Wiki source code of 1 Product description

Version 41.3 by Mora Zhou on 2024/08/12 15:09

Show last authors
1 **Wecon V-BOX R Series User Manual**
2
3 == **1 Product description** ==
4
5 |**Series**|**Model**|**Description**
6 |(% rowspan="3" %)**R Series**|RE-00|1 network port, single serial port
7 |RE-4G|1 network port, single serial port, support 4G.
8 |RH-WF|(((
9 2 network ports, 1 HDMI interface, single serial port, 2 RS485 terminals, support WiFi
10
11 2 optocoupler isolated input (DI), 2relay output (DO)
12 )))
13
14 === **1.1 Product appearance** ===
15
16 ==== **(1)RE-00/RE-4G** ====
17
18 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_eae14981.png||height="305" width="273"]]
19
20 RE-00/RE-4G Appearance
21
22 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59f1285c.gif||height="259" width="643"]]
23
24 RE-00/RE-4G Installation Dimensions
25
26 ==== **(2) RH-WF** ====
27
28 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]]
29
30 (((
31 **WiFi antenna**
32 )))
33
34 RH-WF
35
36 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]]
37
38 Installation Size
39
40
41
42
43
44
45 === **1.2 Product specifications** ===
46
47 (((
48 |(% colspan="3" %)**Model/Specifications**|**RE-00**|**RE-4G**|**RH-WF**
49 |(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters**
50 |(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz
51 |(% rowspan="3" %)Memory|(% colspan="2" %)Flash|(% colspan="2" %)128MB|8GB
52 |(% colspan="2" %)RAM|(% colspan="2" %)DDRII 64MB|2GB
53 |(% colspan="2" %)SD Card|(% colspan="2" %)N/A|TF card
54 |(% rowspan="8" %)(((
55 I/O
56
57 Interface
58 )))|(% colspan="2" %)USB HOST|(% colspan="2" %)1, no isolation|(((
59 USB 2.0*1 No isolation
60
61 USB 3.0*1 No isolation
62 )))
63 |(% colspan="2" %)USB DEVICE|(% colspan="2" %)1, no isolation|Type-C*1
64 |(% colspan="2" %)Serial port|(% colspan="2" %)COM1: RS232, RS422/RS485|(((
65 COM1: RS232, RS422/RS485 (2 in 1)
66
67 1 expansion serial port (terminal line)
68
69 [COM2: RS485]
70 )))
71 |(% colspan="2" %)Ethernet port|(% colspan="2" %)1|10/100M Interface*2
72 |(% colspan="2" %)WIFI module|(% colspan="2" %)N/A|Yes
73 |(% colspan="2" %)4G module|N/A|4G|N/A
74 |(% colspan="2" %)HDMI|(% colspan="2" %)N/A|HDMI 2.0*1
75 |(% colspan="2" %)I/O|(% colspan="2" %)N/A|2-channel relay output, 2-channel isolated input with optocoupler
76 |(% rowspan="2" %)Power supply|(% colspan="2" %)Input power supply|(% colspan="3" %)24V DC (12-28V DC)
77 |(% colspan="2" %)Power consumption|(% colspan="3" %)<10W
78 |(% rowspan="4" %)Specifications|(% colspan="2" %)Shell material|(% colspan="2" %)Cold rolled sheet|Engineering-plastics PC+AB5 (Flame retardant level)
79 |(% colspan="2" %)Dimensions (W*H*D)|(% colspan="2" %)101.0*73.2*26.8mm|125.0*93.7*51.0 mm
80 |(% colspan="2" %)Wall mounting hole dimensions|(% colspan="2" %)110.0*15.6 mm|/(Fastener mounting)
81 |(% colspan="2" %)Weight|(% colspan="2" %)0.26Kg|253g
82 |(% rowspan="4" %)(((
83 Operation
84
85 Environment
86 )))|(% colspan="2" %)Vibration resistance|(% colspan="3" %)Compile with IEC61131-2 standard
87 |(% colspan="2" %)Storage temperature|(% colspan="3" %)-20℃-70℃
88 |(% colspan="2" %)Working temperature|(% colspan="3" %)-10℃-60℃
89 |(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation)
90 |(% colspan="3" %)CE certification|(% colspan="3" %)Yes
91 |(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification
92 |(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A
93 |(% rowspan="7" %)(((
94 Software
95
96 function
97 )))|(% colspan="2" rowspan="4" %)(((
98 Internet of Things Services
99
100 (Optional)
101 )))|(% colspan="2" %)100 real-time data tags|300 real-time data tags
102 |(% colspan="2" %)20 alarm data tags|200 alarm data tags
103 |(% colspan="2" %)50 historical data tags|100 historical data tags
104 |(% colspan="3" %)Days of historical data saved: 60 days/1 million
105 |(% colspan="2" %)Pass through|(% colspan="3" %)Yes
106 |(% colspan="2" %)VPN Pass trough|(% colspan="3" %)Yes
107 |(% colspan="2" %)API interface|(% colspan="3" %)Yes
