@@ -11,7 +11,7 @@ |
11 |
11 |
|
12 |
12 |
=== **1.1 Product appearance** === |
13 |
13 |
|
14 |
|
-==== **(1)RE-00/RE-4G** ==== |
|
14 |
+==== **RE-00/RE-4G** ==== |
15 |
15 |
|
16 |
16 |
[[image:1723447082795-273.png]] |
17 |
17 |
|
... |
... |
@@ -21,7 +21,7 @@ |
21 |
21 |
|
22 |
22 |
RE-00/RE-4G Installation Dimensions |
23 |
23 |
|
24 |
|
-==== **(2) RH-WF** ==== |
|
24 |
+==== **RH-WF** ==== |
25 |
25 |
|
26 |
26 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]] |
27 |
27 |
|
... |
... |
@@ -104,7 +104,7 @@ |
104 |
104 |
=== **1.3 Interface Description** === |
105 |
105 |
))) |
106 |
106 |
|
107 |
|
-==== **(1) Appearance component description** ==== |
|
107 |
+==== **Appearance component description** ==== |
108 |
108 |
|
109 |
109 |
**RE-00/RE-4G** |
110 |
110 |
|
... |
... |
@@ -116,7 +116,7 @@ |
116 |
116 |
|**1**|Indicator lamp|**2**|Micro-USB|**3**|Ethernet port|**4**|COM port |
117 |
117 |
|**5**|Power supply|**6**|4G antenna (Optional)|**7**|Fixed fastener|**8**|SIM card (Optional) |
118 |
118 |
|
119 |
|
-**RH-WF** |
|
119 |
+**RH-WF** |
120 |
120 |
|
121 |
121 |
[[image:1723448356737-113.png]] |
122 |
122 |
|
... |
... |
@@ -126,9 +126,9 @@ |
126 |
126 |
|**5**|HDMI|**6**|TYPE-C|**7**|COM port|**8**|I/O interface and RS485 terminal |
127 |
127 |
|**9**|Power supply|**10**|WIFI antenna|**11**|Fixed fastener| | |
128 |
128 |
|
129 |
|
-==== **(2) Interface Description** ==== |
|
129 |
+==== **Interface Description** ==== |
130 |
130 |
|
131 |
|
-**RE-00/RE-4G** |
|
131 |
+**RE-00/RE-4G** |
132 |
132 |
|
133 |
133 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d215ad34.png||height="276" width="616"]] |
134 |
134 |
|
... |
... |
@@ -135,11 +135,11 @@ |
135 |
135 |
|
136 |
136 |
**RH-WF** |
137 |
137 |
|
138 |
|
-[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]] |
|
138 |
+[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]] |
139 |
139 |
|
140 |
|
-==== **(3) Interface Definition** ==== |
|
140 |
+==== **Interface Definition** ==== |
141 |
141 |
|
142 |
|
-**RE-00/RE-4G COM1 interface definition** |
|
142 |
+**RE-00/RE-4G COM1 interface definition** |
143 |
143 |
|
144 |
144 |
|**Pin**|**Definition**|**Pin**|**Definition** |
145 |
145 |
|1|RS422 TX+/RS485 A+|2|RS232 RXD |
... |
... |
@@ -147,7 +147,7 @@ |
147 |
147 |
|6|RS422 TX-/RS485 B-|8|RS422 RX- |
148 |
148 |
|9|RS422 RX+| | |
149 |
149 |
|
150 |
|
-**RH-WF** |
|
150 |
+**RH-WF** |
151 |
151 |
|
152 |
152 |
|(% colspan="2" %)**Pin**|**Definition** |
153 |
153 |
|(% rowspan="7" %)[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ef6a7104.gif||height="205" width="93"]]|S/S|((( |
... |
... |
@@ -308,12 +308,12 @@ |
308 |
308 |
|
309 |
309 |
②Use manual positioning. |
310 |
310 |
|
311 |
|
-Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync. |
|
311 |
+**Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.** |
312 |
312 |
|
313 |
313 |
|
314 |
|
-== {{id name="_Toc7609"/}}{{id name="_Toc19227"/}}**3 Pass-through of device** == |
|
314 |
+== **4 Pass-through of device** == |
315 |
315 |
|
316 |
|
-{{id name="_Toc16958"/}}{{id name="_Toc18341"/}}{{id name="_Toc10036"/}}{{id name="_Toc14306"/}}{{id name="_Toc8318"/}}{{id name="_Toc23343"/}}{{id name="_Toc11131"/}}{{id name="_Toc21238"/}}{{id name="_Toc23066"/}}{{id name="_Toc22286"/}}{{id name="_Toc32206"/}}{{id name="_Toc14201"/}}{{id name="_Toc5622"/}}{{id name="_Toc10379"/}}{{id name="_Toc29542"/}}{{id name="_Toc3580"/}}{{id name="_Toc20482"/}}{{id name="_Toc22905"/}}{{id name="_Toc10700"/}}{{id name="_Toc2060"/}}{{id name="_Toc10051"/}}**Note: The pass-through operation steps of V-NET/V-IEC are for reference only.** |
|
316 |
+**Note: The pass-through operation steps of V-NET/V-IEC are for reference only.** |
317 |
317 |
|
318 |
318 |
Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc. |
319 |
319 |
|
... |
... |
@@ -321,15 +321,15 @@ |
321 |
321 |
|
322 |
322 |
Device status description table is as follows: |
323 |
323 |
|
324 |
