Wiki source code of R Series

Version 2.1 by Mora Zhou on 2024/08/12 15:07

Show last authors
1
2
3
4
5
6 **Wecon V-BOX**
7
8 **R Series**
9
10 **User Manual**
11
12 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1685bbf5.png||height="599" width="791"]] [[image:Wecon V-BOX R Series User Manual 240611 V1.2_e8e0fa8f.png||height="36" width="194"]]\\
13
14 {{id name="_Toc4324"/}}{{id name="_Toc31841"/}}**Wecon V-BOX R Series User Manual**
15
16 == **1 Product description** ==
17
18 |**Series**|**Model**|**Description**
19 |(% rowspan="3" %)**R Series**|RE-00|1 network port, single serial port
20 |RE-4G|1 network port, single serial port, support 4G.
21 |RH-WF|(((
22 2 network ports, 1 HDMI interface, single serial port, 2 RS485 terminals, support WiFi
23
24 2 optocoupler isolated input (DI), 2relay output (DO)
25 )))
26
27 === {{id name="_Toc23291"/}}{{id name="_Toc3858"/}}**1.1 Product appearance** ===
28
29 ==== {{id name="_Toc21531"/}}**(1)RE-00/RE-4G** ====
30
31 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_eae14981.png||height="305" width="273"]]
32
33 RE-00/RE-4G Appearance
34
35 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59f1285c.gif||height="259" width="643"]]
36
37 RE-00/RE-4G Installation Dimensions
38
39 ==== {{id name="_Toc15014"/}}**(2) RH-WF** ====
40
41 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]]
42
43 (((
44
45 **WiFi antenna**
46
47 )))
48
49 RH-WF
50
51 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]]
52
53 {{id name="_Toc7941"/}}Installation Size
54
55
56
57
58
59
60 === {{id name="_Toc7987"/}}**1.2 Product specifications** ===
61
62 === {{id name="_Toc16174"/}}{{id name="_Toc12326"/}} ===
63
64 (((
65 |(% colspan="3" %)**Model/Specifications**|**RE-00**|**RE-4G**|**RH-WF**
66 |(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters**
67 |(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz
68 |(% rowspan="3" %)Memory|(% colspan="2" %)Flash|(% colspan="2" %)128MB|8GB
69 |(% colspan="2" %)RAM|(% colspan="2" %)DDRII 64MB|2GB
70 |(% colspan="2" %)SD Card|(% colspan="2" %)N/A|TF card
71 |(% rowspan="8" %)(((
72 I/O
73
74 Interface
75 )))|(% colspan="2" %)USB HOST|(% colspan="2" %)1, no isolation|(((
76 USB 2.0*1 No isolation
77
78 USB 3.0*1 No isolation
79 )))
80 |(% colspan="2" %)USB DEVICE|(% colspan="2" %)1, no isolation|Type-C*1
81 |(% colspan="2" %)Serial port|(% colspan="2" %)COM1: RS232, RS422/RS485|(((
82 COM1: RS232, RS422/RS485 (2 in 1)
83
84 1 expansion serial port (terminal line)
85
86 [COM2: RS485]
87 )))
88 |(% colspan="2" %)Ethernet port|(% colspan="2" %)1|10/100M Interface*2
89 |(% colspan="2" %)WIFI module|(% colspan="2" %)N/A|Yes
90 |(% colspan="2" %)4G module|N/A|4G|N/A
91 |(% colspan="2" %)HDMI|(% colspan="2" %)N/A|HDMI 2.0*1
92 |(% colspan="2" %)I/O|(% colspan="2" %)N/A|2-channel relay output, 2-channel isolated input with optocoupler
93 |(% rowspan="2" %)Power supply|(% colspan="2" %)Input power supply|(% colspan="3" %)24V DC (12-28V DC)
94 |(% colspan="2" %)Power consumption|(% colspan="3" %)<10W
95 |(% rowspan="4" %)Specifications|(% colspan="2" %)Shell material|(% colspan="2" %)Cold rolled sheet|Engineering-plastics PC+AB5 (Flame retardant level)
