Wiki source code of R Series

Version 60.1 by Joe on 2024/11/29 15:16

Show last authors
1 == **1 Product description** ==
2
3 |**Series**|(% style="width:132px" %)**Model**|(% style="width:552px" %)**Description**
4 |(% rowspan="3" %)**R Series**|(% style="width:132px" %)RE-00|(% style="width:552px" %)1 network port, single serial port
5 |(% style="width:132px" %)RE-4G|(% style="width:552px" %)1 network port, single serial port, support 4G.
6 |(% style="width:132px" %)RH-WF|(% style="width:552px" %)(((
7 2 network ports, 1 HDMI interface, single serial port, 2 RS485 terminals, support WiFi
8
9 2 optocoupler isolated input (DI), 2 relay output (DO)
10 )))
11
12 === **1.1 Product appearance** ===
13
14 ==== **RE-00/RE-4G** ====
15
16 [[image:1723447082795-273.png]]
17
18 RE-00/RE-4G Appearance
19
20 [[image:1723447096815-592.png]]
21
22 RE-00/RE-4G Installation Dimensions
23
24 ==== **RH-WF** ====
25
26 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_2faa2eeb.gif||alt="Shape1" height="316" width="464"]]
27
28 (((
29 **WiFi antenna**
30 )))
31
32 RH-WF
33
34 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_99c3a18c.png||height="259" width="638"]]
35
36 Installation size
37
38
39 === **1.2 Product specifications** ===
40
41 (((
42 (% style="width:815px" %)
43 |=(% colspan="3" %)**Model/Specifications**|=**RE-00**|=**RE-4G**|=**RH-WF**
44 |(% colspan="3" %)**Item**|(% colspan="3" %)**Parameters**
45 |(% colspan="3" %)CPU|(% colspan="2" %)Cortex-A35 4-Core 1.2GHz|Cortex A55 4-Core 1.8GHz
46 |(% rowspan="3" %)Memory|(% colspan="2" %)Flash|(% colspan="2" %)128MB|8GB
47 |(% colspan="2" %)RAM|(% colspan="2" %)DDRII 64MB|2GB
48 |(% colspan="2" %)SD Card|(% colspan="2" %)N/A|TF card
49 |(% rowspan="8" %)(((
50 I/O
51
52 Interface
53 )))|(% colspan="2" %)USB HOST|(% colspan="2" %)1, no isolation|(((
54 USB 2.0*1 No isolation
55
56 USB 3.0*1 No isolation
57 )))
58 |(% colspan="2" %)USB DEVICE|(% colspan="2" %)1, no isolation|Type-C*1
59 |(% colspan="2" %)Serial port|(% colspan="2" %)COM1: RS232, RS422/RS485|(((
60 COM1: RS232, RS422/RS485 (2 in 1)
61
62 1 expansion serial port (terminal line)
63
64 [COM2: RS485]
65 )))
66 |(% colspan="2" %)Ethernet port|(% colspan="2" %)1|10/100M Interface*2
67 |(% colspan="2" %)WIFI module|(% colspan="2" %)N/A|Yes
68 |(% colspan="2" %)4G module|N/A|4G|N/A
69 |(% colspan="2" %)HDMI|(% colspan="2" %)N/A|HDMI 2.0*1
70 |(% colspan="2" %)I/O|(% colspan="2" %)N/A|2-channel relay output, 2-channel isolated input with optocoupler
71 |(% rowspan="2" %)Power supply|(% colspan="2" %)Input power supply|(% colspan="3" %)24V DC (12-28V DC)
72 |(% colspan="2" %)Power consumption|(% colspan="3" %)<10W
73 |(% rowspan="4" %)Specifications|(% colspan="2" %)Shell material|(% colspan="2" %)Cold rolled sheet|Engineering-plastics PC+AB5 (Flame retardant level)
74 |(% colspan="2" %)Dimensions (W*H*D)|(% colspan="2" %)101.0*73.2*26.8mm|125.0*93.7*51.0 mm
75 |(% colspan="2" %)Wall mounting hole dimensions|(% colspan="2" %)110.0*15.6 mm|/(Fastener mounting)
76 |(% colspan="2" %)Weight|(% colspan="2" %)0.26Kg|253g
77 |(% rowspan="4" %)(((
78 Operation
79
80 Environment
81 )))|(% colspan="2" %)Vibration resistance|(% colspan="3" %)Compile with IEC61131-2 standard
82 |(% colspan="2" %)Storage temperature|(% colspan="3" %)-20℃-70℃
83 |(% colspan="2" %)Working temperature|(% colspan="3" %)-10℃-60℃
84 |(% colspan="2" %)Ambient humidity|(% colspan="3" %)10-90% RH (No condensation)
85 |(% colspan="3" %)CE certification|(% colspan="3" %)Yes
