Changes for page R Series

Last modified by Mora Zhou on 2024/12/05 14:34

From version 60.1
edited by Joe
on 2024/11/29 15:16
Change comment: There is no comment for this version
To version 62.1
edited by Mora Zhou
on 2024/12/05 14:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.Mora
Content
... ... @@ -1,4 +1,4 @@
1 -== **1 Product description** ==
1 +== **Product description** ==
2 2  
3 3  |**Series**|(% style="width:132px" %)**Model**|(% style="width:552px" %)**Description**
4 4  |(% rowspan="3" %)**R Series**|(% style="width:132px" %)RE-00|(% style="width:552px" %)1 network port, single serial port
... ... @@ -9,14 +9,16 @@
9 9  2 optocoupler isolated input (DI), 2 relay output (DO)
10 10  )))
11 11  
12 -=== **1.1 Product appearance** ===
12 +=== **Product appearance** ===
13 13  
14 14  ==== **RE-00/RE-4G** ====
15 15  
16 +(% style="text-align:center" %)
16 16  [[image:1723447082795-273.png]]
17 17  
18 18  RE-00/RE-4G Appearance
19 19  
21 +(% style="text-align:center" %)
20 20  [[image:1723447096815-592.png]]
21 21  
22 22  RE-00/RE-4G Installation Dimensions
... ... @@ -23,6 +23,7 @@
23 23  
24 24  ==== **RH-WF** ====
25 25  
28 +(% style="text-align:center" %)
26 26  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]]
27 27  
28 28  (((
... ... @@ -31,15 +31,16 @@
31 31  
32 32  RH-WF
33 33  
37 +(% style="text-align:center" %)
34 34  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]]
35 35  
36 36  Installation size
37 37  
38 38  
39 -=== **1.2 Product specifications** ===
43 +=== **Product specifications** ===
40 40  
41 41  (((
42 -(% style="width:815px" %)
46 +(% style="width:1075px" %)
43 43  |=(% colspan="3" %)**Model/Specifications**|=**RE-00**|=**RE-4G**|=**RH-WF**
44 44  |(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters**
45 45  |(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz
... ... @@ -84,7 +84,7 @@
84 84  |(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation)
85 85  |(% colspan="3" %)CE certification|(% colspan="3" %)Yes
86 86  |(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification
87 -|(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A
91 +|(% colspan="3" style="width:401px" %)Positioning function|(% colspan="2" style="width:401px" %)N/A  /  Base station positioning|(% style="width:401px" %)N/A
88 88  |(% rowspan="7" %)(((
89 89  Software
90 90  
... ... @@ -101,7 +101,7 @@
101 101  |(% colspan="2" %)VPN Pass trough|(% colspan="3" %)Yes
102 102  |(% colspan="2" %)API interface|(% colspan="3" %)Yes
103 103  
104 -=== **1.3 Interface Description** ===
108 +=== **Interface Description** ===
105 105  )))
106 106  
107 107  ==== **Appearance component description** ====
... ... @@ -108,6 +108,7 @@
108 108  
109 109  **RE-00/RE-4G**
110 110  
115 +(% style="text-align:center" %)
111 111  [[image:1723448311561-814.png]]
112 112  
113 113  RE-00/RE-4G Component Description
... ... @@ -164,7 +164,7 @@
164 164  |485-|RS485-
165 165  |GND|Ground
166 166  
167 -== **2 Applications** ==
172 +== **Applications** ==
168 168  
169 169  === Basic application ===
170 170  
... ... @@ -195,9 +195,9 @@
195 195  
196 196  [[Demo video>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/RH1.mp4]]
197 197  
198 -== **3 Operation Instructions** ==
203 +== **Operation Instructions** ==
199 199  
200 -=== **3.1 Project Download-PIStudio** ===
205 +=== **Project Download-PIStudio** ===
201 201  
202 202  **(1) New project**
203 203  
... ... @@ -226,9 +226,9 @@
226 226  
227 227  **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
228 228  
229 -=== **3.2 Check V-NET IoT System** ===
234 +=== **Check V-NET IoT System** ===
230 230  
231 -==== **3.2.1 V-NET login** ====
236 +==== **V-NET login** ====
232 232  
233 233  (1) New users must register first, and after the registration is successful, the user can use it.
234 234  
... ... @@ -244,7 +244,7 @@
244 244  
245 245  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
246 246  
247 -==== **3.2.2 Adding devices** ====
252 +==== **Adding devices** ====
248 248  
249 249  (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
250 250  
... ... @@ -266,7 +266,7 @@
266 266  
267 267   (3) Binding device is successful, click OK, prompt: Bind device successful!
268 268  
269 -==== **3.2.3 V-NET check** ====
274 +==== **V-NET check** ====
270 270  
271 271  **(1) Remote monitoring**
272 272  
... ... @@ -330,7 +330,7 @@
330 330  **Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.**
331 331  
332 332  
333 -== **4 Pass-through of device** ==
338 +== **Pass-through of device** ==
334 334  
335 335  **Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
336 336  
... ... @@ -363,7 +363,7 @@
363 363  ● When the current user has a device in pass-through, “Start pass-through” cannot be clicked.
364 364  
365 365  
366 -=== **4.1 Device pass-through download (RE)** ===
371 +=== **Device pass-through download (RE)** ===
367 367  
368 368  The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet.
369 369  
... ... @@ -387,7 +387,7 @@
387 387  
388 388  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
389 389  
390 -=== **4.2 Common serial port pass-through (PLC)** ===
395 +=== **Common serial port pass-through (PLC)** ===
391 391  
392 392  Based on the normal communication between RE device and PLC or other device, PLC is connected according to the generated virtual serial port, allowing the PLC software on the computer to communicate and connect with the PLC, and completing the functions of uploading/downloading PLC programs and monitoring PLC programs.
393 393  
... ... @@ -425,7 +425,7 @@
425 425  
426 426  ④ It is necessary to ensure that the PLC serial port of pass-through can support the upload/download function, otherwise the remote pass-through function cannot be realized.
427 427  
428 -=== **4.3 VPN pass-through (PLC)** ===
433 +=== **VPN pass-through (PLC)** ===
429 429  
430 430  **VPN pass-through:** The pass-through function allows the application program on the computer to directly control the PLC device through the RE device, upload/download PLC programs, monitor PLC programs or other configuration information, etc.
431 431  
... ... @@ -459,7 +459,7 @@
459 459  
460 460  [[https:~~/~~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf>>https://www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf]]
461 461  
462 -== 5 Resumable upload ==
467 +== Resumable upload ==
463 463  
464 464  3000ig/8000ig HMI and RE/RH,E/H V-BOX can support  a function for resumable upload. The function is to save lost data when the device is offline and upload lost data to Cloud when the device is online again.
465 465  
... ... @@ -478,7 +478,7 @@
478 478  2.When the device is online again, There is a keep-alive interval for about 30s. So data will be lost during the time.
479 479  )))
480 480  
481 -== 6 Remote Background ==
486 +== Remote Background ==
482 482  
483 483  R series box doesn’t have the actual screen, so a new remote page is designed for background setting if user want to change some background parameters.
484 484  
... ... @@ -512,7 +512,7 @@
512 512  (% style="text-align:center" %)
513 513  [[image:rDTHQo0uzs.png]]
514 514  
515 -== 7 Centralized Monitor ==
520 +== Centralized Monitor ==
516 516  
517 517  In HMI V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs and PC are in the same LAN, they can be selected for centralized monitor.
518 518