96 |(% colspan="2" %)Dimensions (W*H*D)|(% colspan="2" %)101.0*73.2*26.8mm|125.0*93.7*51.0 mm
97 |(% colspan="2" %)Wall mounting hole dimensions|(% colspan="2" %)110.0*15.6 mm|/(Fastener mounting)
98 |(% colspan="2" %)Weight|(% colspan="2" %)0.26Kg|253g
99 |(% rowspan="4" %)(((
100 Operation
101
102 Environment
103 )))|(% colspan="2" %)Vibration resistance|(% colspan="3" %)Compile with IEC61131-2 standard
104 |(% colspan="2" %)Storage temperature|(% colspan="3" %)-20℃-70℃
105 |(% colspan="2" %)Working temperature|(% colspan="3" %)-10℃-60℃
106 |(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation)
107 |(% colspan="3" %)CE certification|(% colspan="3" %)Yes
108 |(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification
109 |(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A
110 |(% rowspan="7" %)(((
111 Software
112
113 function
114 )))|(% colspan="2" rowspan="4" %)(((
115 Internet of Things Services
116
117 (Optional)
118 )))|(% colspan="2" %)100 real-time data tags|300 real-time data tags
119 |(% colspan="2" %)20 alarm data tags|200 alarm data tags
120 |(% colspan="2" %)50 historical data tags|100 historical data tags
121 |(% colspan="3" %)Days of historical data saved: 60 days/1 million
122 |(% colspan="2" %)Pass through|(% colspan="3" %)Yes
123 |(% colspan="2" %)VPN Pass trough|(% colspan="3" %)Yes
124 |(% colspan="2" %)API interface|(% colspan="3" %)Yes
125
126 **1.3 Interface Description**
127 )))
128
129 ==== **(1)Appearance component description** ====
130
131 *
132 **
133 ***
134 **** **RE-00/RE-4G**
135
136 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_9ade4359.gif||height="203" width="643"]]
137
138 RE-00/RE-4G Component Description
139
140
141 |**1**|Indicator lamp|**2**|Micro-USB|**3**|Ethernet port|**4**|COM port
142 |**5**|Power supply|**6**|4G antenna (Optional)|**7**|Fixed fastener|**8**|SIM card (Optional)
143
144 *
145 **
146 ***
147 **** **RH-WF**
148
149 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_906b0210.gif||height="281" width="642"]]
150
151 RH-WF Component Description
152
153 |**1**|Indicator lamp|**2**|USB-A|**3**|Network Port 1|**4**|Network Port 2
154 |**5**|HDMI|**6**|TYPE-C|**7**|COM port|**8**|I/O interface and RS485 terminal
155 |**9**|Power supply|**10**|WIFI antenna|**11**|Fixed fastener||
156
157 ==== {{id name="_Toc24573"/}}**(2)Interface Description** ====
158
159 *
160 **
161 ***
162 **** **RE-00/RE-4G**
163
164 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d215ad34.png||height="276" width="616"]]
165
166
167 **RH-WF**
168
169 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]]
170 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="301" width="613"]]
171 \\
172
173
174 ==== {{id name="_Toc26179"/}}**(3) Interface Definition** ====
175
176 *
177 **
178 ***
179 **** **RE-00/RE-4G COM1 interface definition**
180
181 |**Pin**|**Definition**|**Pin**|**Definition**
182 |1|RS422 TX+/RS485 A+|2|RS232 RXD
183 |3|RS232 TXD|5|GND
184 |6|RS422 TX-/RS485 B-|8|RS422 RX-
185 |9|RS422 RX+||
186
187 *
188 **
189 ***
190 **** **RH-WF**
191
192 |(% colspan="2" %)**Pin**|**Definition**
193 |(% rowspan="7" %)[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ef6a7104.gif||height="205" width="93"]]|S/S|(((