86 |(% colspan="3" %)FCC certification|(% colspan="3" %)FCC Class A Certification
87 |(% colspan="2" %)Positioning function|(% colspan="2" %)N/A|Base station positioning|N/A
88 |(% rowspan="7" %)(((
89 Software
90
91 function
92 )))|(% colspan="2" rowspan="4" %)(((
93 Internet of Things Services
94
95 (Optional)
96 )))|(% colspan="2" %)100 real-time data tags|300 real-time data tags
97 |(% colspan="2" %)20 alarm data tags|200 alarm data tags
98 |(% colspan="2" %)50 historical data tags|100 historical data tags
99 |(% colspan="3" %)Days of historical data saved: 60 days/1 million
100 |(% colspan="2" %)Pass through|(% colspan="3" %)Yes
101 |(% colspan="2" %)VPN Pass trough|(% colspan="3" %)Yes
102 |(% colspan="2" %)API interface|(% colspan="3" %)Yes
103
104 === **1.3 Interface Description** ===
105 )))
106
107 ==== **Appearance component description** ====
108
109 **RE-00/RE-4G**
110
111 [[image:1723448311561-814.png]]
112
113 RE-00/RE-4G Component Description
114
115
116 |**1**|Indicator lamp|**2**|Micro-USB|**3**|Ethernet port|**4**|COM port
117 |**5**|Power supply|**6**|4G antenna (Optional)|**7**|Fixed fastener|**8**|SIM card (Optional)
118
119 **RH-WF**
120
121 [[image:1723448356737-113.png]]
122
123 RH-WF Component Description
124
125 |**1**|Indicator lamp|**2**|USB-A|**3**|Network Port 1|**4**|Network Port 2
126 |**5**|HDMI|**6**|TYPE-C|**7**|COM port|**8**|I/O interface and RS485 terminal
127 |**9**|Power supply|**10**|WIFI antenna|**11**|Fixed fastener| |
128
129 ==== **Interface Description** ====
130
131 **RE-00/RE-4G**
132
133 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d215ad34.png||height="276" width="616"]]
134
135
136 **RH-WF**
137
138 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_d48f58ee.png||height="240" width="488"]]
139
140 ==== **Interface Definition** ====
141
142 **RE-00/RE-4G COM1 interface definition**
143
144 |**Pin**|**Definition**|**Pin**|**Definition**
145 |1|RS422 TX+/RS485 A+|2|RS232 RXD
146 |3|RS232 TXD|5|GND
147 |6|RS422 TX-/RS485 B-|8|RS422 RX-
148 |9|RS422 RX+| |
149
150 **RH-WF**
151
152 |(% colspan="2" %)**Pin**|**Definition**
153 |(% rowspan="7" %)[[image:Wecon V-BOX R Series User Manual 240611 V1.2_ef6a7104.gif||height="205" width="93"]]|S/S|(((
154 Input mode selection terminal.
155
156 Connecting to 24V+ indicates that it supports** NPN** input;
157
158 Connecting to 24V- indicates that it supports **PNP** input.
159 )))
160 |Xn|Switch quantity input terminal
161 |Yn|Switch quantity signal output terminal, relay output
162 |COM|Output common port
163 |485+|RS485+
164 |485-|RS485-
165 |GND|Ground
166
167 == **2 Applications** ==
168
169 === Basic application ===
170
171 R series products, which can easily realize advanced requirements such as real-time display on industrial sites.
172
173 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_ab54a2bc.png||height="304" width="631"]]
174
175 ① Large-screen display, connect computer/TV Display the project screen;
176
177 ② Network port device, connect to network device such as slave computers, and download projects online through configuration software;
178
179 ③ Serial port device, connect to the serial port device of the slave computer, and the project can also be downloaded online through the configuration software.
180
181
182 === RH-WF and WS21 ===
183
184 RH-WF supports local HDMI interface to connect to in-site screen like a TV screen to display the project. WS21, a touching screen, can be connected with RH-WF via HDMI interface. The project an be operated manually in WS21 screen.
