Wiki source code of 1 Product description

Version 41.2 by Mora Zhou on 2024/08/12 15:08

Show last authors
1 **Wecon V-BOX R Series User Manual**
2
3 == **1 Product description** ==
4
5 |**Series**|**Model**|**Description**
6 |(% rowspan="3" %)**R Series**|RE-00|1 network port, single serial port
7 |RE-4G|1 network port, single serial port, support 4G.
8 |RH-WF|(((
9 2 network ports, 1 HDMI interface, single serial port, 2 RS485 terminals, support WiFi
10
11 2 optocoupler isolated input (DI), 2relay output (DO)
12 )))
13
14 === **1.1 Product appearance** ===
15
16 ==== **(1)RE-00/RE-4G** ====
17
18 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_eae14981.png||height="305" width="273"]]
19
20 RE-00/RE-4G Appearance
21
22 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59f1285c.gif||height="259" width="643"]]
23
24 RE-00/RE-4G Installation Dimensions
25
26 ==== {{id name="_Toc15014"/}}**(2) RH-WF** ====
27
28 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]]
29
30 (((
31 **WiFi antenna**
32 )))
33
34 RH-WF
35
36 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]]
37
38 {{id name="_Toc7941"/}}Installation Size
39
40
41
42
43
44
45 === {{id name="_Toc7987"/}}**1.2 Product specifications** ===
46
47 === {{id name="_Toc16174"/}}{{id name="_Toc12326"/}} ===
48
49 (((
50 |(% colspan="3" %)**Model/Specifications**|**RE-00**|**RE-4G**|**RH-WF**
51 |(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters**
52 |(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz
53 |(% rowspan="3" %)Memory|(% colspan="2" %)Flash|(% colspan="2" %)128MB|8GB
54 |(% colspan="2" %)RAM|(% colspan="2" %)DDRII 64MB|2GB
55 |(% colspan="2" %)SD Card|(% colspan="2" %)N/A|TF card
56 |(% rowspan="8" %)(((
57 I/O
58
59 Interface
60 )))|(% colspan="2" %)USB HOST|(% colspan="2" %)1, no isolation|(((
61 USB 2.0*1 No isolation
62
63 USB 3.0*1 No isolation
64 )))
65 |(% colspan="2" %)USB DEVICE|(% colspan="2" %)1, no isolation|Type-C*1
66 |(% colspan="2" %)Serial port|(% colspan="2" %)COM1: RS232, RS422/RS485|(((
67 COM1: RS232, RS422/RS485 (2 in 1)
68
69 1 expansion serial port (terminal line)
70
71 [COM2: RS485]
72 )))
73 |(% colspan="2" %)Ethernet port|(% colspan="2" %)1|10/100M Interface*2
74 |(% colspan="2" %)WIFI module|(% colspan="2" %)N/A|Yes
75 |(% colspan="2" %)4G module|N/A|4G|N/A
76 |(% colspan="2" %)HDMI|(% colspan="2" %)N/A|HDMI 2.0*1
77 |(% colspan="2" %)I/O|(% colspan="2" %)N/A|2-channel relay output, 2-channel isolated input with optocoupler
78 |(% rowspan="2" %)Power supply|(% colspan="2" %)Input power supply|(% colspan="3" %)24V DC (12-28V DC)
79 |(% colspan="2" %)Power consumption|(% colspan="3" %)<10W
80 |(% rowspan="4" %)Specifications|(% colspan="2" %)Shell material|(% colspan="2" %)Cold rolled sheet|Engineering-plastics PC+AB5 (Flame retardant level)
81 |(% colspan="2" %)Dimensions (W*H*D)|(% colspan="2" %)101.0*73.2*26.8mm|125.0*93.7*51.0 mm
82 |(% colspan="2" %)Wall mounting hole dimensions|(% colspan="2" %)110.0*15.6 mm|/(Fastener mounting)
83 |(% colspan="2" %)Weight|(% colspan="2" %)0.26Kg|253g
84 |(% rowspan="4" %)(((
85 Operation
86
87 Environment
88 )))|(% colspan="2" %)Vibration resistance|(% colspan="3" %)Compile with IEC61131-2 standard
89 |(% colspan="2" %)Storage temperature|(% colspan="3" %)-20℃-70℃
90 |(% colspan="2" %)Working temperature|(% colspan="3" %)-10℃-60℃
91 |(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation)
92 |(% colspan="3" %)CE certification|(% colspan="3" %)Yes
93 |(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification
94 |(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A
95 |(% rowspan="7" %)(((
96 Software
97
98 function
99 )))|(% colspan="2" rowspan="4" %)(((
100 Internet of Things Services
101
102 (Optional)
103 )))|(% colspan="2" %)100 real-time data tags|300 real-time data tags
104 |(% colspan="2" %)20 alarm data tags|200 alarm data tags
