Changes for page R Series

Last modified by Mora Zhou on 2024/12/05 14:34

From version 56.1
edited by Joe
on 2024/11/19 17:20
Change comment: There is no comment for this version
To version 61.1
edited by Mora Zhou
on 2024/12/05 14:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.Mora
Content
... ... @@ -13,10 +13,12 @@
13 13  
14 14  ==== **RE-00/RE-4G** ====
15 15  
16 +(% style="text-align:center" %)
16 16  [[image:1723447082795-273.png]]
17 17  
18 18  RE-00/RE-4G Appearance
19 19  
21 +(% style="text-align:center" %)
20 20  [[image:1723447096815-592.png]]
21 21  
22 22  RE-00/RE-4G Installation Dimensions
... ... @@ -23,6 +23,7 @@
23 23  
24 24  ==== **RH-WF** ====
25 25  
28 +(% style="text-align:center" %)
26 26  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]]
27 27  
28 28  (((
... ... @@ -31,6 +31,7 @@
31 31  
32 32  RH-WF
33 33  
37 +(% style="text-align:center" %)
34 34  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]]
35 35  
36 36  Installation size
... ... @@ -39,7 +39,7 @@
39 39  === **1.2 Product specifications** ===
40 40  
41 41  (((
42 -(% style="width:815px" %)
46 +(% style="width:1075px" %)
43 43  |=(% colspan="3" %)**Model/Specifications**|=**RE-00**|=**RE-4G**|=**RH-WF**
44 44  |(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters**
45 45  |(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz
... ... @@ -84,7 +84,7 @@
84 84  |(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation)
85 85  |(% colspan="3" %)CE certification|(% colspan="3" %)Yes
86 86  |(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification
87 -|(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A
91 +|(% colspan="3" style="width:401px" %)Positioning function|(% colspan="2" style="width:401px" %)N/A  /  Base station positioning|(% style="width:401px" %)N/A
88 88  |(% rowspan="7" %)(((
89 89  Software
90 90  
... ... @@ -108,6 +108,7 @@
108 108  
109 109  **RE-00/RE-4G**
110 110  
115 +(% style="text-align:center" %)
111 111  [[image:1723448311561-814.png]]
112 112  
113 113  RE-00/RE-4G Component Description
... ... @@ -166,6 +166,8 @@
166 166  
167 167  == **2 Applications** ==
168 168  
174 +=== Basic application ===
175 +
169 169  R series products, which can easily realize advanced requirements such as real-time display on industrial sites.
170 170  
171 171  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]]
... ... @@ -176,6 +176,23 @@
176 176  
177 177  ③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software.
178 178  
186 +
187 +=== RH-WF and WS21 ===
188 +
189 +RH-WF supports local HDMI interface to connect to in-site screen like a TV screen to display the project. WS21, a touching screen, can be connected with RH-WF via HDMI interface. The project an be operated manually in WS21 screen.
190 +
191 +(% style="text-align:center" %)
192 +[[image:图片1.png]]
193 +
194 +(% style="text-align:center" %)
195 +[[image:图片2.png]]
196 +
197 +HDMI Port is for displaying the project. And USB Port is for touching.
198 +
199 +[[WS21 parameter>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/Wecon%20WS21%20Monitor.pdf]]
200 +
201 +[[Demo video>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/RH1.mp4]]
202 +
179 179  == **3 Operation Instructions** ==
180 180  
181 181  === **3.1 Project Download-PIStudio** ===
... ... @@ -495,11 +495,16 @@
495 495  
496 496  == 7 Centralized Monitor ==
497 497  
498 -In PI of V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs are connected to PC with USB or HMIs and PC are in the same LAN, they can be selected for centralized monitor.
522 +In HMI V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs and PC are in the same LAN, they can be selected for centralized monitor.
499 499  
524 +(% class="box infomessage" %)
525 +(((
526 +Note: Centralized Monitor can not be accomplished by connection that HMIs are connected to PC with USB.
527 +)))
528 +
500 500  === Local Device ===
501 501  
502 -Download → choose HMIs you want to monitor
531 +Download → choose monitored HMIs
503 503  
504 504  (% style="text-align:center" %)
505 505  [[image:1yeIHMWarO.png]]
... ... @@ -514,12 +514,12 @@
514 514  (% style="text-align:center" %)
515 515  [[image:IPJDUDCzD4.png]]
516 516  
517 -After logging in the account, select HMIs you want to centralized monitor.
546 +After logging in the account, select monitored HMIs.
518 518  
519 519  (% style="text-align:center" %)
520 520  [[image:y6AlyJtG24.png]]
521 521  
522 -In Centralized monitor screen, selected HMI project will be display here. What's more, we can operate remotely in these screens.
551 +In Centralized monitor screen, selected HMI project will be display here. What's more, these projects can be operated in the screen.
523 523  
524 524  (% style="text-align:center" %)
525 525  [[image:MnqsQgF2Cm.png]]
图片1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +213.8 KB
Content
图片2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +117.2 KB
Content