185
186 (% style="text-align:center" %)
187 [[image:图片1.png]]
188
189 (% style="text-align:center" %)
190 [[image:图片2.png]]
191
192 HDMI Port is for displaying the project. And USB Port is for touching.
193
194 [[WS21 parameter>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/Wecon%20WS21%20Monitor.pdf]]
195
196 [[Demo video>>https://ftp.we-con.com.cn/Download/WIKI/%E9%9B%9C%E9%A0%85/RH1.mp4]]
197
198 == **3 Operation Instructions** ==
199
200 === **3.1 Project Download-PIStudio** ===
201
202 **(1) New project**
203
204 PIStudio→[Home]→[New Project]→[Project Properties], and set the project name and [HMI model] in step by step: RE, RH series, select the detailed HMI model → [Screen style]: use the default do not set→[Done].
205
206 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8971673d.png||height="340" width="638"]]
207
208 **(2) Enable cloud server**
209
210 **Configuration of V-NET IoT System**
211
212 **It needs to check "Enable Cloud" function in order to view "Remote Monitoring" screen in V-NET, and configure the functions of tags, data recording on the cloud, and alarm recording on the cloud.**
213
214 Upload to the cloud: All configured tag information, historical information, and alarm information will be pushed to V-NET.
215
216
217 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_19762229.png||height="360" width="638"]]
218
219 **(3) Project compile/download**
220
221 After the project is completed, click **[Project Compile]**→After prompting that the compilation is completed, click** [Download Project]**→device detected, **[PC port]**. Ethernet or USB download→[PC→HMI]→pop up a prompt, click **[OK]** → complete the configuration project download, it will take effect after restart.
222
223 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_38834748.png||height="340" width="634"]]
224
225 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_31fafd4e.png||height="287" width="348"]]
226
227 **Note: “Flash light" in the picture is the flashing light of the detection device; "Test network" in the figure refers to the network status of the test device.**
228
229 === **3.2 Check V-NET IoT System** ===
230
231 ==== **3.2.1 V-NET login** ====
232
233 (1) New users must register first, and after the registration is successful, the user can use it.
234
235 ● A successfully registered account is an administrator account, which can bind the device and support other operations.
236
237 ● Users need to remember the registered account and password, and can log in simultaneously on the PC/APP.
238
239 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_7103ee91.png||height="274" width="453"]]
240
241 (2) Enter the account and password, and then click the **[Log in] **button.
242
243 (3) After admin account logs in to the platform, it will jump to the homepage by default, as shown in the figure below.
244
245 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_59ff7f12.png||height="357" width="598"]]
246
247 ==== **3.2.2 Adding devices** ====
248
249 (1) After successfully logging in, enter the** [Device Management]** interface, and add the device information to be accessed through the “+” button in the bar.
250
251 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_45c9855a.png||height="409" width="638"]]
252
253 (2) After the **[Add Device]** window pops up, enter the device machine code and password, etc., and add the device. Other instructions are as follows:   
254
255 ① **Device machine code:** Each device has a unique and independent machine code for remote monitoring device identification.     
256
257 Obtain machine code:
258
259 ● HMI PIStudio-**[Tool]**-**[Download project]**-Machine code.
260
261 ● Scan the QR code of the device to obtain the machine code.
262
263 ② **Device password:** Refers to the cloud access password, the default is 888888. The initial binding device password: see [[Cloud Configuration>>path:mk:@MSITStore:E:%5C%5CA%E6%97%A5%E5%B8%B8%E5%B7%A5%E4%BD%9C%E6%96%87%E4%BB%B6%5C%5C2023-06-15PI%E5%B8%AE%E5%8A%A9%E6%89%8B%E5%86%8C%5C%5C%E4%B8%AD%E6%80%A7%E7%89%8820231016%EF%BC%88%E6%A0%87%E5%87%86%EF%BC%89%5C%5Chelp20231020.chm::/levi%E2%85%A1/5/5.9.htm]].
264
265 ③ **Device alias:** Refers to the name recognition of the device in the menu bar of V-NET.
266
267 (3) Binding device is successful, click OK, prompt: Bind device successful!
268
269 ==== **3.2.3 V-NET check** ====
270
271 **(1) Remote monitoring**
272
273 The remote monitoring module can display the current screen in real time, and realize the operation of the project on the web page, realize the remote monitoring of the device and the control of the screen.
274
275 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a262a004.png||height="362" width="638"]]
276
277 **(2) Data viewing**
278
279 Data view has six modules, including Communication port, Collection point, Alarm configuration, Alarm record, Historical configuration, Historical data record.
280
281 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_6ce8af63.png||height="357" width="638"]]
282
283 **The specific parameter is as follows:**
284
285 ① **Communication port:** The communication port information, connection mode and protocol name configured on HMI. It can only be viewed, and cannot be added or modified. The information comes from what is set on HMI.
