@@ -13,10 +13,12 @@ |
13 |
13 |
|
14 |
14 |
==== **RE-00/RE-4G** ==== |
15 |
15 |
|
|
16 |
+(% style="text-align:center" %) |
16 |
16 |
[[image:1723447082795-273.png]] |
17 |
17 |
|
18 |
18 |
RE-00/RE-4G Appearance |
19 |
19 |
|
|
21 |
+(% style="text-align:center" %) |
20 |
20 |
[[image:1723447096815-592.png]] |
21 |
21 |
|
22 |
22 |
RE-00/RE-4G Installation Dimensions |
... |
... |
@@ -23,6 +23,7 @@ |
23 |
23 |
|
24 |
24 |
==== **RH-WF** ==== |
25 |
25 |
|
|
28 |
+(% style="text-align:center" %) |
26 |
26 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]] |
27 |
27 |
|
28 |
28 |
((( |
... |
... |
@@ -31,6 +31,7 @@ |
31 |
31 |
|
32 |
32 |
RH-WF |
33 |
33 |
|
|
37 |
+(% style="text-align:center" %) |
34 |
34 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]] |
35 |
35 |
|
36 |
36 |
Installation size |
... |
... |
@@ -39,7 +39,7 @@ |
39 |
39 |
=== **1.2 Product specifications** === |
40 |
40 |
|
41 |
41 |
((( |
42 |
|
-(% style="width:815px" %) |
|
46 |
+(% style="width:1075px" %) |
43 |
43 |
|=(% colspan="3" %)**Model/Specifications**|=**RE-00**|=**RE-4G**|=**RH-WF** |
44 |
44 |
|(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters** |
45 |
45 |
|(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz |
... |
... |
@@ -84,7 +84,7 @@ |
84 |
84 |
|(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation) |
85 |
85 |
|(% colspan="3" %)CE certification|(% colspan="3" %)Yes |
86 |
86 |
|(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification |
87 |
|
-|(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A |
|
91 |
+|(% colspan="3" style="width:401px" %)Positioning function|(% colspan="2" style="width:401px" %)N/A / Base station positioning|(% style="width:401px" %)N/A |
88 |
88 |
|(% rowspan="7" %)((( |
89 |
89 |
Software |
90 |
90 |
|
... |
... |
@@ -108,6 +108,7 @@ |
108 |
108 |
|
109 |
109 |
**RE-00/RE-4G** |
110 |
110 |
|
|
115 |
+(% style="text-align:center" %) |
111 |
111 |
[[image:1723448311561-814.png]] |
112 |
112 |
|
113 |
113 |
RE-00/RE-4G Component Description |
... |
... |
@@ -166,6 +166,8 @@ |
166 |
166 |
|
167 |
167 |
== **2 Applications** == |
168 |
168 |
|
|
174 |
+=== Basic application === |
|
175 |
+ |
169 |
169 |
R series products, which can easily realize advanced requirements such as real-time display on industrial sites. |
170 |
170 |
|
171 |
171 |
[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]] |
... |
... |
@@ -176,6 +176,23 @@ |
176 |
176 |
|
177 |
177 |
③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software. |
178 |
178 |
|
|
186 |
+ |
|
187 |
+=== RH-WF and WS21 === |
|
188 |
+ |
|
189 |
+RH-WF supports local HDMI interface to connect to in-site screen like a TV screen to display the project. WS21, a touching screen, can be connected with RH-WF via HDMI interface. The project an be operated manually in WS21 screen. |
|
190 |
+ |
|
191 |
+(% style="text-align:center" %) |
|
192 |
+[[image:图片1.png]] |
|
193 |
+ |
|
194 |
+(% style="text-align:center" %) |
|
195 |
+[[image:图片2.png]] |
|
196 |
+ |
|
197 |
+HDMI Port is for displaying the project. And USB Port is for touching. |
|
198 |
+ |
|
199 |
+[[WS21 parameter>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/Wecon%20WS21%20Monitor.pdf]] |
|
200 |
+ |
|
201 |
+[[Demo video>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/RH1.mp4]] |
|
202 |
+ |
179 |
179 |
== **3 Operation Instructions** == |
180 |
180 |
|
181 |
181 |
=== **3.1 Project Download-PIStudio** === |
... |
... |
@@ -493,4 +493,40 @@ |
493 |
493 |
(% style="text-align:center" %) |
494 |
494 |
[[image:rDTHQo0uzs.png]] |
495 |
495 |
|
|
520 |
+== 7 Centralized Monitor == |
|
521 |
+ |
|
522 |
+In HMI V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs and PC are in the same LAN, they can be selected for centralized monitor. |
|
523 |
+ |
|
524 |
+(% class="box infomessage" %) |
|
525 |
+((( |
|
526 |
+Note: Centralized Monitor can not be accomplished by connection that HMIs are connected to PC with USB. |
|
527 |
+))) |
|
528 |
+ |
|
529 |
+=== Local Device === |
|
530 |
+ |
|
531 |
+Download → choose monitored HMIs |
|
532 |
+ |
|
533 |
+(% style="text-align:center" %) |
|
534 |
+[[image:1yeIHMWarO.png]] |
|
535 |
+ |
|
536 |
+=== Cloud Device === |
|
537 |
+ |
|
538 |
+Cloud Linker →log in → select the server in configuration→ log in V-net Client account |
|
539 |
+ |
|
540 |
+(% style="text-align:center" %) |
|
541 |
+[[image:DTQ10E5Cv6.png]] |
|
542 |
+ |
|
543 |
+(% style="text-align:center" %) |
|
544 |
+[[image:IPJDUDCzD4.png]] |
|
545 |
+ |
|
546 |
+After logging in the account, select monitored HMIs. |
|
547 |
+ |
|
548 |
+(% style="text-align:center" %) |
|
549 |
+[[image:y6AlyJtG24.png]] |
|
550 |
+ |
|
551 |
+In Centralized monitor screen, selected HMI project will be display here. What's more, these projects can be operated in the screen. |
|
552 |
+ |
|
553 |
+(% style="text-align:center" %) |
|
554 |
+[[image:MnqsQgF2Cm.png]] |
|
555 |
+ |
496 |
496 |
|