Changes for page R Series

Last modified by Mora Zhou on 2024/12/05 14:34

From version 51.1
edited by Joe
on 2024/11/11 09:28
Change comment: There is no comment for this version
To version 67.1
edited by Mora Zhou
on 2024/12/05 14:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.Mora
Content
... ... @@ -1,4 +1,4 @@
1 -== **1 Product description** ==
1 +== **Product description** ==
2 2  
3 3  |**Series**|(% style="width:132px" %)**Model**|(% style="width:552px" %)**Description**
4 4  |(% rowspan="3" %)**R Series**|(% style="width:132px" %)RE-00|(% style="width:552px" %)1 network port, single serial port
... ... @@ -9,14 +9,16 @@
9 9  2 optocoupler isolated input (DI), 2 relay output (DO)
10 10  )))
11 11  
12 -=== **1.1 Product appearance** ===
12 +=== **Product appearance** ===
13 13  
14 14  ==== **RE-00/RE-4G** ====
15 15  
16 +(% style="text-align:center" %)
16 16  [[image:1723447082795-273.png]]
17 17  
18 18  RE-00/RE-4G Appearance
19 19  
21 +(% style="text-align:center" %)
20 20  [[image:1723447096815-592.png]]
21 21  
22 22  RE-00/RE-4G Installation Dimensions
... ... @@ -23,6 +23,7 @@
23 23  
24 24  ==== **RH-WF** ====
25 25  
28 +(% style="text-align:center" %)
26 26  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]]
27 27  
28 28  (((
... ... @@ -31,15 +31,16 @@
31 31  
32 32  RH-WF
33 33  
37 +(% style="text-align:center" %)
34 34  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]]
35 35  
36 36  Installation size
37 37  
38 38  
39 -=== **1.2 Product specifications** ===
43 +=== **Product specifications** ===
40 40  
41 41  (((
42 -(% style="width:815px" %)
46 +(% style="width:1075px" %)
43 43  |=(% colspan="3" %)**Model/Specifications**|=**RE-00**|=**RE-4G**|=**RH-WF**
44 44  |(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters**
45 45  |(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz
... ... @@ -84,7 +84,7 @@
84 84  |(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation)
85 85  |(% colspan="3" %)CE certification|(% colspan="3" %)Yes
86 86  |(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification
87 -|(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A
91 +|(% colspan="3" style="width:401px" %)Positioning function|(% colspan="2" style="width:401px" %)N/A  /  Base station positioning|(% style="width:401px" %)N/A
88 88  |(% rowspan="7" %)(((
89 89  Software
90 90  
... ... @@ -101,7 +101,7 @@
101 101  |(% colspan="2" %)VPN Pass trough|(% colspan="3" %)Yes
102 102  |(% colspan="2" %)API interface|(% colspan="3" %)Yes
103 103  
104 -=== **1.3 Interface Description** ===
108 +=== **Interface Description** ===
105 105  )))
106 106  
107 107  ==== **Appearance component description** ====
... ... @@ -108,6 +108,7 @@
108 108  
109 109  **RE-00/RE-4G**
110 110  
115 +(% style="text-align:center" %)
111 111  [[image:1723448311561-814.png]]
112 112  
113 113  RE-00/RE-4G Component Description
... ... @@ -118,6 +118,7 @@
118 118  
119 119  **RH-WF**
120 120  
126 +(% style="text-align:center" %)
121 121  [[image:1723448356737-113.png]]
122 122  
123 123  RH-WF Component Description
... ... @@ -130,12 +130,14 @@
130 130  
131 131  **RE-00/RE-4G**
132 132  
139 +(% style="text-align:center" %)
133 133  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d215ad34.png||height="276" width="616"]]
134 134  
135 135  
136 136  **RH-WF**
137 137  
138 -[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]]
145 +(% style="text-align:center" %)
146 +[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png]]
139 139  
140 140  ==== **Interface Definition** ====
141 141  
... ... @@ -164,10 +164,13 @@
164 164  |485-|RS485-
165 165  |GND|Ground
166 166  
167 -== **2 Applications** ==
175 +== **Applications** ==
168 168  
177 +=== Basic application ===
178 +
169 169  R series products, which can easily realize advanced requirements such as real-time display on industrial sites.
170 170  
181 +(% style="text-align:center" %)
171 171  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]]
172 172  
173 173  ① Large-screen display, connect computer/TV Display the project screen;
... ... @@ -176,14 +176,32 @@
176 176  
177 177  ③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software.