108
109 **1.3 Interface Description**
110 )))
111
112 ==== **(1)Appearance component description** ====
113
114 *
115 **
116 ***
117 **** **RE-00/RE-4G**
118
119 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_9ade4359.gif||height="203" width="643"]]
120
121 RE-00/RE-4G Component Description
122
123
124 |**1**|Indicator lamp|**2**|Micro-USB|**3**|Ethernet port|**4**|COM port
125 |**5**|Power supply|**6**|4G antenna (Optional)|**7**|Fixed fastener|**8**|SIM card (Optional)
126
127 *
128 **
129 ***
130 **** **RH-WF**
131
132 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_906b0210.gif||height="281" width="642"]]
133
134 RH-WF Component Description
135
136 |**1**|Indicator lamp|**2**|USB-A|**3**|Network Port 1|**4**|Network Port 2
137 |**5**|HDMI|**6**|TYPE-C|**7**|COM port|**8**|I/O interface and RS485 terminal
138 |**9**|Power supply|**10**|WIFI antenna|**11**|Fixed fastener| |
139
140 ==== {{id name="_Toc24573"/}}**(2)Interface Description** ====
141
142 *
143 **
144 ***
145 **** **RE-00/RE-4G**
146
147 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d215ad34.png||height="276" width="616"]]
148
149
150 **RH-WF**
151
152 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]]
153 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="301" width="613"]]
154
155
156
157 ==== {{id name="_Toc26179"/}}**(3) Interface Definition** ====
158
159 *
160 **
161 ***
162 **** **RE-00/RE-4G COM1 interface definition**
163
164 |**Pin**|**Definition**|**Pin**|**Definition**
165 |1|RS422 TX+/RS485 A+|2|RS232 RXD
166 |3|RS232 TXD|5|GND
167 |6|RS422 TX-/RS485 B-|8|RS422 RX-
168 |9|RS422 RX+| |
169
170 *
171 **
172 ***
173 **** **RH-WF**
174
175 |(% colspan="2" %)**Pin**|**Definition**
176 |(% rowspan="7" %)[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ef6a7104.gif||height="205" width="93"]]|S/S|(((
177 Input mode selection terminal.
178
179 Connecting to 24V+ indicates that it supports** NPN** input;
180
181 Connecting to 24V- indicates that it supports **PNP** input.
182 )))
183 |Xn|Switch quantity input terminal
184 |Yn|Switch quantity signal output terminal, relay output
185 |COM|Output common port
186 |485+|RS485+
187 |485-|RS485-
188 |GND|Ground
189
190 == {{id name="_Toc22666"/}}{{id name="_Toc30723"/}}**2 Applications** ==
191
192 R series products,which can easily realize advanced requirements such as real-time display on industrial sites.
193
194 {{id name="_GoBack"/}}[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]]
195
196 ① Large-screen display, connect computer/TV Display the project screen;
197
198 ② Network port device, connect to network device such as slave computers, and download projects online through configuration software;
199
200 ③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software.
201
202 == {{id name="_Toc12278"/}}{{id name="_Toc1407"/}}**3 Operation Instructions** ==
203
204 === {{id name="_Toc17286"/}}{{id name="_Toc19484"/}}**3.1 Project Download-PIStudio** ===
205
206 **(1) New project**
207
208 PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
209
210 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8971673d.png||height="340" width="638"]]
211
212 **(2) Enable cloud server**
213
214 **Configuration of V-NET IoT System**
215
216 **It needs to check "Enable Cloud" function in order to view "Remote Monitoring" screen in V-NET, and configure the functions of tags, data recording on the cloud, and alarm recording on the cloud.**
217
218 Upload to the cloud: All configured tag information, historical information, and alarm information will be pushed to V-NET.
219
220
221 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_19762229.png||height="360" width="638"]]
222
223 **(3) Project compile/download**
224
225 After the project is completed, click **[Project Compile]**→After prompting that the compilation is completed, click** [Download Project]**→device detected, **[PC port]**. Ethernet or USB download→[PC→HMI]→pop up a prompt, click **[OK]** → complete the configuration project download, it will take effect after restart.