105 |(% colspan="2" %)50 historical data tags|100 historical data tags
106 |(% colspan="3" %)Days of historical data saved: 60 days/1 million
107 |(% colspan="2" %)Pass through|(% colspan="3" %)Yes
108 |(% colspan="2" %)VPN Pass trough|(% colspan="3" %)Yes
109 |(% colspan="2" %)API interface|(% colspan="3" %)Yes
110
111 **1.3 Interface Description**
112 )))
113
114 ==== **(1)Appearance component description** ====
115
116 *
117 **
118 ***
119 **** **RE-00/RE-4G**
120
121 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_9ade4359.gif||height="203" width="643"]]
122
123 RE-00/RE-4G Component Description
124
125
126 |**1**|Indicator lamp|**2**|Micro-USB|**3**|Ethernet port|**4**|COM port
127 |**5**|Power supply|**6**|4G antenna (Optional)|**7**|Fixed fastener|**8**|SIM card (Optional)
128
129 *
130 **
131 ***
132 **** **RH-WF**
133
134 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_906b0210.gif||height="281" width="642"]]
135
136 RH-WF Component Description
137
138 |**1**|Indicator lamp|**2**|USB-A|**3**|Network Port 1|**4**|Network Port 2
139 |**5**|HDMI|**6**|TYPE-C|**7**|COM port|**8**|I/O interface and RS485 terminal
140 |**9**|Power supply|**10**|WIFI antenna|**11**|Fixed fastener| |
141
142 ==== {{id name="_Toc24573"/}}**(2)Interface Description** ====
143
144 *
145 **
146 ***
147 **** **RE-00/RE-4G**
148
149 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d215ad34.png||height="276" width="616"]]
150
151
152 **RH-WF**
153
154 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]]
155 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="301" width="613"]]
156
157
158
159 ==== {{id name="_Toc26179"/}}**(3) Interface Definition** ====
160
161 *
162 **
163 ***
164 **** **RE-00/RE-4G COM1 interface definition**
165
166 |**Pin**|**Definition**|**Pin**|**Definition**
167 |1|RS422 TX+/RS485 A+|2|RS232 RXD
168 |3|RS232 TXD|5|GND
169 |6|RS422 TX-/RS485 B-|8|RS422 RX-
170 |9|RS422 RX+| |
171
172 *
173 **
174 ***
175 **** **RH-WF**
176
177 |(% colspan="2" %)**Pin**|**Definition**
178 |(% rowspan="7" %)[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ef6a7104.gif||height="205" width="93"]]|S/S|(((
179 Input mode selection terminal.
180
181 Connecting to 24V+ indicates that it supports** NPN** input;
182
183 Connecting to 24V- indicates that it supports **PNP** input.
184 )))
185 |Xn|Switch quantity input terminal
186 |Yn|Switch quantity signal output terminal, relay output
187 |COM|Output common port
188 |485+|RS485+
189 |485-|RS485-
190 |GND|Ground
191
192 == {{id name="_Toc22666"/}}{{id name="_Toc30723"/}}**2 Applications** ==
193
194 R series products,which can easily realize advanced requirements such as real-time display on industrial sites.
195
196 {{id name="_GoBack"/}}[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]]
197
198 ① Large-screen display, connect computer/TV Display the project screen;
199
200 ② Network port device, connect to network device such as slave computers, and download projects online through configuration software;
201
202 ③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software.
203
204 == {{id name="_Toc12278"/}}{{id name="_Toc1407"/}}**3 Operation Instructions** ==
205
206 === {{id name="_Toc17286"/}}{{id name="_Toc19484"/}}**3.1 Project Download-PIStudio** ===
207
208 **(1) New project**
209
210 PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
211
212 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8971673d.png||height="340" width="638"]]
213
214 **(2) Enable cloud server**
215
216 **Configuration of V-NET IoT System**
217
218 **It needs to check "Enable Cloud" function in order to view "Remote Monitoring" screen in V-NET, and configure the functions of tags, data recording on the cloud, and alarm recording on the cloud.**
219
220 Upload to the cloud: All configured tag information, historical information, and alarm information will be pushed to V-NET.
