Changes for page R Series

Last modified by Mora Zhou on 2024/12/05 14:34

From version 59.4
edited by Joe
on 2024/11/29 14:46
Change comment: There is no comment for this version
To version 62.1
edited by Mora Zhou
on 2024/12/05 14:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.Mora
Content
... ... @@ -1,4 +1,4 @@
1 -== **1 Product description** ==
1 +== **Product description** ==
2 2  
3 3  |**Series**|(% style="width:132px" %)**Model**|(% style="width:552px" %)**Description**
4 4  |(% rowspan="3" %)**R Series**|(% style="width:132px" %)RE-00|(% style="width:552px" %)1 network port, single serial port
... ... @@ -9,14 +9,16 @@
9 9  2 optocoupler isolated input (DI), 2 relay output (DO)
10 10  )))
11 11  
12 -=== **1.1 Product appearance** ===
12 +=== **Product appearance** ===
13 13  
14 14  ==== **RE-00/RE-4G** ====
15 15  
16 +(% style="text-align:center" %)
16 16  [[image:1723447082795-273.png]]
17 17  
18 18  RE-00/RE-4G Appearance
19 19  
21 +(% style="text-align:center" %)
20 20  [[image:1723447096815-592.png]]
21 21  
22 22  RE-00/RE-4G Installation Dimensions
... ... @@ -23,6 +23,7 @@
23 23  
24 24  ==== **RH-WF** ====
25 25  
28 +(% style="text-align:center" %)
26 26  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]]
27 27  
28 28  (((
... ... @@ -31,15 +31,16 @@
31 31  
32 32  RH-WF
33 33  
37 +(% style="text-align:center" %)
34 34  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]]
35 35  
36 36  Installation size
37 37  
38 38  
39 -=== **1.2 Product specifications** ===
43 +=== **Product specifications** ===
40 40  
41 41  (((
42 -(% style="width:815px" %)
46 +(% style="width:1075px" %)
43 43  |=(% colspan="3" %)**Model/Specifications**|=**RE-00**|=**RE-4G**|=**RH-WF**
44 44  |(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters**
45 45  |(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz
... ... @@ -84,7 +84,7 @@
84 84  |(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation)
85 85  |(% colspan="3" %)CE certification|(% colspan="3" %)Yes
86 86  |(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification
87 -|(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A
91 +|(% colspan="3" style="width:401px" %)Positioning function|(% colspan="2" style="width:401px" %)N/A  /  Base station positioning|(% style="width:401px" %)N/A
88 88  |(% rowspan="7" %)(((
89 89  Software
90 90  
... ... @@ -101,7 +101,7 @@
101 101  |(% colspan="2" %)VPN Pass trough|(% colspan="3" %)Yes
102 102  |(% colspan="2" %)API interface|(% colspan="3" %)Yes
103 103  
104 -=== **1.3 Interface Description** ===
108 +=== **Interface Description** ===
105 105  )))
106 106  
107 107  ==== **Appearance component description** ====
... ... @@ -108,6 +108,7 @@
108 108  
109 109  **RE-00/RE-4G**
110 110  
115 +(% style="text-align:center" %)
111 111  [[image:1723448311561-814.png]]
112 112  
113 113  RE-00/RE-4G Component Description
... ... @@ -164,7 +164,7 @@
164 164  |485-|RS485-
165 165  |GND|Ground
166 166  
167 -== **2 Applications** ==
172 +== **Applications** ==
168 168  
169 169  === Basic application ===
170 170  
... ... @@ -191,12 +191,14 @@
191 191  
192 192  HDMI Port is for displaying the project. And USB Port is for touching.
