Changes for page R Series

Last modified by Mora Zhou on 2024/12/05 14:34

From version 67.1
edited by Mora Zhou
on 2024/12/05 14:34
Change comment: There is no comment for this version
To version 64.1
edited by Mora Zhou
on 2024/12/05 14:24
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -136,14 +136,12 @@
136 136  
137 137  **RE-00/RE-4G**
138 138  
139 -(% style="text-align:center" %)
140 140  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d215ad34.png||height="276" width="616"]]
141 141  
142 142  
143 143  **RH-WF**
144 144  
145 -(% style="text-align:center" %)
146 -[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png]]
144 +[[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]]
147 147  
148 148  ==== **Interface Definition** ====
149 149  
... ... @@ -212,7 +212,6 @@
212 212  
213 213  PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
214 214  
215 -(% style="text-align:center" %)
216 216  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8971673d.png||height="340" width="638"]]
217 217  
218 218  **(2) Enable cloud server**
... ... @@ -224,7 +224,6 @@
224 224  Upload to the cloud: All configured tag information, historical information, and alarm information will be pushed to V-NET.
225 225  
226 226  
227 -(% style="text-align:center" %)
228 228  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_19762229.png||height="360" width="638"]]
229 229  
230 230  **(3) Project compile/download**
... ... @@ -231,10 +231,8 @@
231 231  
232 232  After the project is completed, click **[Project Compile]**→After prompting that the compilation is completed, click** [Download Project]**→device detected, **[PC port]**. Ethernet or USB download→[PC→HMI]→pop up a prompt, click **[OK]** → complete the configuration project download, it will take effect after restart.
233 233  
234 -(% style="text-align:center" %)
235 235  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_38834748.png||height="340" width="634"]]
236 236  
237 -(% style="text-align:center" %)
238 238  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_31fafd4e.png||height="287" width="348"]]
239 239  
240 240  **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
... ... @@ -249,7 +249,6 @@
249 249  
250 250  ● Users need to remember the registered account and password, and can log in simultaneously on the PC/APP.
251 251  
252 -(% style="text-align:center" %)
253 253  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_7103ee91.png||height="274" width="453"]]
254 254  
255 255  (2) Enter the account and password, and then click the **[Log in] **button.
... ... @@ -256,7 +256,6 @@
256 256  
257 257  (3) After admin account logs in to the platform, it will jump to the homepage by default, as shown in the figure below.
258 258  
259 -(% style="text-align:center" %)
260 260  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
261 261  
262 262  ==== **Adding devices** ====
... ... @@ -263,7 +263,6 @@
263 263  
264 264  (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
265 265  
266 -(% style="text-align:center" %)
267 267  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_45c9855a.png||height="409" width="638"]]
268 268  
269 269  (2) After the **[Add Device]** window pops up, enter the device machine code and password, etc., and add the device. Other instructions are as follows:   
... ... @@ -288,7 +288,6 @@
288 288  
289 289  The remote monitoring module can display the current screen in real time, and realize the operation of the project on the web page, realize the remote monitoring of the device and the control of the screen.
290 290  
291 -(% style="text-align:center" %)
292 292  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a262a004.png||height="362" width="638"]]
293 293  
294 294  **(2) Data viewing**
... ... @@ -295,7 +295,6 @@
295 295  
296 296  Data view has six modules, including Communication port, Collection point, Alarm configuration, Alarm record, Historical configuration, Historical data record.
297 297  
298 -(% style="text-align:center" %)
299 299  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_6ce8af63.png||height="357" width="638"]]
300 300  
301 301  **The specific parameter is as follows:**
... ... @@ -312,7 +312,6 @@
312 312  
313 313  The cloud SCADA platform is mainly used to display the monitoring/operation interface of the bound device in the V-NET.
314 314  
315 -(% style="text-align:center" %)
316 316  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8ecdd915.png||height="332" width="638"]]
317 317  
318 318   The main functions of Cloud SCADA interface in device management are as follows:
... ... @@ -330,7 +330,6 @@
330 330  
331 331  Include: "Basic information, status push, register information, version information" for the device.