221
222
223 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_19762229.png||height="360" width="638"]]
224
225 **(3) Project compile/download**
226
227 After the project is completed, click **[Project Compile]**→After prompting that the compilation is completed, click** [Download Project]**→device detected, **[PC port]**. Ethernet or USB download→[PC→HMI]→pop up a prompt, click **[OK]** → complete the configuration project download, it will take effect after restart.
228
229 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_38834748.png||height="340" width="634"]]
230
231 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_31fafd4e.png||height="287" width="348"]]
232
233 **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
234
235 === {{id name="_Toc5083"/}}{{id name="_Toc2542"/}}**3.2 Check V-NET IoT System** ===
236
237 ==== {{id name="_Toc22900"/}}**3.2.1 V-NET login** ====
238
239 (1) New users must register first, and after the registration is successful, the user can use it.
240
241 ● A successfully registered account is an administrator account, which can bind the device and support other operations.
242
243 ● Users need to remember the registered account and password, and can log in simultaneously on the PC/APP.
244
245 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_7103ee91.png||height="274" width="453"]]
246
247 (2) Enter the account and password, and then click the **[Log in] **button.
248
249 (3) After admin account logs in to the platform, it will jump to the homepage by default, as shown in the figure below.
250
251 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
252
253 ==== {{id name="_Toc22039"/}}**3.2.2 Adding devices** ====
254
255 (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
256
257 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_45c9855a.png||height="409" width="638"]]
258
259 (2) After the **[Add Device]** window pops up, enter the device machine code and password, etc., and add the device. Other instructions are as follows:   
260
261 ① **Device machine code:** Each device has a unique and independent machine code for remote monitoring device identification.     
262
263 Obtain machine code:
264
265 ● HMI PIStudio-**[Tool]**-**[Download project]**-Machine code.
266
267 ● Scan the QR code of the device to obtain the machine code.
268
269 ② **Device password:** Refers to the cloud access password, the default is 888888. The initial binding device password: see [[Cloud Configuration>>path:mk:@MSITStore:E:%5C%5CA%E6%97%A5%E5%B8%B8%E5%B7%A5%E4%BD%9C%E6%96%87%E4%BB%B6%5C%5C2023-06-15PI%E5%B8%AE%E5%8A%A9%E6%89%8B%E5%86%8C%5C%5C%E4%B8%AD%E6%80%A7%E7%89%8820231016%EF%BC%88%E6%A0%87%E5%87%86%EF%BC%89%5C%5Chelp20231020.chm::/levi%E2%85%A1/5/5.9.htm]].
270
271 ③ **Device alias:** Refers to the name recognition of the device in the menu bar of V-NET.
272
273 (3) Binding device is successful, click OK, prompt: Bind device successful!
274
275 ==== {{id name="_Toc25660"/}}**3.2.3 V-NET check** ====
276
277 **(1) Remote monitoring**
278
279 The remote monitoring module can display the current screen in real time, and realize the operation of the project on the web page, realize the remote monitoring of the device and the control of the screen.
280
281 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a262a004.png||height="362" width="638"]]
282
283 **(2) Data viewing**
284
285 Data view has six modules, including Communication port, Collection point, Alarm configuration, Alarm record, Historical configuration, Historical data record.
286
287 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_6ce8af63.png||height="357" width="638"]]
288
289 **The specific parameter is as follows:**
290
291 ① **Communication port:** The communication port information, connection mode and protocol name configured on HMI. It can only be viewed, and cannot be added or modified. The information comes from what is set on HMI.
292
293 ② **Collection point**: Data monitoring module. The collection point is the tag, and its read-write, write-only, and read-only permissions also come from the tags set in PIStudio. (**Note: Tags cannot be added or removed here.**)
294
295 ③ **Alarm message:** For the alarm record of the device, tags cannot be added. Operations such as confirming the alarm record and exporting data can be performed.
296
297 ④ **Historical information:** The historical data of the device cannot add tag, supports curve and list viewing, and supports export historical data and other operations.
298
299 **(3) Cloud configuration**
300
301 The cloud SCADA platform is mainly used to display the monitoring/operation interface of the bound device in the V-NET.
302
303 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8ecdd915.png||height="332" width="638"]]
304
305 The main functions of Cloud SCADA interface in device management are as follows:
306
307 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_3c59fa4c.png||height="21" width="19"]] Refresh the current Cloud SCADA project.
308
309 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_56dc36ee.png||height="20" width="19"]] Browse the current Cloud SCADA project in full screen (Press “Esc” exit).