286
287 ② **Collection point**: Data monitoring module. The collection point is the tag, and its read-write, write-only, and read-only permissions also come from the tags set in PIStudio. (**Note: Tags cannot be added or removed here.**)
288
289 ③ **Alarm message:** For the alarm record of the device, tags cannot be added. Operations such as confirming the alarm record and exporting data can be performed.
290
291 ④ **Historical information:** The historical data of the device cannot add tag, supports curve and list viewing, and supports export historical data and other operations.
292
293 **(3) Cloud configuration**
294
295 The cloud SCADA platform is mainly used to display the monitoring/operation interface of the bound device in the V-NET.
296
297 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_8ecdd915.png||height="332" width="638"]]
298
299 The main functions of Cloud SCADA interface in device management are as follows:
300
301 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_3c59fa4c.png||height="21" width="19"]] Refresh the current Cloud SCADA project.
302
303 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_56dc36ee.png||height="20" width="19"]] Browse the current Cloud SCADA project in full screen (Press “Esc” exit).
304
305 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_23075dbb.png||height="19" width="19"]] Switch the bound Cloud SCADA projects (The cloud SCADA projects bound in current device and cross-device).
306
307 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1ced925.png||height="19" width="19"]] Edit the current cloud SCADA (jump to the Cloud SCADA edit page)
308
309
310 **(4) Basic information**
311
312 Include: "Basic information, status push, register information, version information" for the device.
313
314 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_b1d4b150.png||height="330" width="638"]]
315
316 ●**Device name:** Mainly used to distinguish various devices.
317
318 ●**Online status**: Use the refresh function to refresh the online status of the device.
319
320 ●**Machine code:** Each device has a unique and independent machine code.
321
322 ●**Map Information:** The latitude and longitude information of the device, click “Location” to view the geographical location and modify the location information.
323
324 ●**Located with:**
325
326 ① Use device base station positioning.        
327
328 ②Use manual positioning.
329
330 **Note: After modifying the basic information of the device, you need to click Save below to save successfully. If the save is not successful, please click Force Sync.**
331
332
333 == **4 Pass-through of device** ==
334
335 **Note: The pass-through operation steps of V-NET/V-IEC are for reference only.**
336
337 Pass-through function: The pass-through function allows applications on the computer to increase maintenance value through RE devices, remote pass-through devices, download projects, etc.
338
339 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_1c4453d8.png||height="338" width="638"]]
340
341 Device status description table is as follows:
342
343 |(% style="width:82px" %)**Color**|(% style="width:248px" %)**Color Value (HEX)**|**Status**|**Description**
344 |(% style="width:82px" %)[[image:1723449592784-532.png]]|(% style="width:248px" %)#18E600|Online|Pass-through available
345 |(% style="width:82px" %)[[image:1723449624928-809.png]]|(% style="width:248px" %)#B5C1D8|Offline|Pass-through is not allowed
346 |(% style="width:82px" %)[[image:1723449706265-533.png]]|(% style="width:248px" %)#1C9BFD|Pass-through connecting|In pass-through
347 |(% style="width:82px" %)[[image:1723449737329-134.png||height="28" width="31"]]|(% style="width:248px" %)#005CFF|VPN connecting|In pass-through
348 |(% style="width:82px" %)[[image:1723449765210-888.png]]|(% style="width:248px" %)#FD8B09|VPN pass-through is reconnecting|Pass-through reconnecting due to network and other reasons
349 |(% style="width:82px" %)[[image:1723449785743-305.png||height="28" width="32"]]|(% style="width:248px" %)#2C405E|VPN pass-through is ending|The end of pass-through due to [End pass-through]
350 |(% style="width:82px" %)[[image:1723449827434-119.png]]|(% style="width:248px" %)#109A00|Download is ready.|Download channel is ready. (Download can be executed.)
351 |(% style="width:82px" %)[[image:1723449809049-353.png]]|(% style="width:248px" %)#009577|Download|In download
352
353 **Pass-through precautions:**
354
355 ● The web cannot use the pass-through function for the time being, and it needs to be in the PC client to change the location.
356
357 ● When the device is offline, “Start pass-through” cannot be clicked.
358
359 ● When the device firmware version is too low, “Start pass-through” cannot be clicked.
360
361 ● The current user does not have pass-through rights on this device or this device is shared by others, and “Start pass-through” cannot be clicked.
362
363 ● When the current user has a device in pass-through, “Start pass-through” cannot be clicked.