226
227 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_38834748.png||height="340" width="634"]]
228
229 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_31fafd4e.png||height="287" width="348"]]
230
231 **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
232
233 === {{id name="_Toc5083"/}}{{id name="_Toc2542"/}}**3.2 Check V-NET IoT System** ===
234
235 ==== {{id name="_Toc22900"/}}**3.2.1 V-NET login** ====
236
237 (1) New users must register first, and after the registration is successful, the user can use it.
238
239 ● A successfully registered account is an administrator account, which can bind the device and support other operations.
240
241 ● Users need to remember the registered account and password, and can log in simultaneously on the PC/APP.
242
243 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_7103ee91.png||height="274" width="453"]]
244
245 (2) Enter the account and password, and then click the **[Log in] **button.
246
247 (3) After admin account logs in to the platform, it will jump to the homepage by default, as shown in the figure below.
248
249 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
250
251 ==== {{id name="_Toc22039"/}}**3.2.2 Adding devices** ====
252
253 (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
254
255 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_45c9855a.png||height="409" width="638"]]
256
257 (2) After the **[Add Device]** window pops up, enter the device machine code and password, etc., and add the device. Other instructions are as follows:   
258
259 ① **Device machine code:** Each device has a unique and independent machine code for remote monitoring device identification.     
260
261 Obtain machine code:
262
263 ● HMI PIStudio-**[Tool]**-**[Download project]**-Machine code.
264
265 ● Scan the QR code of the device to obtain the machine code.
266
267 ② **Device password:** Refers to the cloud access password, the default is 888888. The initial binding device password: see [[Cloud Configuration>>path:mk:@MSITStore:E:%5C%5CA%E6%97%A5%E5%B8%B8%E5%B7%A5%E4%BD%9C%E6%96%87%E4%BB%B6%5C%5C2023-06-15PI%E5%B8%AE%E5%8A%A9%E6%89%8B%E5%86%8C%5C%5C%E4%B8%AD%E6%80%A7%E7%89%8820231016%EF%BC%88%E6%A0%87%E5%87%86%EF%BC%89%5C%5Chelp20231020.chm::/levi%E2%85%A1/5/5.9.htm]].
268
269 ③ **Device alias:** Refers to the name recognition of the device in the menu bar of V-NET.
270
271 (3) Binding device is successful, click OK, prompt: Bind device successful!
272
273 ==== {{id name="_Toc25660"/}}**3.2.3 V-NET check** ====
274
275 **(1) Remote monitoring**
276
277 The remote monitoring module can display the current screen in real time, and realize the operation of the project on the web page, realize the remote monitoring of the device and the control of the screen.
278
279 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a262a004.png||height="362" width="638"]]
280
281 **(2) Data viewing**
282
283 Data view has six modules, including Communication port, Collection point, Alarm configuration, Alarm record, Historical configuration, Historical data record.
284
285 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_6ce8af63.png||height="357" width="638"]]
286
287 **The specific parameter is as follows:**
288
289 ① **Communication port:** The communication port information, connection mode and protocol name configured on HMI. It can only be viewed, and cannot be added or modified. The information comes from what is set on HMI.
290
291 ② **Collection point**: Data monitoring module. The collection point is the tag, and its read-write, write-only, and read-only permissions also come from the tags set in PIStudio. (**Note: Tags cannot be added or removed here.**)
292
293 ③ **Alarm message:** For the alarm record of the device, tags cannot be added. Operations such as confirming the alarm record and exporting data can be performed.
294
295 ④ **Historical information:** The historical data of the device cannot add tag, supports curve and list viewing, and supports export historical data and other operations.
296
297 **(3) Cloud configuration**
298
299 The cloud SCADA platform is mainly used to display the monitoring/operation interface of the bound device in the V-NET.
300
301 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8ecdd915.png||height="332" width="638"]]
302
303 The main functions of Cloud SCADA interface in device management are as follows:
304
305 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_3c59fa4c.png||height="21" width="19"]] Refresh the current Cloud SCADA project.
306
307 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_56dc36ee.png||height="20" width="19"]] Browse the current Cloud SCADA project in full screen (Press “Esc” exit).
308
309 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_23075dbb.png||height="19" width="19"]] Switch the bound Cloud SCADA projects (The cloud SCADA projects bound in current device and cross-device).