310
311 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_23075dbb.png||height="19" width="19"]] Switch the bound Cloud SCADA projects (The cloud SCADA projects bound in current device and cross-device).
312
313 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1ced925.png||height="19" width="19"]] Edit the current cloud SCADA (jump to the Cloud SCADA edit page)
314
315
316 **(4) Basic information**
317
318 Include: "Basic information, status push, register information, version information" for the device.
319
320 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_b1d4b150.png||height="330" width="638"]]
321
322 ●**Device name:** Mainly used to distinguish various devices.
323
324 ●**Online status**: Use the refresh function to refresh the online status of the device.
325
326 ●**Machine code:** Each device has a unique and independent machine code.
327
328 ●**Map Information:** The latitude and longitude information of the device, click “Location” to view the geographical location and modify the location information.
329
330 ●**Located with:**
331
332 ① Use device base station positioning.        
333
334 ②Use manual positioning.
335
336 Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.
337
338
339 == {{id name="_Toc7609"/}}{{id name="_Toc19227"/}}**3 Pass-through of device** ==
340
341 {{id name="_Toc16958"/}}{{id name="_Toc18341"/}}{{id name="_Toc10036"/}}{{id name="_Toc14306"/}}{{id name="_Toc8318"/}}{{id name="_Toc23343"/}}{{id name="_Toc11131"/}}{{id name="_Toc21238"/}}{{id name="_Toc23066"/}}{{id name="_Toc22286"/}}{{id name="_Toc32206"/}}{{id name="_Toc14201"/}}{{id name="_Toc5622"/}}{{id name="_Toc10379"/}}{{id name="_Toc29542"/}}{{id name="_Toc3580"/}}{{id name="_Toc20482"/}}{{id name="_Toc22905"/}}{{id name="_Toc10700"/}}{{id name="_Toc2060"/}}{{id name="_Toc10051"/}}**Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
342
343 Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc.
344
345 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1c4453d8.png||height="338" width="638"]]
346
347 Device status description table is as follows:
348
349 |**Color**|**Color Value (HEX)**|**Status**|**Description**
350 |●|#18E600|Online|Pass-through available
351 |●|#B5C1D8|Offline|Pass-through is not allowed
352 |●|#1C9BFD|Pass-through connecting|In pass-through
353 |●|#005CFF|VPN connecting|In pass-through
354 |●|#FD8B09|VPN pass-through is reconnecting|Pass-through reconnecting due to network and other reasons
355 |●|#2C405E|VPN pass-through is ending|The end of pass-through due to [End pass-through]
356 |●|#109A00|Download is ready.|Download channel is ready. (Download can be executed.)
357 |●|#009577|Download|In download
358
359 **Pass-through precautions:**
360
361 ● The web cannot use the pass-through function for the time being, and it needs to be in the PC client to change the location.
362
363 ● When the device is offline, “Start pass-through” cannot be clicked.
364
365 ● When the device firmware version is too low, “Start pass-through” cannot be clicked.
366
367 ● The current user does not have pass-through rights on this device or this device is shared by others, and “Start pass-through” cannot be clicked.
368
369 ● When the current user has a device in pass-through, “Start pass-through” cannot be clicked.
370
371
372 === {{id name="_Toc28395"/}}**4.1 Device pass-through download (RE)** ===
373
374 The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet.
375
376 **Steps:**
377
378 ① Click [[image:Wecon V-BOX R Series User Manual 240611 V1.2_f1b46bca.png||height="16" width="17"]] to enter the pass-through interface.
379
380 ② Select the device that needs pass-through, and ensure that the device is online.
381
382 ③ Click "Browse" to automatically detect the installed download tools on this machine. The table shows the versions and locations of all installed download tools. (HMI software should be installed in the computer to ensure that HMIEditor and download tools exist at the same time).
383
384 ④ Select any HMI download tool configuration in the table, and confirm the selected HMIEditor software through the folder location and corresponding version information.
385
386 ⑤ Pass-through is ready → [Start pass-through].
387
388 ●Click "Start pass-through" to conduct pass-through according to the specified download tools and selected devices.
389
390 ● Click [End pass-through] to end pass-through.
391
392 ⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program.
393
394 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
395
396 === {{id name="_Toc21457"/}}{{id name="_Toc18124"/}}**4.2 Common serial port pass-through (PLC)** ===
397
398 Based on the normal communication between RE device and PLC or other device, PLC is connected according to the generated virtual serial port, allowing the PLC software on the computer to communicate and connect with the PLC, and completing the functions of uploading/downloading PLC programs and monitoring PLC programs.