|
-|**Color**|**Color Value (HEX)**|**Status**|**Description** |
325 |
|
-|●|#18E600|Online|Pass-through available |
326 |
|
-|●|#B5C1D8|Offline|Pass-through is not allowed |
327 |
|
-|●|#1C9BFD|Pass-through connecting|In pass-through |
328 |
|
-|●|#005CFF|VPN connecting|In pass-through |
329 |
|
-|●|#FD8B09|VPN pass-through is reconnecting|Pass-through reconnecting due to network and other reasons |
330 |
|
-|●|#2C405E|VPN pass-through is ending|The end of pass-through due to [End pass-through] |
331 |
|
-|●|#109A00|Download is ready.|Download channel is ready. (Download can be executed.) |
332 |
|
-|●|#009577|Download|In download |
|
324 |
+|(% style="width:82px" %)**Color**|(% style="width:248px" %)**Color Value (HEX)**|**Status**|**Description** |
|
325 |
+|(% style="width:82px" %)[[image:1723449592784-532.png]]|(% style="width:248px" %)#18E600|Online|Pass-through available |
|
326 |
+|(% style="width:82px" %)[[image:1723449624928-809.png]]|(% style="width:248px" %)#B5C1D8|Offline|Pass-through is not allowed |
|
327 |
+|(% style="width:82px" %)[[image:1723449706265-533.png]]|(% style="width:248px" %)#1C9BFD|Pass-through connecting|In pass-through |
|
328 |
+|(% style="width:82px" %)[[image:1723449737329-134.png||height="28" width="31"]]|(% style="width:248px" %)#005CFF|VPN connecting|In pass-through |
|
329 |
+|(% style="width:82px" %)[[image:1723449765210-888.png]]|(% style="width:248px" %)#FD8B09|VPN pass-through is reconnecting|Pass-through reconnecting due to network and other reasons |
|
330 |
+|(% style="width:82px" %)[[image:1723449785743-305.png||height="28" width="32"]]|(% style="width:248px" %)#2C405E|VPN pass-through is ending|The end of pass-through due to [End pass-through] |
|
331 |
+|(% style="width:82px" %)[[image:1723449827434-119.png]]|(% style="width:248px" %)#109A00|Download is ready.|Download channel is ready. (Download can be executed.) |
|
332 |
+|(% style="width:82px" %)[[image:1723449809049-353.png]]|(% style="width:248px" %)#009577|Download|In download |
333 |
333 |
|
334 |
334 |
**Pass-through precautions:** |
335 |
335 |
|
... |
... |
@@ -344,7 +344,7 @@ |
344 |
344 |
● When the current user has a device in pass-through, “Start pass-through” cannot be clicked. |
345 |
345 |
|
346 |
346 |
|
347 |
|
-=== {{id name="_Toc28395"/}}**4.1 Device pass-through download (RE)** === |
|
347 |
+=== **4.1 Device pass-through download (RE)** === |
348 |
348 |
|
349 |
349 |
The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet. |
350 |
350 |
|
... |
... |
@@ -362,7 +362,7 @@ |
362 |
362 |
|
363 |
363 |
●Click "Start pass-through" to conduct pass-through according to the specified download tools and selected devices. |
364 |
364 |
|
365 |
|
-● Click [End pass-through] to end pass-through. |
|
365 |
+●Click [End pass-through] to end pass-through. |
366 |
366 |
|
367 |
367 |
⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program. |
368 |
368 |
|
... |
... |
@@ -392,11 +392,11 @@ |
392 |
392 |
|
393 |
393 |
|
394 |
394 |
|
395 |
|
-{{id name="_Toc14659"/}}{{id name="_Toc5468"/}}{{id name="_Toc29362"/}}⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored. |
|
395 |
+⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored. |
396 |
396 |
|
397 |
397 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]] |
398 |
398 |
|
399 |
|
-{{id name="_Toc24528"/}}{{id name="_Toc6595"/}}{{id name="_Toc20246"/}}**Pass-through Precautions:** |
|
399 |
+**Pass-through Precautions:** |
400 |
400 |
|
401 |
401 |
① In the process of PLC software remote access, the pass-through serial port of the RE device needs to maintain a normal communication state, and the network state needs to remain stable. |
402 |
402 |
|
... |
... |
@@ -412,7 +412,7 @@ |
412 |
412 |
|
413 |
413 |
**Steps:** |
414 |
414 |
|
415 |
|
-① Click [VPN pass-through] →Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK]. |
|
415 |
+① Click [VPN pass-through] [[image:1723450415577-521.png]]→Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK]. |
