Changes for page R Series

Last modified by Mora Zhou on 2024/12/05 14:34

From version 62.1
edited by Mora Zhou
on 2024/12/05 14:19
Change comment: There is no comment for this version
To version 66.1
edited by Mora Zhou
on 2024/12/05 14:29
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -123,6 +123,7 @@
123 123  
124 124  **RH-WF**
125 125  
126 +(% style="text-align:center" %)
126 126  [[image:1723448356737-113.png]]
127 127  
128 128  RH-WF Component Description
... ... @@ -175,6 +175,7 @@
175 175  
176 176  R series products, which can easily realize advanced requirements such as real-time display on industrial sites.
177 177  
179 +(% style="text-align:center" %)
178 178  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]]
179 179  
180 180  ① Large-screen display, connect computer/TV Display the project screen;
... ... @@ -208,6 +208,7 @@
208 208  
209 209  PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
210 210  
213 +(% style="text-align:center" %)
211 211  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8971673d.png||height="340" width="638"]]
212 212  
213 213  **(2) Enable cloud server**
... ... @@ -219,6 +219,7 @@
219 219  Upload to the cloud: All configured tag information, historical information, and alarm information will be pushed to V-NET.
220 220  
221 221  
225 +(% style="text-align:center" %)
222 222  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_19762229.png||height="360" width="638"]]
223 223  
224 224  **(3) Project compile/download**
... ... @@ -225,8 +225,10 @@
225 225  
226 226  After the project is completed, click **[Project Compile]**→After prompting that the compilation is completed, click** [Download Project]**→device detected, **[PC port]**. Ethernet or USB download→[PC→HMI]→pop up a prompt, click **[OK]** → complete the configuration project download, it will take effect after restart.
227 227  
232 +(% style="text-align:center" %)
228 228  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_38834748.png||height="340" width="634"]]
229 229  
235 +(% style="text-align:center" %)
230 230  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_31fafd4e.png||height="287" width="348"]]
231 231  
232 232  **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
... ... @@ -241,6 +241,7 @@
241 241  
242 242  ● Users need to remember the registered account and password, and can log in simultaneously on the PC/APP.
243 243  
250 +(% style="text-align:center" %)
244 244  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_7103ee91.png||height="274" width="453"]]
245 245  
246 246  (2) Enter the account and password, and then click the **[Log in] **button.
... ... @@ -247,6 +247,7 @@
247 247  
248 248  (3) After admin account logs in to the platform, it will jump to the homepage by default, as shown in the figure below.
249 249  
257 +(% style="text-align:center" %)
250 250  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
251 251  
252 252  ==== **Adding devices** ====
... ... @@ -253,6 +253,7 @@
253 253  
254 254  (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
255 255  
264 +(% style="text-align:center" %)
256 256  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_45c9855a.png||height="409" width="638"]]
257 257  
258 258  (2) After the **[Add Device]** window pops up, enter the device machine code and password, etc., and add the device. Other instructions are as follows:   
... ... @@ -277,6 +277,7 @@
277 277  
278 278  The remote monitoring module can display the current screen in real time, and realize the operation of the project on the web page, realize the remote monitoring of the device and the control of the screen.
279 279  
289 +(% style="text-align:center" %)
280 280  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a262a004.png||height="362" width="638"]]
281 281  
282 282  **(2) Data viewing**
... ... @@ -283,6 +283,7 @@
283 283  
284 284  Data view has six modules, including Communication port, Collection point, Alarm configuration, Alarm record, Historical configuration, Historical data record.
285 285  
296 +(% style="text-align:center" %)
286 286  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_6ce8af63.png||height="357" width="638"]]
287 287  
288 288  **The specific parameter is as follows:**
... ... @@ -299,6 +299,7 @@
299 299  
300 300  The cloud SCADA platform is mainly used to display the monitoring/operation interface of the bound device in the V-NET.
301 301  
313 +(% style="text-align:center" %)
302 302  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8ecdd915.png||height="332" width="638"]]
303 303  
304 304   The main functions of Cloud SCADA interface in device management are as follows:
... ... @@ -316,6 +316,7 @@
316 316  
317 317  Include: "Basic information, status push, register information, version information" for the device.
