Summary

Details

Page properties
Content
... ... @@ -210,6 +210,7 @@
210 210  
211 211  PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
212 212  
213 +(% style="text-align:center" %)
213 213  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8971673d.png||height="340" width="638"]]
214 214  
215 215  **(2) Enable cloud server**
... ... @@ -221,6 +221,7 @@
221 221  Upload to the cloud: All configured tag information, historical information, and alarm information will be pushed to V-NET.
222 222  
223 223  
225 +(% style="text-align:center" %)
224 224  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_19762229.png||height="360" width="638"]]
225 225  
226 226  **(3) Project compile/download**
... ... @@ -227,8 +227,10 @@
227 227  
228 228  After the project is completed, click **[Project Compile]**→After prompting that the compilation is completed, click** [Download Project]**→device detected, **[PC port]**. Ethernet or USB download→[PC→HMI]→pop up a prompt, click **[OK]** → complete the configuration project download, it will take effect after restart.
229 229  
232 +(% style="text-align:center" %)
230 230  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_38834748.png||height="340" width="634"]]
231 231  
235 +(% style="text-align:center" %)
232 232  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_31fafd4e.png||height="287" width="348"]]
233 233  
234 234  **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
... ... @@ -243,6 +243,7 @@
243 243  
244 244  ● Users need to remember the registered account and password, and can log in simultaneously on the PC/APP.
245 245  
250 +(% style="text-align:center" %)
246 246  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_7103ee91.png||height="274" width="453"]]
247 247  
248 248  (2) Enter the account and password, and then click the **[Log in] **button.
... ... @@ -249,6 +249,7 @@
249 249  
250 250  (3) After admin account logs in to the platform, it will jump to the homepage by default, as shown in the figure below.
251 251  
257 +(% style="text-align:center" %)
252 252  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
253 253  
254 254  ==== **Adding devices** ====
... ... @@ -255,6 +255,7 @@
255 255  
256 256  (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
257 257  
264 +(% style="text-align:center" %)
258 258  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_45c9855a.png||height="409" width="638"]]
259 259  
260 260  (2) After the **[Add Device]** window pops up, enter the device machine code and password, etc., and add the device. Other instructions are as follows:   
... ... @@ -279,6 +279,7 @@
279 279  
280 280  The remote monitoring module can display the current screen in real time, and realize the operation of the project on the web page, realize the remote monitoring of the device and the control of the screen.
281 281  
289 +(% style="text-align:center" %)
282 282  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a262a004.png||height="362" width="638"]]
283 283  
284 284  **(2) Data viewing**
... ... @@ -285,6 +285,7 @@
285 285  
286 286  Data view has six modules, including Communication port, Collection point, Alarm configuration, Alarm record, Historical configuration, Historical data record.
287 287  
296 +(% style="text-align:center" %)
288 288  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_6ce8af63.png||height="357" width="638"]]
289 289  
290 290  **The specific parameter is as follows:**
... ... @@ -301,6 +301,7 @@
301 301  
302 302  The cloud SCADA platform is mainly used to display the monitoring/operation interface of the bound device in the V-NET.
303 303  
313 +(% style="text-align:center" %)
304 304  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8ecdd915.png||height="332" width="638"]]
305 305  
306 306   The main functions of Cloud SCADA interface in device management are as follows:
... ... @@ -318,6 +318,7 @@
318 318  
319 319  Include: "Basic information, status push, register information, version information" for the device.
320 320  
331 +(% style="text-align:center" %)
321 321  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_b1d4b150.png||height="330" width="638"]]
322 322  
323 323  ●**Device name:** Mainly used to distinguish various devices.
... ... @@ -336,7 +336,6 @@
336 336  
337 337  **Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.**
338 338  
339 -
340 340  == **Pass-through of device** ==
341 341  
342 342  **Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
... ... @@ -343,6 +343,7 @@
343 343  
344 344  Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc.
345 345  
356 +(% style="text-align:center" %)
346 346  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1c4453d8.png||height="338" width="638"]]
347 347  
348 348  Device status description table is as follows:
... ... @@ -392,6 +392,7 @@
392 392  
393 393  ⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program.
394 394  
406 +(% style="text-align:center" %)
395 395  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
396 396  
397 397  === **Common serial port pass-through (PLC)** ===
... ... @@ -402,14 +402,17 @@
402 402  
403 403  ① Virtual serial port settings: Click** [Settings]** →**[Virtual Serial Port]**→**[Enable Virtual Serial Port] **→**[Select Serial Port]**. Pay attention to the serial port, please do not reuse it. (When the COM port is changed, if a PLC or other software is connecting to the original COM port, it will be disconnected.)
404 404  
417 +(% style="text-align:center" %)
405 405  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_54a850e2.png||height="136" width="639"]]
406 406  
407 407  ② Remote download configuration: Click [PLC pass-through ][[image:Wecon V-BOX R Series User Manual 240611 V1.2_cfc415e2.png||height="14" width="15"]] →Select the device that requires pass-through→[New/Edit]→[New Template] Configure pass-through parameters: [Name], [Communication Port], [Connection Method], [Baud Rate], [Stop Bit], [Data Bit], [Check Bit], the configured parameters need to be consistent with the PLC serial port parameters →[OK]→Prompt "Add successfully!"→[OK].
408 408  
422 +(% style="text-align:center" %)
409 409  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_353545eb.png||height="339" width="638"]]
410 410  
411 411  ③ Pass-through steps: On the pass-through interface, click [Start pass-through]→after successful pass-through, it will prompt "pass-through succeeded"→[OK].
412 412  
427 +(% style="text-align:center" %)
413 413  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_5b5ad7dd.png||height="339" width="638"]]
414 414  
415 415  ④ After the pass-through is successful, the indicator light of the corresponding RE device on the PC will turn blue, and the [current status] will become pass-through, indicating that the device is in the "pass-through" status.
... ... @@ -420,6 +420,7 @@
420 420  
421 421  ⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored.
422 422  
438 +(% style="text-align:center" %)
423 423  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]]
424 424  
425 425  **Pass-through Precautions:**
... ... @@ -440,16 +440,19 @@
440 440  
441 441  ① Click [VPN pass-through] [[image:1723450415577-521.png]]→Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK].
442 442  
443 -[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]]
459 +(% style="text-align:center" %)
460 +[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png]]
444 444  
445 445  ② After pass-through is successful, the indicator light of the corresponding RE device on the PC will turn yellow, and [current status] will become in the VPN pass-through, indicating that the device is in the "pass-through" status. (**Note:** You cannot click [End pass-through], otherwise you will exit the pass-through.)
446 446  
447 447  ③ After the pass-through is successful, a virtual network card will be generated. You can check whether the IP is generated through the network card of the computer, as shown below.
448 448  
466 +(% style="text-align:center" %)
449 449  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a53a8121.png||height="336" width="638"]]
450 450  
451 451  ④ When PLC software completes the remote operation, select [End pass-through]→Prompt "End VPN pass through successfully"→[OK], at this time the device will automatically restart, and after the restart is completed, the working status before pass-through will be restored.
452 452  
471 +(% style="text-align:center" %)