332 332  
333 -(% style="text-align:center" %)
334 334  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_b1d4b150.png||height="330" width="638"]]
335 335  
336 336  ●**Device name:** Mainly used to distinguish various devices.
... ... @@ -349,6 +349,7 @@
349 349  
350 350  **Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.**
351 351  
339 +
352 352  == **Pass-through of device** ==
353 353  
354 354  **Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
... ... @@ -355,7 +355,6 @@
355 355  
356 356  Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc.
357 357  
358 -(% style="text-align:center" %)
359 359  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1c4453d8.png||height="338" width="638"]]
360 360  
361 361  Device status description table is as follows:
... ... @@ -405,7 +405,6 @@
405 405  
406 406  ⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program.
407 407  
408 -(% style="text-align:center" %)
409 409  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
410 410  
411 411  === **Common serial port pass-through (PLC)** ===
... ... @@ -416,17 +416,14 @@
416 416  
417 417  ① Virtual serial port settings: Click** [Settings]** →**[Virtual Serial Port]**→**[Enable Virtual Serial Port] **→**[Select Serial Port]**. Pay attention to the serial port, please do not reuse it. (When the COM port is changed, if a PLC or other software is connecting to the original COM port, it will be disconnected.)
418 418  
419 -(% style="text-align:center" %)
420 420  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_54a850e2.png||height="136" width="639"]]
421 421  
422 422  ② Remote download configuration: Click [PLC pass-through ][[image:Wecon V-BOX R Series User Manual 240611 V1.2_cfc415e2.png||height="14" width="15"]] →Select the device that requires pass-through→[New/Edit]→[New Template] Configure pass-through parameters: [Name], [Communication Port], [Connection Method], [Baud Rate], [Stop Bit], [Data Bit], [Check Bit], the configured parameters need to be consistent with the PLC serial port parameters →[OK]→Prompt "Add successfully!"→[OK].
423 423  
424 -(% style="text-align:center" %)
425 425  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_353545eb.png||height="339" width="638"]]
426 426  
427 427  ③ Pass-through steps: On the pass-through interface, click [Start pass-through]→after successful pass-through, it will prompt "pass-through succeeded"→[OK].
428 428  
429 -(% style="text-align:center" %)
430 430  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_5b5ad7dd.png||height="339" width="638"]]
431 431  
432 432  ④ After the pass-through is successful, the indicator light of the corresponding RE device on the PC will turn blue, and the [current status] will become pass-through, indicating that the device is in the "pass-through" status.
... ... @@ -437,7 +437,6 @@
437 437  
438 438  ⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored.
439 439  
440 -(% style="text-align:center" %)
441 441  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]]
442 442  
443 443  **Pass-through Precautions:**
... ... @@ -458,19 +458,16 @@
458 458  
459 459  ① Click [VPN pass-through] [[image:1723450415577-521.png]]→Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK].
460 460  
461 -(% style="text-align:center" %)
462 -[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png]]
443 +[[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]]
463 463  
464 464  ② After pass-through is successful, the indicator light of the corresponding RE device on the PC will turn yellow, and [current status] will become in the VPN pass-through, indicating that the device is in the "pass-through" status. (**Note:** You cannot click [End pass-through], otherwise you will exit the pass-through.)
465 465  
466 466  ③ After the pass-through is successful, a virtual network card will be generated. You can check whether the IP is generated through the network card of the computer, as shown below.
467 467  
468 -(% style="text-align:center" %)
469 469  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a53a8121.png||height="336" width="638"]]
470 470  
471 471  ④ When PLC software completes the remote operation, select [End pass-through]→Prompt "End VPN pass through successfully"→[OK], at this time the device will automatically restart, and after the restart is completed, the working status before pass-through will be restored.
472 472  
473 -(% style="text-align:center" %)
474 474  [[image:Wecon V-BOX R Series User Manual 240611 V1.2_40416c98.png||height="336" width="638"]]
475 475  
476 476  **Pass-through precautions:**