318 318  
331 +(% style="text-align:center" %)
319 319  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_b1d4b150.png||height="330" width="638"]]
320 320  
321 321  ●**Device name:** Mainly used to distinguish various devices.
... ... @@ -334,7 +334,6 @@
334 334  
335 335  **Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.**
336 336  
337 -
338 338  == **Pass-through of device** ==
339 339  
340 340  **Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
... ... @@ -341,6 +341,7 @@
341 341  
342 342  Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc.
343 343  
356 +(% style="text-align:center" %)
344 344  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1c4453d8.png||height="338" width="638"]]
345 345  
346 346  Device status description table is as follows:
... ... @@ -390,6 +390,7 @@
390 390  
391 391  ⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program.
392 392  
406 +(% style="text-align:center" %)
393 393  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
394 394  
395 395  === **Common serial port pass-through (PLC)** ===
... ... @@ -400,14 +400,17 @@
400 400  
401 401  ① Virtual serial port settings: Click** [Settings]** →**[Virtual Serial Port]**→**[Enable Virtual Serial Port] **→**[Select Serial Port]**. Pay attention to the serial port, please do not reuse it. (When the COM port is changed, if a PLC or other software is connecting to the original COM port, it will be disconnected.)
402 402  
417 +(% style="text-align:center" %)
403 403  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_54a850e2.png||height="136" width="639"]]
404 404  
405 405  ② Remote download configuration: Click [PLC pass-through ][[image:Wecon V-BOX R Series User Manual 240611 V1.2_cfc415e2.png||height="14" width="15"]] →Select the device that requires pass-through→[New/Edit]→[New Template] Configure pass-through parameters: [Name], [Communication Port], [Connection Method], [Baud Rate], [Stop Bit], [Data Bit], [Check Bit], the configured parameters need to be consistent with the PLC serial port parameters →[OK]→Prompt "Add successfully!"→[OK].
406 406  
422 +(% style="text-align:center" %)
407 407  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_353545eb.png||height="339" width="638"]]
408 408  
409 409  ③ Pass-through steps: On the pass-through interface, click [Start pass-through]→after successful pass-through, it will prompt "pass-through succeeded"→[OK].
410 410  
427 +(% style="text-align:center" %)
411 411  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_5b5ad7dd.png||height="339" width="638"]]
412 412  
413 413  ④ After the pass-through is successful, the indicator light of the corresponding RE device on the PC will turn blue, and the [current status] will become pass-through, indicating that the device is in the "pass-through" status.
... ... @@ -418,6 +418,7 @@
418 418  
419 419  ⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored.
420 420  
438 +(% style="text-align:center" %)
421 421  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]]
422 422  
423 423  **Pass-through Precautions:**
... ... @@ -438,16 +438,19 @@
438 438  
439 439  ① Click [VPN pass-through] [[image:1723450415577-521.png]]→Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK].
440 440  
441 -[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]]
459 +(% style="text-align:center" %)
460 +[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png]]
442 442  
443 443  ② After pass-through is successful, the indicator light of the corresponding RE device on the PC will turn yellow, and [current status] will become in the VPN pass-through, indicating that the device is in the "pass-through" status. (**Note:** You cannot click [End pass-through], otherwise you will exit the pass-through.)
444 444  
445 445  ③ After the pass-through is successful, a virtual network card will be generated. You can check whether the IP is generated through the network card of the computer, as shown below.
446 446  
466 +(% style="text-align:center" %)
447 447  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a53a8121.png||height="336" width="638"]]
448 448  
449 449  ④ When PLC software completes the remote operation, select [End pass-through]→Prompt "End VPN pass through successfully"→[OK], at this time the device will automatically restart, and after the restart is completed, the working status before pass-through will be restored.
450 450  
471 +(% style="text-align:center" %)
451 451  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_40416c98.png||height="336" width="638"]]
452 452  
453 453  **Pass-through precautions:**