178 178  
179 -== **3 Operation Instructions** ==
180 180  
181 -=== **3.1 Project Download-PIStudio** ===
191 +=== RH-WF and WS21 ===
182 182  
193 +RH-WF supports local HDMI interface to connect to in-site screen like a TV screen to display the project. WS21, a touching screen, can be connected with RH-WF via HDMI interface. The project an be operated manually in WS21 screen.
194 +
195 +(% style="text-align:center" %)
196 +[[image:图片1.png]]
197 +
198 +(% style="text-align:center" %)
199 +[[image:图片2.png]]
200 +
201 +HDMI Port is for displaying the project. And USB Port is for touching.
202 +
203 +[[WS21 parameter>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/Wecon%20WS21%20Monitor.pdf]]
204 +
205 +[[Demo video>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/RH1.mp4]]
206 +
207 +== **Operation Instructions** ==
208 +
209 +=== **Project Download-PIStudio** ===
210 +
183 183  **(1) New project**
184 184  
185 185  PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
186 186  
215 +(% style="text-align:center" %)
187 187  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8971673d.png||height="340" width="638"]]
188 188  
189 189  **(2) Enable cloud server**
... ... @@ -195,6 +195,7 @@
195 195  Upload to the cloud: All configured tag information, historical information, and alarm information will be pushed to V-NET.
196 196  
197 197  
227 +(% style="text-align:center" %)
198 198  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_19762229.png||height="360" width="638"]]
199 199  
200 200  **(3) Project compile/download**
... ... @@ -201,15 +201,17 @@
201 201  
202 202  After the project is completed, click **[Project Compile]**→After prompting that the compilation is completed, click** [Download Project]**→device detected, **[PC port]**. Ethernet or USB download→[PC→HMI]→pop up a prompt, click **[OK]** → complete the configuration project download, it will take effect after restart.
203 203  
234 +(% style="text-align:center" %)
204 204  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_38834748.png||height="340" width="634"]]
205 205  
237 +(% style="text-align:center" %)
206 206  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_31fafd4e.png||height="287" width="348"]]
207 207  
208 208  **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
209 209  
210 -=== **3.2 Check V-NET IoT System** ===
242 +=== **Check V-NET IoT System** ===
211 211  
212 -==== **3.2.1 V-NET login** ====
244 +==== **V-NET login** ====
213 213  
214 214  (1) New users must register first, and after the registration is successful, the user can use it.
215 215  
... ... @@ -217,6 +217,7 @@
217 217  
218 218  ● Users need to remember the registered account and password, and can log in simultaneously on the PC/APP.
219 219  
252 +(% style="text-align:center" %)
220 220  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_7103ee91.png||height="274" width="453"]]
221 221  
222 222  (2) Enter the account and password, and then click the **[Log in] **button.
... ... @@ -223,12 +223,14 @@
223 223  
224 224  (3) After admin account logs in to the platform, it will jump to the homepage by default, as shown in the figure below.
225 225  
259 +(% style="text-align:center" %)
226 226  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
227 227  
228 -==== **3.2.2 Adding devices** ====
262 +==== **Adding devices** ====
229 229  
230 230  (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
231 231  
266 +(% style="text-align:center" %)
232 232  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_45c9855a.png||height="409" width="638"]]
233 233  
234 234  (2) After the **[Add Device]** window pops up, enter the device machine code and password, etc., and add the device. Other instructions are as follows:   
... ... @@ -247,12 +247,13 @@
247 247  
248 248   (3) Binding device is successful, click OK, prompt: Bind device successful!
249 249  
250 -==== **3.2.3 V-NET check** ====
285 +==== **V-NET check** ====
251 251  
252 252  **(1) Remote monitoring**
253 253  
254 254  The remote monitoring module can display the current screen in real time, and realize the operation of the project on the web page, realize the remote monitoring of the device and the control of the screen.
255 255  
291 +(% style="text-align:center" %)
256 256  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a262a004.png||height="362" width="638"]]
257 257  
258 258  **(2) Data viewing**
... ... @@ -259,6 +259,7 @@
259 259  
260 260  Data view has six modules, including Communication port, Collection point, Alarm configuration, Alarm record, Historical configuration, Historical data record.
261 261  
298 +(% style="text-align:center" %)
262 262  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_6ce8af63.png||height="357" width="638"]]
263 263  
264 264  **The specific parameter is as follows:**
... ... @@ -275,6 +275,7 @@
275 275  
276 276  The cloud SCADA platform is mainly used to display the monitoring/operation interface of the bound device in the V-NET.