310
311 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1ced925.png||height="19" width="19"]] Edit the current cloud SCADA (jump to the Cloud SCADA edit page)
312
313
314 **(4) Basic information**
315
316 Include: "Basic information, status push, register information, version information" for the device.
317
318 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_b1d4b150.png||height="330" width="638"]]
319
320 ●**Device name:** Mainly used to distinguish various devices.
321
322 ●**Online status**: Use the refresh function to refresh the online status of the device.
323
324 ●**Machine code:** Each device has a unique and independent machine code.
325
326 ●**Map Information:** The latitude and longitude information of the device, click “Location” to view the geographical location and modify the location information.
327
328 ●**Located with:**
329
330 ① Use device base station positioning.        
331
332 ②Use manual positioning.
333
334 Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.
335
336
337 == {{id name="_Toc7609"/}}{{id name="_Toc19227"/}}**3 Pass-through of device** ==
338
339 {{id name="_Toc16958"/}}{{id name="_Toc18341"/}}{{id name="_Toc10036"/}}{{id name="_Toc14306"/}}{{id name="_Toc8318"/}}{{id name="_Toc23343"/}}{{id name="_Toc11131"/}}{{id name="_Toc21238"/}}{{id name="_Toc23066"/}}{{id name="_Toc22286"/}}{{id name="_Toc32206"/}}{{id name="_Toc14201"/}}{{id name="_Toc5622"/}}{{id name="_Toc10379"/}}{{id name="_Toc29542"/}}{{id name="_Toc3580"/}}{{id name="_Toc20482"/}}{{id name="_Toc22905"/}}{{id name="_Toc10700"/}}{{id name="_Toc2060"/}}{{id name="_Toc10051"/}}**Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
340
341 Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc.
342
343 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1c4453d8.png||height="338" width="638"]]
344
345 Device status description table is as follows:
346
347 |**Color**|**Color Value (HEX)**|**Status**|**Description**
348 |●|#18E600|Online|Pass-through available
349 |●|#B5C1D8|Offline|Pass-through is not allowed
350 |●|#1C9BFD|Pass-through connecting|In pass-through
351 |●|#005CFF|VPN connecting|In pass-through
352 |●|#FD8B09|VPN pass-through is reconnecting|Pass-through reconnecting due to network and other reasons
353 |●|#2C405E|VPN pass-through is ending|The end of pass-through due to [End pass-through]
354 |●|#109A00|Download is ready.|Download channel is ready. (Download can be executed.)
355 |●|#009577|Download|In download
356
357 **Pass-through precautions:**
358
359 ● The web cannot use the pass-through function for the time being, and it needs to be in the PC client to change the location.
360
361 ● When the device is offline, “Start pass-through” cannot be clicked.
362
363 ● When the device firmware version is too low, “Start pass-through” cannot be clicked.
364
365 ● The current user does not have pass-through rights on this device or this device is shared by others, and “Start pass-through” cannot be clicked.
366
367 ● When the current user has a device in pass-through, “Start pass-through” cannot be clicked.
368
369
370 === {{id name="_Toc28395"/}}**4.1 Device pass-through download (RE)** ===
371
372 The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet.
373
374 **Steps:**
375
376 ① Click [[image:Wecon V-BOX R Series User Manual 240611 V1.2_f1b46bca.png||height="16" width="17"]] to enter the pass-through interface.
377
378 ② Select the device that needs pass-through, and ensure that the device is online.
379
380 ③ Click "Browse" to automatically detect the installed download tools on this machine. The table shows the versions and locations of all installed download tools. (HMI software should be installed in the computer to ensure that HMIEditor and download tools exist at the same time).
381
382 ④ Select any HMI download tool configuration in the table, and confirm the selected HMIEditor software through the folder location and corresponding version information.
383
384 ⑤ Pass-through is ready → [Start pass-through].
385
386 ●Click "Start pass-through" to conduct pass-through according to the specified download tools and selected devices.
387
388 ● Click [End pass-through] to end pass-through.
389
390 ⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program.
391
392 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
393
394 === {{id name="_Toc21457"/}}{{id name="_Toc18124"/}}**4.2 Common serial port pass-through (PLC)** ===
395
396 Based on the normal communication between RE device and PLC or other device, PLC is connected according to the generated virtual serial port, allowing the PLC software on the computer to communicate and connect with the PLC, and completing the functions of uploading/downloading PLC programs and monitoring PLC programs.