194 Input mode selection terminal.
195
196 Connecting to 24V+ indicates that it supports** NPN** input;
197
198 Connecting to 24V- indicates that it supports **PNP** input.
199 )))
200 |Xn|Switch quantity input terminal
201 |Yn|Switch quantity signal output terminal, relay output
202 |COM|Output common port
203 |485+|RS485+
204 |485-|RS485-
205 |GND|Ground
206
207 == {{id name="_Toc22666"/}}{{id name="_Toc30723"/}}**2 Applications** ==
208
209 R series products,which can easily realize advanced requirements such as real-time display on industrial sites.
210
211 {{id name="_GoBack"/}}[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]]
212
213 ① Large-screen display, connect computer/TV Display the project screen;
214
215 ② Network port device, connect to network device such as slave computers, and download projects online through configuration software;
216
217 ③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software.
218
219 == {{id name="_Toc12278"/}}{{id name="_Toc1407"/}}**3 Operation Instructions** ==
220
221 === {{id name="_Toc17286"/}}{{id name="_Toc19484"/}}**3.1 Project Download-PIStudio** ===
222
223 **(1) New project**
224
225 PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
226
227 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8971673d.png||height="340" width="638"]]
228
229 **(2) Enable cloud server**
230
231 **Configuration of V-NET IoT System**
232
233 **It needs to check "Enable Cloud" function in order to view "Remote Monitoring" screen in V-NET, and configure the functions of tags, data recording on the cloud, and alarm recording on the cloud.**
234
235 Upload to the cloud: All configured tag information, historical information, and alarm information will be pushed to V-NET.
236
237
238 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_19762229.png||height="360" width="638"]]
239
240 **(3) Project compile/download**
241
242 After the project is completed, click **[Project Compile]**→After prompting that the compilation is completed, click** [Download Project]**→device detected, **[PC port]**. Ethernet or USB download→[PC→HMI]→pop up a prompt, click **[OK]** → complete the configuration project download, it will take effect after restart.
243
244 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_38834748.png||height="340" width="634"]]
245
246 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_31fafd4e.png||height="287" width="348"]]
247
248 **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
249
250 === {{id name="_Toc5083"/}}{{id name="_Toc2542"/}}**3.2 Check V-NET IoT System** ===
251
252 ==== {{id name="_Toc22900"/}}**3.2.1 V-NET login** ====
253
254 (1) New users must register first, and after the registration is successful, the user can use it.
255
256 ● A successfully registered account is an administrator account, which can bind the device and support other operations.
257
258 ● Users need to remember the registered account and password, and can log in simultaneously on the PC/APP.
259
260 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_7103ee91.png||height="274" width="453"]]
261
262 (2) Enter the account and password, and then click the **[Log in] **button.
263
264 (3) After admin account logs in to the platform, it will jump to the homepage by default, as shown in the figure below.
265
266 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
267
268 ==== {{id name="_Toc22039"/}}**3.2.2 Adding devices** ====
269
270 (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
271
272 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_45c9855a.png||height="409" width="638"]]
273
274 (2) After the **[Add Device]** window pops up, enter the device machine code and password, etc., and add the device. Other instructions are as follows:   
275
276 ① **Device machine code:** Each device has a unique and independent machine code for remote monitoring device identification.     
277
278 Obtain machine code:
279
280 ● HMI PIStudio-**[Tool]**-**[Download project]**-Machine code.
281
282 ● Scan the QR code of the device to obtain the machine code.