193 193  
194 -
199 +[[WS21 parameter>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/Wecon%20WS21%20Monitor.pdf]]
195 195  
196 -== **3 Operation Instructions** ==
201 +[[Demo video>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/RH1.mp4]]
197 197  
198 -=== **3.1 Project Download-PIStudio** ===
203 +== **Operation Instructions** ==
199 199  
205 +=== **Project Download-PIStudio** ===
206 +
200 200  **(1) New project**
201 201  
202 202  PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
... ... @@ -224,9 +224,9 @@
224 224  
225 225  **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
226 226  
227 -=== **3.2 Check V-NET IoT System** ===
234 +=== **Check V-NET IoT System** ===
228 228  
229 -==== **3.2.1 V-NET login** ====
236 +==== **V-NET login** ====
230 230  
231 231  (1) New users must register first, and after the registration is successful, the user can use it.
232 232  
... ... @@ -242,7 +242,7 @@
242 242  
243 243  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
244 244  
245 -==== **3.2.2 Adding devices** ====
252 +==== **Adding devices** ====
246 246  
247 247  (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
248 248  
... ... @@ -264,7 +264,7 @@
264 264  
265 265   (3) Binding device is successful, click OK, prompt: Bind device successful!
266 266  
267 -==== **3.2.3 V-NET check** ====
274 +==== **V-NET check** ====
268 268  
269 269  **(1) Remote monitoring**
270 270  
... ... @@ -328,7 +328,7 @@
328 328  **Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.**
329 329  
330 330  
331 -== **4 Pass-through of device** ==
338 +== **Pass-through of device** ==
332 332  
333 333  **Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
334 334  
... ... @@ -361,7 +361,7 @@
361 361  ● When the current user has a device in pass-through, “Start pass-through” cannot be clicked.
362 362  
363 363  
364 -=== **4.1 Device pass-through download (RE)** ===
371 +=== **Device pass-through download (RE)** ===
365 365  
366 366  The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet.
367 367  
... ... @@ -385,7 +385,7 @@
385 385  
386 386  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
387 387  
388 -=== **4.2 Common serial port pass-through (PLC)** ===
395 +=== **Common serial port pass-through (PLC)** ===
389 389  
390 390  Based on the normal communication between RE device and PLC or other device, PLC is connected according to the generated virtual serial port, allowing the PLC software on the computer to communicate and connect with the PLC, and completing the functions of uploading/downloading PLC programs and monitoring PLC programs.
391 391  
... ... @@ -423,7 +423,7 @@
423 423  
424 424  ④ It is necessary to ensure that the PLC serial port of pass-through can support the upload/download function, otherwise the remote pass-through function cannot be realized.
425 425  
426 -=== **4.3 VPN pass-through (PLC)** ===
433 +=== **VPN pass-through (PLC)** ===
427 427  
428 428  **VPN pass-through:** The pass-through function allows the application program on the computer to directly control the PLC device through the RE device, upload/download PLC programs, monitor PLC programs or other configuration information, etc.
429 429  
... ... @@ -457,7 +457,7 @@
457 457  
458 458  [[https:~~/~~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf>>https://www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf]]
459 459  
460 -== 5 Resumable upload ==
467 +== Resumable upload ==
461 461  
462 462  3000ig/8000ig HMI and RE/RH,E/H V-BOX can support  a function for resumable upload. The function is to save lost data when the device is offline and upload lost data to Cloud when the device is online again.
463 463  
... ... @@ -476,7 +476,7 @@
476 476  2.When the device is online again, There is a keep-alive interval for about 30s. So data will be lost during the time.
477 477  )))
478 478  
479 -== 6 Remote Background ==
486 +== Remote Background ==
480 480  
481 481  R series box doesn’t have the actual screen, so a new remote page is designed for background setting if user want to change some background parameters.
482 482  
... ... @@ -510,7 +510,7 @@
510 510  (% style="text-align:center" %)
511 511  [[image:rDTHQo0uzs.png]]
512 512  
513 -== 7 Centralized Monitor ==
520 +== Centralized Monitor ==
514 514  
515 515  In HMI V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs and PC are in the same LAN, they can be selected for centralized monitor.
516 516