397
398 **Steps:**
399
400 ① Virtual serial port settings: Click** [Settings]** →**[Virtual Serial Port]**→**[Enable Virtual Serial Port] **→**[Select Serial Port]**. Pay attention to the serial port, please do not reuse it. (When the COM port is changed, if a PLC or other software is connecting to the original COM port, it will be disconnected.)
401
402 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_54a850e2.png||height="136" width="639"]]
403
404 ② Remote download configuration: Click [PLC pass-through ][[image:Wecon V-BOX R Series User Manual 240611 V1.2_cfc415e2.png||height="14" width="15"]] →Select the device that requires pass-through→[New/Edit]→[New Template] Configure pass-through parameters: [Name], [Communication Port], [Connection Method], [Baud Rate], [Stop Bit], [Data Bit], [Check Bit], the configured parameters need to be consistent with the PLC serial port parameters →[OK]→Prompt "Add successfully!"→[OK].
405
406 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_353545eb.png||height="339" width="638"]]
407
408 ③ Pass-through steps: On the pass-through interface, click [Start pass-through]→after successful pass-through, it will prompt "pass-through succeeded"→[OK].
409
410 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_5b5ad7dd.png||height="339" width="638"]]
411
412 ④ After the pass-through is successful, the indicator light of the corresponding RE device on the PC will turn blue, and the [current status] will become pass-through, indicating that the device is in the "pass-through" status.
413
414 ✎**Note:** Do not click [End pass-through], otherwise you will exit the pass-through function.
415
416
417
418 {{id name="_Toc14659"/}}{{id name="_Toc5468"/}}{{id name="_Toc29362"/}}⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored.
419
420 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]]
421
422 {{id name="_Toc24528"/}}{{id name="_Toc6595"/}}{{id name="_Toc20246"/}}**Pass-through Precautions:**
423
424 ① In the process of PLC software remote access, the pass-through serial port of the RE device needs to maintain a normal communication state, and the network state needs to remain stable.
425
426 ② When the device is in the pass-through, COM indicator light will be in the off status. When the device ends the pass-through, it will automatically restart.
427
428 ③ The parameters of the PLC connection need to be consistent with the parameters generated by the virtual serial port.
429
430 ④ It is necessary to ensure that the PLC serial port of pass-through can support the upload/download function, otherwise the remote pass-through function cannot be realized.
431
432 === {{id name="_Toc21835"/}}**4.3 VPN pass-through (PLC)** ===
433
434 **VPN pass-through:** The pass-through function allows the application program on the computer to directly control the PLC device through the RE device, upload/download PLC programs, monitor PLC programs or other configuration information, etc.
435
436 **Steps:**
437
438 ① Click [VPN pass-through][[image:Wecon V-BOX R Series User Manual 240611 V1.2_74d5c70b.png||height="14" width="15"]] →Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK].
439
440 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]]
441
442 ② After pass-through is successful, the indicator light of the corresponding RE device on the PC will turn yellow, and [current status] will become in the VPN pass-through, indicating that the device is in the "pass-through" status. (**Note:** You cannot click [End pass-through], otherwise you will exit the pass-through.)
443
444 ③ After the pass-through is successful, a virtual network card will be generated. You can check whether the IP is generated through the network card of the computer, as shown below.
445
446 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a53a8121.png||height="336" width="638"]]
447
448 ④ When PLC software completes the remote operation, select [End pass-through]→Prompt "End VPN pass through successfully"→[OK], at this time the device will automatically restart, and after the restart is completed, the working status before pass-through will be restored.
449
450 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_40416c98.png||height="336" width="638"]]
451
452 **Pass-through precautions:**
453
454 ① The Ethernet port IP of RE device, the IP used by the VPN pass-through, and the IP of the PLC must be kept in the same network segment without conflict.
455
456 ② The IP connected to the PLC needs to be consistent with the IP of the PLC itself.
457
458 ③ When the device ends the pass-through function, RE device will automatically restart.
459
460 ④ If the VPN pass-through is unsuccessful, please refer to the "Frequently Asked Questions of Wecon VPN pass-through Tools" for troubleshooting.
461
462 The file path is as follows:
463
464 https:~/~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506 **Wecon Technology Co., Ltd 
507 Factory Address: 10th Building, Area E, Fuzhou Software Park, Gulou District, Fuzhou, Fujian Province, P.R.China
508 R&D Center: Floor 5-7, Block 6, Area F, Fuzhou Software Park, Gulou District, Fuzhou, Fujian, Province, P.R. China
509 Tel: +86-591-87868869 Fax: +86-591-87843899
510 Website: www.we-con.com.con/en