277 277  
315 +(% style="text-align:center" %)
278 278  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8ecdd915.png||height="332" width="638"]]
279 279  
280 280   The main functions of Cloud SCADA interface in device management are as follows:
... ... @@ -292,6 +292,7 @@
292 292  
293 293  Include: "Basic information, status push, register information, version information" for the device.
294 294  
333 +(% style="text-align:center" %)
295 295  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_b1d4b150.png||height="330" width="638"]]
296 296  
297 297  ●**Device name:** Mainly used to distinguish various devices.
... ... @@ -310,13 +310,13 @@
310 310  
311 311  **Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.**
312 312  
352 +== **Pass-through of device** ==
313 313  
314 -== **4 Pass-through of device** ==
315 -
316 316  **Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
317 317  
318 318  Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc.
319 319  
358 +(% style="text-align:center" %)
320 320  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1c4453d8.png||height="338" width="638"]]
321 321  
322 322  Device status description table is as follows:
... ... @@ -344,7 +344,7 @@
344 344  ● When the current user has a device in pass-through, “Start pass-through” cannot be clicked.
345 345  
346 346  
347 -=== **4.1 Device pass-through download (RE)** ===
386 +=== **Device pass-through download (RE)** ===
348 348  
349 349  The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet.
350 350  
... ... @@ -366,9 +366,10 @@
366 366  
367 367  ⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program.
368 368  
408 +(% style="text-align:center" %)
369 369  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
370 370  
371 -=== **4.2 Common serial port pass-through (PLC)** ===
411 +=== **Common serial port pass-through (PLC)** ===
372 372  
373 373  Based on the normal communication between RE device and PLC or other device, PLC is connected according to the generated virtual serial port, allowing the PLC software on the computer to communicate and connect with the PLC, and completing the functions of uploading/downloading PLC programs and monitoring PLC programs.
374 374  
... ... @@ -376,14 +376,17 @@
376 376  
377 377  ① Virtual serial port settings: Click** [Settings]** →**[Virtual Serial Port]**→**[Enable Virtual Serial Port] **→**[Select Serial Port]**. Pay attention to the serial port, please do not reuse it. (When the COM port is changed, if a PLC or other software is connecting to the original COM port, it will be disconnected.)
378 378  
419 +(% style="text-align:center" %)
379 379  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_54a850e2.png||height="136" width="639"]]
380 380  
381 381  ② Remote download configuration: Click [PLC pass-through ][[image:Wecon V-BOX R Series User Manual 240611 V1.2_cfc415e2.png||height="14" width="15"]] →Select the device that requires pass-through→[New/Edit]→[New Template] Configure pass-through parameters: [Name], [Communication Port], [Connection Method], [Baud Rate], [Stop Bit], [Data Bit], [Check Bit], the configured parameters need to be consistent with the PLC serial port parameters →[OK]→Prompt "Add successfully!"→[OK].
382 382  
424 +(% style="text-align:center" %)
383 383  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_353545eb.png||height="339" width="638"]]
384 384  
385 385  ③ Pass-through steps: On the pass-through interface, click [Start pass-through]→after successful pass-through, it will prompt "pass-through succeeded"→[OK].
386 386  
429 +(% style="text-align:center" %)
387 387  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_5b5ad7dd.png||height="339" width="638"]]
388 388  
389 389  ④ After the pass-through is successful, the indicator light of the corresponding RE device on the PC will turn blue, and the [current status] will become pass-through, indicating that the device is in the "pass-through" status.
... ... @@ -394,6 +394,7 @@
394 394  
395 395  ⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored.
396 396  
440 +(% style="text-align:center" %)
397 397  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]]
398 398  
399 399  **Pass-through Precautions:**
... ... @@ -406,7 +406,7 @@
406 406  
407 407  ④ It is necessary to ensure that the PLC serial port of pass-through can support the upload/download function, otherwise the remote pass-through function cannot be realized.
408 408  
409 -=== **4.3 VPN pass-through (PLC)** ===
453 +=== **VPN pass-through (PLC)** ===
410 410  
411 411  **VPN pass-through:** The pass-through function allows the application program on the computer to directly control the PLC device through the RE device, upload/download PLC programs, monitor PLC programs or other configuration information, etc.
412 412  
... ... @@ -414,16 +414,19 @@
414 414  
415 415  ① Click [VPN pass-through] [[image:1723450415577-521.png]]→Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK].