283
284 ② **Device password:** Refers to the cloud access password, the default is 888888. The initial binding device password: see [[Cloud Configuration>>path:mk:@MSITStore:E:%5C%5CA%E6%97%A5%E5%B8%B8%E5%B7%A5%E4%BD%9C%E6%96%87%E4%BB%B6%5C%5C2023-06-15PI%E5%B8%AE%E5%8A%A9%E6%89%8B%E5%86%8C%5C%5C%E4%B8%AD%E6%80%A7%E7%89%8820231016%EF%BC%88%E6%A0%87%E5%87%86%EF%BC%89%5C%5Chelp20231020.chm::/levi%E2%85%A1/5/5.9.htm]].
285
286 ③ **Device alias:** Refers to the name recognition of the device in the menu bar of V-NET.
287
288 (3) Binding device is successful, click OK, prompt: Bind device successful!
289
290 ==== {{id name="_Toc25660"/}}**3.2.3 V-NET check** ====
291
292 **(1) Remote monitoring**
293
294 The remote monitoring module can display the current screen in real time, and realize the operation of the project on the web page, realize the remote monitoring of the device and the control of the screen.
295
296 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a262a004.png||height="362" width="638"]]
297
298 **(2) Data viewing**
299
300 Data view has six modules, including Communication port, Collection point, Alarm configuration, Alarm record, Historical configuration, Historical data record.
301
302 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_6ce8af63.png||height="357" width="638"]]
303
304 **The specific parameter is as follows:**
305
306 ① **Communication port:** The communication port information, connection mode and protocol name configured on HMI. It can only be viewed, and cannot be added or modified. The information comes from what is set on HMI.
307
308 ② **Collection point**: Data monitoring module. The collection point is the tag, and its read-write, write-only, and read-only permissions also come from the tags set in PIStudio. (**Note: Tags cannot be added or removed here.**)
309
310 ③ **Alarm message:** For the alarm record of the device, tags cannot be added. Operations such as confirming the alarm record and exporting data can be performed.
311
312 ④ **Historical information:** The historical data of the device cannot add tag, supports curve and list viewing, and supports export historical data and other operations.
313
314 **(3) Cloud configuration**
315
316 The cloud SCADA platform is mainly used to display the monitoring/operation interface of the bound device in the V-NET.
317
318 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8ecdd915.png||height="332" width="638"]]
319
320 The main functions of Cloud SCADA interface in device management are as follows:
321
322 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_3c59fa4c.png||height="21" width="19"]] Refresh the current Cloud SCADA project.
323
324 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_56dc36ee.png||height="20" width="19"]] Browse the current Cloud SCADA project in full screen (Press “Esc” exit).
325
326 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_23075dbb.png||height="19" width="19"]] Switch the bound Cloud SCADA projects (The cloud SCADA projects bound in current device and cross-device).
327
328 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1ced925.png||height="19" width="19"]] Edit the current cloud SCADA (jump to the Cloud SCADA edit page)
329
330
331
332 **(4) Basic information**
333
334 Include: "Basic information, status push, register information, version information" for the device.
335
336 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_b1d4b150.png||height="330" width="638"]]
337
338 ●**Device name:** Mainly used to distinguish various devices.
339
340 ●**Online status**: Use the refresh function to refresh the online status of the device.
341
342 ●**Machine code:** Each device has a unique and independent machine code.
343
344 ●**Map Information:** The latitude and longitude information of the device, click “Location” to view the geographical location and modify the location information.
345
346 ●**Located with:**
347
348 ① Use device base station positioning.        
349
350 ②Use manual positioning.
351
352 Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.
353
354
355
356 == {{id name="_Toc7609"/}}{{id name="_Toc19227"/}}**3 Pass-through of device** ==
357
358 {{id name="_Toc16958"/}}{{id name="_Toc18341"/}}{{id name="_Toc10036"/}}{{id name="_Toc14306"/}}{{id name="_Toc8318"/}}{{id name="_Toc23343"/}}{{id name="_Toc11131"/}}{{id name="_Toc21238"/}}{{id name="_Toc23066"/}}{{id name="_Toc22286"/}}{{id name="_Toc32206"/}}{{id name="_Toc14201"/}}{{id name="_Toc5622"/}}{{id name="_Toc10379"/}}{{id name="_Toc29542"/}}{{id name="_Toc3580"/}}{{id name="_Toc20482"/}}{{id name="_Toc22905"/}}{{id name="_Toc10700"/}}{{id name="_Toc2060"/}}{{id name="_Toc10051"/}}**Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
359
360 Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc.
