET IoT System** === |
|
210 |
+=== **3.2 Check V-NET IoT System** === |
234 |
234 |
|
235 |
|
-==== {{id name="_Toc22900"/}}**3.2.1 V-NET login** ==== |
|
212 |
+==== **3.2.1 V-NET login** ==== |
236 |
236 |
|
237 |
237 |
(1) New users must register first, and after the registration is successful, the user can use it. |
238 |
238 |
|
... |
... |
@@ -248,7 +248,7 @@ |
248 |
248 |
|
249 |
249 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]] |
250 |
250 |
|
251 |
|
-==== {{id name="_Toc22039"/}}**3.2.2 Adding devices** ==== |
|
228 |
+==== **3.2.2 Adding devices** ==== |
252 |
252 |
|
253 |
253 |
(1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar. |
254 |
254 |
|
... |
... |
@@ -270,7 +270,7 @@ |
270 |
270 |
|
271 |
271 |
(3) Binding device is successful, click OK, prompt: Bind device successful! |
272 |
272 |
|
273 |
|
-==== {{id name="_Toc25660"/}}**3.2.3 V-NET check** ==== |
|
250 |
+==== **3.2.3 V-NET check** ==== |
274 |
274 |
|
275 |
275 |
**(1) Remote monitoring** |
276 |
276 |
|
... |
... |
@@ -331,12 +331,12 @@ |
331 |
331 |
|
332 |
332 |
②Use manual positioning. |
333 |
333 |
|
334 |
|
-Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync. |
|
311 |
+**Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.** |
335 |
335 |
|
336 |
336 |
|
337 |
|
-== {{id name="_Toc7609"/}}{{id name="_Toc19227"/}}**3 Pass-through of device** == |
|
314 |
+== **3 Pass-through of device** == |
338 |
338 |
|
339 |
|
-{{id name="_Toc16958"/}}{{id name="_Toc18341"/}}{{id name="_Toc10036"/}}{{id name="_Toc14306"/}}{{id name="_Toc8318"/}}{{id name="_Toc23343"/}}{{id name="_Toc11131"/}}{{id name="_Toc21238"/}}{{id name="_Toc23066"/}}{{id name="_Toc22286"/}}{{id name="_Toc32206"/}}{{id name="_Toc14201"/}}{{id name="_Toc5622"/}}{{id name="_Toc10379"/}}{{id name="_Toc29542"/}}{{id name="_Toc3580"/}}{{id name="_Toc20482"/}}{{id name="_Toc22905"/}}{{id name="_Toc10700"/}}{{id name="_Toc2060"/}}{{id name="_Toc10051"/}}**Note: The pass-through operation steps of V-NET/V-IEC are for reference only.** |
|
316 |
+**Note: The pass-through operation steps of V-NET/V-IEC are for reference only.** |
340 |
340 |
|
341 |
341 |
Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc. |
342 |
342 |
|
... |
... |
@@ -344,15 +344,15 @@ |
344 |
344 |
|
345 |
345 |
Device status description table is as follows: |
346 |
346 |
|
347 |
|
-|**Color**|**Color Value (HEX)**|**Status**|**Description** |
348 |
|
-|●|#18E600|Online|Pass-through available |
349 |
|
-|●|#B5C1D8|Offline|Pass-through is not allowed |
350 |
|
-|●|#1C9BFD|Pass-through connecting|In pass-through |
351 |
|
-|●|#005CFF|VPN connecting|In pass-through |
352 |
|
-|●|#FD8B09|VPN pass-through is reconnecting|Pass-through reconnecting due to network and other reasons |
353 |
|
-|●|#2C405E|VPN pass-through is ending|The end of pass-through due to [End pass-through] |
354 |
|
-|●|#109A00|Download is ready.|Download channel is ready. (Download can be executed.) |
355 |
|
-|●|#009577|Download|In download |
|
324 |
+|(% style="width:82px" %)**Color**|(% style="width:248px" %)**Color Value (HEX)**|**Status**|**Description** |
|
325 |
+|(% style="width:82px" %)[[image:1723449592784-532.png]]|(% style="width:248px" %)#18E600|Online|Pass-through available |
|
326 |
+|(% style="width:82px" %)[[image:1723449624928-809.png]]|(% style="width:248px" %)#B5C1D8|Offline|Pass-through is not allowed |
|
327 |
+|(% style="width:82px" %)[[image:1723449706265-533.png]]|(% style="width:248px" %)#1C9BFD|Pass-through connecting|In pass-through |
|
328 |
+|(% style="width:82px" %)[[image:1723449737329-134.png||height="28" width="31"]]|(% style="width:248px" %)#005CFF|VPN connecting|In pass-through |
|
329 |
+|(% style="width:82px" %)[[image:1723449765210-888.png]]|(% style="width:248px" %)#FD8B09|VPN pass-through is reconnecting|Pass-through reconnecting due to network and other reasons |
|
330 |
+|(% style="width:82px" %)[[image:1723449785743-305.png||height="28" width="32"]]|(% style="width:248px" %)#2C405E|VPN pass-through is ending|The end of pass-through due to [End pass-through] |
|
331 |
+|(% style="width:82px" %)[[image:1723449827434-119.png]]|(% style="width:248px" %)#109A00|Download is ready.|Download channel is ready. (Download can be executed.) |
|
332 |
+|(% style="width:82px" %)[[image:1723449809049-353.png]]|(% style="width:248px" %)#009577|Download|In download |
356 |
356 |
|
357 |
357 |
**Pass-through precautions:** |
358 |