416 416  
417 -[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]]
461 +(% style="text-align:center" %)
462 +[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png]]
418 418  
419 419  ② After pass-through is successful, the indicator light of the corresponding RE device on the PC will turn yellow, and [current status] will become in the VPN pass-through, indicating that the device is in the "pass-through" status. (**Note:** You cannot click [End pass-through], otherwise you will exit the pass-through.)
420 420  
421 421  ③ After the pass-through is successful, a virtual network card will be generated. You can check whether the IP is generated through the network card of the computer, as shown below.
422 422  
468 +(% style="text-align:center" %)
423 423  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a53a8121.png||height="336" width="638"]]
424 424  
425 425  ④ When PLC software completes the remote operation, select [End pass-through]→Prompt "End VPN pass through successfully"→[OK], at this time the device will automatically restart, and after the restart is completed, the working status before pass-through will be restored.
426 426  
473 +(% style="text-align:center" %)
427 427  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_40416c98.png||height="336" width="638"]]
428 428  
429 429  **Pass-through precautions:**
... ... @@ -440,7 +440,7 @@
440 440  
441 441  [[https:~~/~~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf>>https://www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf]]
442 442  
443 -== 5 Resumable upload ==
490 +== Resumable upload ==
444 444  
445 445  3000ig/8000ig HMI and RE/RH,E/H V-BOX can support  a function for resumable upload. The function is to save lost data when the device is offline and upload lost data to Cloud when the device is online again.
446 446  
... ... @@ -459,4 +459,74 @@
459 459  2.When the device is online again, There is a keep-alive interval for about 30s. So data will be lost during the time.
460 460  )))
461 461  
509 +== Remote Background ==
510 +
511 +R series box doesn’t have the actual screen, so a new remote page is designed for background setting if user want to change some background parameters.
512 +
513 +(% class="box infomessage" %)
514 +(((
515 +Note: HMI of V3.0 version also supports this function.
516 +)))
517 +
518 +=== Enter remote background ===
519 +
520 +
521 +Keep R series/HMI and pc in the same Lan. Input "IP:9091" in pc webpage.
522 +
523 +(% style="text-align:center" %)
524 +[[image:TYyajNRreA.png]]
525 +
526 +There will be a User login screen and input Account and Password.
527 +
528 +(% style="text-align:center" %)
529 +[[image:zt10uj9hHA.png]]
530 +
531 +(% class="box infomessage" %)
532 +(((
533 +Note: The default Account is "admin". The default Password is "888888".
534 +)))
535 +
536 +=== Modify account and password ===
537 +
538 +Project Settings → Security→ LAN Monitoring Security→ OK → Compile and Download the project
539 +
540 +(% style="text-align:center" %)
541 +[[image:rDTHQo0uzs.png]]
542 +
543 +== Centralized Monitor ==
544 +
545 +In HMI V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs and PC are in the same LAN, they can be selected for centralized monitor.
546 +
547 +(% class="box infomessage" %)
548 +(((
549 +Note: Centralized Monitor can not be accomplished by connection that HMIs are connected to PC with USB.
550 +)))
551 +
552 +=== Local Device ===
553 +
554 +Download → choose monitored HMIs
555 +
556 +(% style="text-align:center" %)
557 +[[image:1yeIHMWarO.png]]
558 +
559 +=== Cloud Device ===
560 +
561 +Cloud Linker →log in → select the server in configuration→ log in V-net Client account
562 +
563 +(% style="text-align:center" %)
564 +[[image:DTQ10E5Cv6.png]]
565 +
566 +(% style="text-align:center" %)
567 +[[image:IPJDUDCzD4.png]]
568 +
569 +After logging in the account, select monitored HMIs.
570 +
571 +(% style="text-align:center" %)
572 +[[image:y6AlyJtG24.png]]
573 +
574 +In Centralized monitor screen, selected HMI project will be display here. What's more, these projects can be operated in the screen.
575 +
576 +(% style="text-align:center" %)
577 +[[image:MnqsQgF2Cm.png]]
578 +
462 462  
1yeIHMWarO.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +474.8 KB
Content
DTQ10E5Cv6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +43.1 KB
Content
IPJDUDCzD4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +39.3 KB
Content
MnqsQgF2Cm.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +534.4 KB
Content
TYyajNRreA.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +2.8 KB
Content
cDi9ww3lYF.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +39.4 KB
Content
j08osLJZR0.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +88.9 KB
Content
rDTHQo0uzs.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +88.7 KB
Content
sNMHaXOG0U.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +40.6 KB
Content
y6AlyJtG24.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +32.5 KB
Content
zt10uj9hHA.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +229.6 KB
Content
图片1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +213.8 KB
Content
图片2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +117.2 KB
Content