361
362 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1c4453d8.png||height="338" width="638"]]
363
364 Device status description table is as follows:
365
366 |**Color**|**Color Value (HEX)**|**Status**|**Description**
367 |●|#18E600|Online|Pass-through available
368 |●|#B5C1D8|Offline|Pass-through is not allowed
369 |●|#1C9BFD|Pass-through connecting|In pass-through
370 |●|#005CFF|VPN connecting|In pass-through
371 |●|#FD8B09|VPN pass-through is reconnecting|Pass-through reconnecting due to network and other reasons
372 |●|#2C405E|VPN pass-through is ending|The end of pass-through due to [End pass-through]
373 |●|#109A00|Download is ready.|Download channel is ready. (Download can be executed.)
374 |●|#009577|Download|In download
375
376 **Pass-through precautions:**
377
378 ● The web cannot use the pass-through function for the time being, and it needs to be in the PC client to change the location.
379
380 ● When the device is offline, “Start pass-through” cannot be clicked.
381
382 ● When the device firmware version is too low, “Start pass-through” cannot be clicked.
383
384 ● The current user does not have pass-through rights on this device or this device is shared by others, and “Start pass-through” cannot be clicked.
385
386 ● When the current user has a device in pass-through, “Start pass-through” cannot be clicked.
387
388
389
390 === {{id name="_Toc28395"/}}**4.1 Device pass-through download (RE)** ===
391
392 The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet.
393
394 **Steps:**
395
396 ① Click [[image:Wecon V-BOX R Series User Manual 240611 V1.2_f1b46bca.png||height="16" width="17"]] to enter the pass-through interface.
397
398 ② Select the device that needs pass-through, and ensure that the device is online.
399
400 ③ Click "Browse" to automatically detect the installed download tools on this machine. The table shows the versions and locations of all installed download tools. (HMI software should be installed in the computer to ensure that HMIEditor and download tools exist at the same time).
401
402 ④ Select any HMI download tool configuration in the table, and confirm the selected HMIEditor software through the folder location and corresponding version information.
403
404 ⑤ Pass-through is ready → [Start pass-through].
405
406 ●Click "Start pass-through" to conduct pass-through according to the specified download tools and selected devices.
407
408 ● Click [End pass-through] to end pass-through.
409
410 ⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program.
411
412 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
413
414 === {{id name="_Toc21457"/}}{{id name="_Toc18124"/}}**4.2 Common serial port pass-through (PLC)** ===
415
416 Based on the normal communication between RE device and PLC or other device, PLC is connected according to the generated virtual serial port, allowing the PLC software on the computer to communicate and connect with the PLC, and completing the functions of uploading/downloading PLC programs and monitoring PLC programs.
417
418 **Steps:**
419
420 ① Virtual serial port settings: Click** [Settings]** →**[Virtual Serial Port]**→**[Enable Virtual Serial Port] **→**[Select Serial Port]**. Pay attention to the serial port, please do not reuse it. (When the COM port is changed, if a PLC or other software is connecting to the original COM port, it will be disconnected.)
421
422 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_54a850e2.png||height="136" width="639"]]
423
424 ② Remote download configuration: Click [PLC pass-through ][[image:Wecon V-BOX R Series User Manual 240611 V1.2_cfc415e2.png||height="14" width="15"]] →Select the device that requires pass-through→[New/Edit]→[New Template] Configure pass-through parameters: [Name], [Communication Port], [Connection Method], [Baud Rate], [Stop Bit], [Data Bit], [Check Bit], the configured parameters need to be consistent with the PLC serial port parameters →[OK]→Prompt "Add successfully!"→[OK].