416 |
416 |
|
417 |
417 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]] |
418 |
418 |
|
... |
... |
@@ -438,4 +438,95 @@ |
438 |
438 |
|
439 |
439 |
The file path is as follows: |
440 |
440 |
|
441 |
|
-https:~/~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf |
|
441 |
+[[https:~~/~~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf>>https://www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf]] |
|
442 |
+ |
|
443 |
+== 5 Resumable upload == |
|
444 |
+ |
|
445 |
+3000ig/8000ig HMI and RE/RH,E/H V-BOX can support a function for resumable upload. The function is to save lost data when the device is offline and upload lost data to Cloud when the device is online again. |
|
446 |
+ |
|
447 |
+The following table shows the maximum number of the resumable data and the biggest file size of the resumable data: |
|
448 |
+ |
|
449 |
+|= |=RE/RH|=3000ig/8000ig HMI|=E/H V-BOX |
|
450 |
+|=data|100,000|100,000|2,000 |
|
451 |
+|=file size|2M|2M|N/A |
|
452 |
+ |
|
453 |
+(% class="box infomessage" %) |
|
454 |
+((( |
|
455 |
+Note: |
|
456 |
+ |
|
457 |
+1.The function don't configure by manual. |
|
458 |
+ |
|
459 |
+2.When the device is online again, There is a keep-alive interval for about 30s. So data will be lost during the time. |
|
460 |
+))) |
|
461 |
+ |
|
462 |
+== 6 Remote Background == |
|
463 |
+ |
|
464 |
+R series box doesn’t have the actual screen, so a new remote page is designed for background setting if user want to change some background parameters. |
|
465 |
+ |
|
466 |
+(% class="box infomessage" %) |
|
467 |
+((( |
|
468 |
+Note: HMI of V3.0 version also supports this function. |
|
469 |
+))) |
|
470 |
+ |
|
471 |
+=== Enter remote background === |
|
472 |
+ |
|
473 |
+ |
|
474 |
+Keep R series/HMI and pc in the same Lan. Input "IP:9091" in pc webpage. |
|
475 |
+ |
|
476 |
+(% style="text-align:center" %) |
|
477 |
+[[image:TYyajNRreA.png]] |
|
478 |
+ |
|
479 |
+There will be a User login screen and input Account and Password. |
|
480 |
+ |
|
481 |
+(% style="text-align:center" %) |
|
482 |
+[[image:zt10uj9hHA.png]] |
|
483 |
+ |
|
484 |
+(% class="box infomessage" %) |
|
485 |
+((( |
|
486 |
+Note: The default Account is "admin". The default Password is "888888". |
|
487 |
+))) |
|
488 |
+ |
|
489 |
+=== Modify account and password === |
|
490 |
+ |
|
491 |
+Project Settings → Security→ LAN Monitoring Security→ OK → Compile and Download the project |
|
492 |
+ |
|
493 |
+(% style="text-align:center" %) |
|
494 |
+[[image:rDTHQo0uzs.png]] |
|
495 |
+ |
|
496 |
+== 7 Centralized Monitor == |
|
497 |
+ |
|
498 |
+In HMI V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs and PC are in the same LAN, they can be selected for centralized monitor. |
|
499 |
+ |
|
500 |
+(% class="box infomessage" %) |
|
501 |
+((( |
|
502 |
+Note: Centralized Monitor can not be accomplished by connection that HMIs are connected to PC with USB. |
|
503 |
+))) |
|
504 |
+ |
|
505 |
+=== Local Device === |
|
506 |
+ |
|
507 |
+Download → choose monitored HMIs |
|
508 |
+ |
|
509 |
+(% style="text-align:center" %) |
|
510 |
+[[image:1yeIHMWarO.png]] |
|
511 |
+ |
|
512 |
+=== Cloud Device === |
|
513 |
+ |
|
514 |
+Cloud Linker →log in → select the server in configuration→ log in V-net Client account |
|
515 |
+ |
|
516 |
+(% style="text-align:center" %) |
|
517 |
+[[image:DTQ10E5Cv6.png]] |
|
518 |
+ |
|
519 |
+(% style="text-align:center" %) |
|
520 |
+[[image:IPJDUDCzD4.png]] |
|
521 |
+ |
|
522 |
+After logging in the account, select monitored HMIs. |
|
523 |
+ |
|
524 |
+(% style="text-align:center" %) |
|
525 |
+[[image:y6AlyJtG24.png]] |
|
526 |
+ |
|
527 |
+In Centralized monitor screen, selected HMI project will be display here. What's more, these projects can be operated in the screen. |
|
528 |
+ |
|
529 |
+(% style="text-align:center" %) |
|
530 |
+[[image:MnqsQgF2Cm.png]] |
|
531 |
+ |
|
532 |
+ |