399
400 **Steps:**
401
402 ① Virtual serial port settings: Click** [Settings]** →**[Virtual Serial Port]**→**[Enable Virtual Serial Port] **→**[Select Serial Port]**. Pay attention to the serial port, please do not reuse it. (When the COM port is changed, if a PLC or other software is connecting to the original COM port, it will be disconnected.)
403
404 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_54a850e2.png||height="136" width="639"]]
405
406 ② Remote download configuration: Click [PLC pass-through ][[image:Wecon V-BOX R Series User Manual 240611 V1.2_cfc415e2.png||height="14" width="15"]] →Select the device that requires pass-through→[New/Edit]→[New Template] Configure pass-through parameters: [Name], [Communication Port], [Connection Method], [Baud Rate], [Stop Bit], [Data Bit], [Check Bit], the configured parameters need to be consistent with the PLC serial port parameters →[OK]→Prompt "Add successfully!"→[OK].
407
408 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_353545eb.png||height="339" width="638"]]
409
410 ③ Pass-through steps: On the pass-through interface, click [Start pass-through]→after successful pass-through, it will prompt "pass-through succeeded"→[OK].
411
412 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_5b5ad7dd.png||height="339" width="638"]]
413
414 ④ After the pass-through is successful, the indicator light of the corresponding RE device on the PC will turn blue, and the [current status] will become pass-through, indicating that the device is in the "pass-through" status.
415
416 ✎**Note:** Do not click [End pass-through], otherwise you will exit the pass-through function.
417
418
419
420 {{id name="_Toc14659"/}}{{id name="_Toc5468"/}}{{id name="_Toc29362"/}}⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored.
421
422 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]]
423
424 {{id name="_Toc24528"/}}{{id name="_Toc6595"/}}{{id name="_Toc20246"/}}**Pass-through Precautions:**
425
426 ① In the process of PLC software remote access, the pass-through serial port of the RE device needs to maintain a normal communication state, and the network state needs to remain stable.
427
428 ② When the device is in the pass-through, COM indicator light will be in the off status. When the device ends the pass-through, it will automatically restart.
429
430 ③ The parameters of the PLC connection need to be consistent with the parameters generated by the virtual serial port.
431
432 ④ It is necessary to ensure that the PLC serial port of pass-through can support the upload/download function, otherwise the remote pass-through function cannot be realized.
433
434 === {{id name="_Toc21835"/}}**4.3 VPN pass-through (PLC)** ===
435
436 **VPN pass-through:** The pass-through function allows the application program on the computer to directly control the PLC device through the RE device, upload/download PLC programs, monitor PLC programs or other configuration information, etc.
437
438 **Steps:**
439
440 ① Click [VPN pass-through][[image:Wecon V-BOX R Series User Manual 240611 V1.2_74d5c70b.png||height="14" width="15"]] →Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK].
441
442 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]]
443
444 ② After pass-through is successful, the indicator light of the corresponding RE device on the PC will turn yellow, and [current status] will become in the VPN pass-through, indicating that the device is in the "pass-through" status. (**Note:** You cannot click [End pass-through], otherwise you will exit the pass-through.)
445
446 ③ After the pass-through is successful, a virtual network card will be generated. You can check whether the IP is generated through the network card of the computer, as shown below.
447
448 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a53a8121.png||height="336" width="638"]]
449
450 ④ When PLC software completes the remote operation, select [End pass-through]→Prompt "End VPN pass through successfully"→[OK], at this time the device will automatically restart, and after the restart is completed, the working status before pass-through will be restored.
451
452 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_40416c98.png||height="336" width="638"]]
453
454 **Pass-through precautions:**
455
456 ① The Ethernet port IP of RE device, the IP used by the VPN pass-through, and the IP of the PLC must be kept in the same network segment without conflict.
457
458 ② The IP connected to the PLC needs to be consistent with the IP of the PLC itself.
459
460 ③ When the device ends the pass-through function, RE device will automatically restart.
461
462 ④ If the VPN pass-through is unsuccessful, please refer to the "Frequently Asked Questions of Wecon VPN pass-through Tools" for troubleshooting.
463
464 The file path is as follows:
465
466 https:~/~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508 **Wecon Technology Co., Ltd 
509 Factory Address: 10th Building, Area E, Fuzhou Software Park, Gulou District, Fuzhou, Fujian Province, P.R.China
510 R&D Center: Floor 5-7, Block 6, Area F, Fuzhou Software Park, Gulou District, Fuzhou, Fujian, Province, P.R. China