... |
... |
@@ -11,7 +11,7 @@ |
11 |
11 |
|
12 |
12 |
=== **1.1 Product appearance** === |
13 |
13 |
|
14 |
|
-==== **(1)RE-00/RE-4G** ==== |
|
14 |
+==== **RE-00/RE-4G** ==== |
15 |
15 |
|
16 |
16 |
[[image:1723447082795-273.png]] |
17 |
17 |
|
... |
... |
@@ -21,7 +21,7 @@ |
21 |
21 |
|
22 |
22 |
RE-00/RE-4G Installation Dimensions |
23 |
23 |
|
24 |
|
-==== **(2) RH-WF** ==== |
|
24 |
+==== **RH-WF** ==== |
25 |
25 |
|
26 |
26 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]] |
27 |
27 |
|
... |
... |
@@ -166,6 +166,8 @@ |
166 |
166 |
|
167 |
167 |
== **2 Applications** == |
168 |
168 |
|
|
169 |
+=== Basic application === |
|
170 |
+ |
169 |
169 |
R series products, which can easily realize advanced requirements such as real-time display on industrial sites. |
170 |
170 |
|
171 |
171 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]] |
... |
... |
@@ -176,6 +176,11 @@ |
176 |
176 |
|
177 |
177 |
③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software. |
178 |
178 |
|
|
181 |
+ |
|
182 |
+=== RH-WF and WS21 === |
|
183 |
+ |
|
184 |
+RH-WF supports local HDMI interface to connect to in-site screen like a TV screen to display the project. WS21, a touching screen, can be |
|
185 |
+ |
179 |
179 |
== **3 Operation Instructions** == |
180 |
180 |
|
181 |
181 |
=== **3.1 Project Download-PIStudio** === |
... |
... |
@@ -311,7 +311,7 @@ |
311 |
311 |
**Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.** |
312 |
312 |
|
313 |
313 |
|
314 |
|
-== **3 Pass-through of device** == |
|
321 |
+== **4 Pass-through of device** == |
315 |
315 |
|
316 |
316 |
**Note: The pass-through operation steps of V-NET/V-IEC are for reference only.** |
317 |
317 |
|
... |
... |
@@ -440,9 +440,8 @@ |
440 |
440 |
|
441 |
441 |
[[https:~~/~~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf>>https://www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf]] |
442 |
442 |
|
|
450 |
+== 5 Resumable upload == |
443 |
443 |
|
444 |
|
-= Resumable upload = |
445 |
|
- |
446 |
446 |
3000ig/8000ig HMI and RE/RH,E/H V-BOX can support a function for resumable upload. The function is to save lost data when the device is offline and upload lost data to Cloud when the device is online again. |
447 |
447 |
|
448 |
448 |
The following table shows the maximum number of the resumable data and the biggest file size of the resumable data: |
... |
... |
@@ -453,9 +453,81 @@ |
453 |
453 |
|
454 |
454 |
(% class="box infomessage" %) |
455 |
455 |
((( |
456 |
|
-Note:1.The function don't configure by manual. |
|
462 |
+Note: |
457 |
457 |
|
|
464 |
+1.The function don't configure by manual. |
|
465 |
+ |
458 |
458 |
2.When the device is online again, There is a keep-alive interval for about 30s. So data will be lost during the time. |
459 |
459 |
))) |
460 |
460 |
|
|
469 |
+== 6 Remote Background == |
|
470 |
+ |
|
471 |
+R series box doesn’t have the actual screen, so a new remote page is designed for background setting if user want to change some background parameters. |
|
472 |
+ |
|
473 |
+(% class="box infomessage" %) |
|
474 |
+((( |
|
475 |
+Note: HMI of V3.0 version also supports this function. |
|
476 |
+))) |
|
477 |
+ |
|
478 |
+=== Enter remote background === |
|
479 |
+ |
|
480 |
+ |
|
481 |
+Keep R series/HMI and pc in the same Lan. Input "IP:9091" in pc webpage. |
|
482 |
+ |
|
483 |
+(% style="text-align:center" %) |
|
484 |
+[[image:TYyajNRreA.png]] |
|
485 |
+ |
|
486 |
+There will be a User login screen and input Account and Password. |
|
487 |
+ |
|
488 |
+(% style="text-align:center" %) |
|
489 |
+[[image:zt10uj9hHA.png]] |
|
490 |
+ |
|
491 |
+(% class="box infomessage" %) |
|
492 |
+((( |
|
493 |
+Note: The default Account is "admin". The default Password is "888888". |
|
494 |
+))) |
|
495 |
+ |
|
496 |
+=== Modify account and password === |
|
497 |
+ |
|
498 |
+Project Settings → Security→ LAN Monitoring Security→ OK → Compile and Download the project |
|
499 |
+ |
|
500 |
+(% style="text-align:center" %) |
|
501 |
+[[image:rDTHQo0uzs.png]] |
|
502 |
+ |
|
503 |
+== 7 Centralized Monitor == |
|
504 |
+ |
|
505 |
+In HMI V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs and PC are in the same LAN, they can be selected for centralized monitor. |
|
506 |
+ |
|
507 |
+(% class="box infomessage" %) |
|
508 |
+((( |
|
509 |
+Note: Centralized Monitor can not be accomplished by connection that HMIs are connected to PC with USB. |
|
510 |
+))) |
|
511 |
+ |
|
512 |
+=== Local Device === |
|
513 |
+ |
|
514 |
+Download → choose monitored HMIs |
|
515 |
+ |
|
516 |
+(% style="text-align:center" %) |
|
517 |
+[[image:1yeIHMWarO.png]] |
|
518 |
+ |
|
519 |
+=== Cloud Device === |
|
520 |
+ |
|
521 |
+Cloud Linker →log in → select the server in configuration→ log in V-net Client account |
|
522 |
+ |
|
523 |
+(% style="text-align:center" %) |
|
524 |
+[[image:DTQ10E5Cv6.png]] |
|
525 |
+ |
|
526 |
+(% style="text-align:center" %) |
|
527 |
+[[image:IPJDUDCzD4.png]] |
|
528 |
+ |
|
529 |
+After logging in the account, select monitored HMIs. |
|
530 |
+ |
|
531 |
+(% style="text-align:center" %) |
|
532 |
+[[image:y6AlyJtG24.png]] |
|
533 |
+ |
|
534 |
+In Centralized monitor screen, selected HMI project will be display here. What's more, these projects can be operated in the screen. |
|
535 |
+ |
|
536 |
+(% style="text-align:center" %) |
|
537 |
+[[image:MnqsQgF2Cm.png]] |
|
538 |
+ |
461 |
461 |
|