425
426 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_353545eb.png||height="339" width="638"]]
427
428 ③ Pass-through steps: On the pass-through interface, click [Start pass-through]→after successful pass-through, it will prompt "pass-through succeeded"→[OK].
429
430 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_5b5ad7dd.png||height="339" width="638"]]
431
432 ④ After the pass-through is successful, the indicator light of the corresponding RE device on the PC will turn blue, and the [current status] will become pass-through, indicating that the device is in the "pass-through" status.
433
434 ✎**Note:** Do not click [End pass-through], otherwise you will exit the pass-through function.
435
436
437
438 {{id name="_Toc14659"/}}{{id name="_Toc5468"/}}{{id name="_Toc29362"/}}⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored.
439
440 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]]
441
442 {{id name="_Toc24528"/}}{{id name="_Toc6595"/}}{{id name="_Toc20246"/}}**Pass-through Precautions:**
443
444 ① In the process of PLC software remote access, the pass-through serial port of the RE device needs to maintain a normal communication state, and the network state needs to remain stable.
445
446 ② When the device is in the pass-through, COM indicator light will be in the off status. When the device ends the pass-through, it will automatically restart.
447
448 ③ The parameters of the PLC connection need to be consistent with the parameters generated by the virtual serial port.
449
450 ④ It is necessary to ensure that the PLC serial port of pass-through can support the upload/download function, otherwise the remote pass-through function cannot be realized.
451
452 === {{id name="_Toc21835"/}}**4.3 VPN pass-through (PLC)** ===
453
454 **VPN pass-through:** The pass-through function allows the application program on the computer to directly control the PLC device through the RE device, upload/download PLC programs, monitor PLC programs or other configuration information, etc.
455
456 **Steps:**
457
458 ① Click [VPN pass-through][[image:Wecon V-BOX R Series User Manual 240611 V1.2_74d5c70b.png||height="14" width="15"]] →Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK].
459
460 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]]
461
462 ② After pass-through is successful, the indicator light of the corresponding RE device on the PC will turn yellow, and [current status] will become in the VPN pass-through, indicating that the device is in the "pass-through" status. (**Note:** You cannot click [End pass-through], otherwise you will exit the pass-through.)
463
464 ③ After the pass-through is successful, a virtual network card will be generated. You can check whether the IP is generated through the network card of the computer, as shown below.
465
466 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a53a8121.png||height="336" width="638"]]
467
468 ④ When PLC software completes the remote operation, select [End pass-through]→Prompt "End VPN pass through successfully"→[OK], at this time the device will automatically restart, and after the restart is completed, the working status before pass-through will be restored.
469
470 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_40416c98.png||height="336" width="638"]]
471
472 **Pass-through precautions:**
473
474 ① The Ethernet port IP of RE device, the IP used by the VPN pass-through, and the IP of the PLC must be kept in the same network segment without conflict.
475
476 ② The IP connected to the PLC needs to be consistent with the IP of the PLC itself.
477
478 ③ When the device ends the pass-through function, RE device will automatically restart.
479
480 ④ If the VPN pass-through is unsuccessful, please refer to the "Frequently Asked Questions of Wecon VPN pass-through Tools" for troubleshooting.
481
482 The file path is as follows:
483
484 https:~/~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526 **Wecon Technology Co., Ltd 
527 Factory Address: 10th Building, Area E, Fuzhou Software Park, Gulou District, Fuzhou, Fujian Province, P.R.China
528 R&D Center: Floor 5-7, Block 6, Area F, Fuzhou Software Park, Gulou District, Fuzhou, Fujian, Province, P.R. China
529 Tel: +86-591-87868869 Fax: +86-591-87843899
530 Website: www.we-con.com.con/en
531 Email: sales@we-con.com.cn**