358 |
|
... |
... |
@@ -367,7 +367,7 @@ |
367 |
367 |
● When the current user has a device in pass-through, “Start pass-through” cannot be clicked. |
368 |
368 |
|
369 |
369 |
|
370 |
|
-=== {{id name="_Toc28395"/}}**4.1 Device pass-through download (RE)** === |
|
347 |
+=== **4.1 Device pass-through download (RE)** === |
371 |
371 |
|
372 |
372 |
The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet. |
373 |
373 |
|
... |
... |
@@ -385,13 +385,13 @@ |
385 |
385 |
|
386 |
386 |
●Click "Start pass-through" to conduct pass-through according to the specified download tools and selected devices. |
387 |
387 |
|
388 |
|
-● Click [End pass-through] to end pass-through. |
|
365 |
+●Click [End pass-through] to end pass-through. |
389 |
389 |
|
390 |
390 |
⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program. |
391 |
391 |
|
392 |
392 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]] |
393 |
393 |
|
394 |
|
-=== {{id name="_Toc21457"/}}{{id name="_Toc18124"/}}**4.2 Common serial port pass-through (PLC)** === |
|
371 |
+=== **4.2 Common serial port pass-through (PLC)** === |
395 |
395 |
|
396 |
396 |
Based on the normal communication between RE device and PLC or other device, PLC is connected according to the generated virtual serial port, allowing the PLC software on the computer to communicate and connect with the PLC, and completing the functions of uploading/downloading PLC programs and monitoring PLC programs. |
397 |
397 |
|
... |
... |
@@ -415,11 +415,11 @@ |
415 |
415 |
|
416 |
416 |
|
417 |
417 |
|
418 |
|
-{{id name="_Toc14659"/}}{{id name="_Toc5468"/}}{{id name="_Toc29362"/}}⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored. |
|
395 |
+⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored. |
419 |
419 |
|
420 |
420 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]] |
421 |
421 |
|
422 |
|
-{{id name="_Toc24528"/}}{{id name="_Toc6595"/}}{{id name="_Toc20246"/}}**Pass-through Precautions:** |
|
399 |
+**Pass-through Precautions:** |
423 |
423 |
|
424 |
424 |
① In the process of PLC software remote access, the pass-through serial port of the RE device needs to maintain a normal communication state, and the network state needs to remain stable. |
425 |
425 |
|
... |
... |
@@ -429,13 +429,13 @@ |
429 |
429 |
|
430 |
430 |
④ It is necessary to ensure that the PLC serial port of pass-through can support the upload/download function, otherwise the remote pass-through function cannot be realized. |
431 |
431 |
|
432 |
|
-=== {{id name="_Toc21835"/}}**4.3 VPN pass-through (PLC)** === |
|
409 |
+=== **4.3 VPN pass-through (PLC)** === |
433 |
433 |
|
434 |
434 |
**VPN pass-through:** The pass-through function allows the application program on the computer to directly control the PLC device through the RE device, upload/download PLC programs, monitor PLC programs or other configuration information, etc. |
435 |
435 |
|
436 |
436 |
**Steps:** |
437 |
437 |
|
438 |
|
-① Click [VPN pass-through][[image:Wecon V-BOX R Series User Manual 240611 V1.2_74d5c70b.png||height="14" width="15"]] →Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK]. |
|
415 |
+① Click [VPN pass-through] →Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK]. |
439 |
439 |
|
440 |
440 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]] |
441 |
441 |
|
... |
... |
@@ -462,50 +462,3 @@ |
462 |
462 |
The file path is as follows: |
463 |
463 |
|
464 |
464 |
https:~/~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf |
465 |
|
- |
466 |
|
- |
467 |
|
- |
468 |
|
- |
469 |
|
- |
470 |
|
- |
471 |
|
- |
472 |
|
- |
473 |
|
- |
474 |
|
- |
475 |
|
- |
476 |
|
- |
477 |
|
- |
478 |
|
- |
479 |
|
- |
480 |
|
- |
481 |
|
- |
482 |
|
- |
483 |
|
- |
484 |
|
- |
485 |
|
- |
486 |
|
- |
487 |
|
- |
488 |
|
- |
489 |
|
- |
490 |
|
- |
491 |
|
- |
492 |
|
- |
493 |
|
- |
494 |
|
- |
495 |
|
- |
496 |
|
- |
497 |
|
- |
498 |
|
- |
499 |
|
- |
500 |
|
- |
501 |
|
- |
502 |
|
- |
503 |
|
- |
504 |
|
- |
505 |
|
- |
506 |
|
-**Wecon Technology Co., Ltd |
507 |
|
- Factory Address: 10th Building, Area E, Fuzhou Software Park, Gulou District, Fuzhou, Fujian Province, P.R.China |
508 |
|
- R&D Center: Floor 5-7, Block 6, Area F, Fuzhou Software Park, Gulou District, Fuzhou, Fujian, Province, P.R. China |
509 |
|
- Tel: +86-591-87868869 Fax: +86-591-87843899 |
510 |
|
- Website: www.we-con.com.con/en |
511 |
|
- Email: sales@we-con.com.cn** |