364
365
366 === **4.1 Device pass-through download (RE)** ===
367
368 The pass-through function allows applications on the computer to download projects to RE device remotely pass-through through Ethernet.
369
370 **Steps:**
371
372 ① Click [[image:Wecon V-BOX R Series User Manual 240611 V1.2_f1b46bca.png||height="16" width="17"]] to enter the pass-through interface.
373
374 ② Select the device that needs pass-through, and ensure that the device is online.
375
376 ③ Click "Browse" to automatically detect the installed download tools on this machine. The table shows the versions and locations of all installed download tools. (HMI software should be installed in the computer to ensure that HMIEditor and download tools exist at the same time).
377
378 ④ Select any HMI download tool configuration in the table, and confirm the selected HMIEditor software through the folder location and corresponding version information.
379
380 ⑤ Pass-through is ready → [Start pass-through].
381
382 ●Click "Start pass-through" to conduct pass-through according to the specified download tools and selected devices.
383
384 ●Click [End pass-through] to end pass-through.
385
386 ⑥ After pass-through is successful, pop up the download tool box, select [PC->HMI], select the compiled .wmt3 file, and download the program.
387
388 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_221b5f45.png||height="338" width="638"]]
389
390 === **4.2 Common serial port pass-through (PLC)** ===
391
392 Based on the normal communication between RE device and PLC or other device, PLC is connected according to the generated virtual serial port, allowing the PLC software on the computer to communicate and connect with the PLC, and completing the functions of uploading/downloading PLC programs and monitoring PLC programs.
393
394 **Steps:**
395
396 ① Virtual serial port settings: Click** [Settings]** →**[Virtual Serial Port]**→**[Enable Virtual Serial Port] **→**[Select Serial Port]**. Pay attention to the serial port, please do not reuse it. (When the COM port is changed, if a PLC or other software is connecting to the original COM port, it will be disconnected.)
397
398 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_54a850e2.png||height="136" width="639"]]
399
400 ② Remote download configuration: Click [PLC pass-through ][[image:Wecon V-BOX R Series User Manual 240611 V1.2_cfc415e2.png||height="14" width="15"]] →Select the device that requires pass-through→[New/Edit]→[New Template] Configure pass-through parameters: [Name], [Communication Port], [Connection Method], [Baud Rate], [Stop Bit], [Data Bit], [Check Bit], the configured parameters need to be consistent with the PLC serial port parameters →[OK]→Prompt "Add successfully!"→[OK].
401
402 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_353545eb.png||height="339" width="638"]]
403
404 ③ Pass-through steps: On the pass-through interface, click [Start pass-through]→after successful pass-through, it will prompt "pass-through succeeded"→[OK].
405
406 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_5b5ad7dd.png||height="339" width="638"]]
407
408 ④ After the pass-through is successful, the indicator light of the corresponding RE device on the PC will turn blue, and the [current status] will become pass-through, indicating that the device is in the "pass-through" status.
409
410 ✎**Note:** Do not click [End pass-through], otherwise you will exit the pass-through function.
411
412
413
414 ⑤End pass-through: When the PLC software completes the remote operation, select [End pass-through]→Prompt "End pass-through successfully"→[OK], at this time the device will automatically restart. After the restart is completed, the working status before pass-through will be restored.
415
416 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_c6ec3cf0.png||height="337" width="638"]]
417
418 **Pass-through Precautions:**
419
420 ① In the process of PLC software remote access, the pass-through serial port of the RE device needs to maintain a normal communication state, and the network state needs to remain stable.
421
422 ② When the device is in the pass-through, COM indicator light will be in the off status. When the device ends the pass-through, it will automatically restart.
423
424 ③ The parameters of the PLC connection need to be consistent with the parameters generated by the virtual serial port.
425
426 ④ It is necessary to ensure that the PLC serial port of pass-through can support the upload/download function, otherwise the remote pass-through function cannot be realized.
427
428 === **4.3 VPN pass-through (PLC)** ===
429
430 **VPN pass-through:** The pass-through function allows the application program on the computer to directly control the PLC device through the RE device, upload/download PLC programs, monitor PLC programs or other configuration information, etc.
431
432 **Steps:**
433
434 ① Click [VPN pass-through] [[image:1723450415577-521.png]]→Select the device that requires pass-through →[Local pass-through IP]→[Automatic acquisition/manual setting]→[Manual setting] 192.168.40.23 (Manual IP setting needs to ensure that it is on the same network segment as the RE device and device IP)→[Start pass-through]→Prompt "Pass-through succeeded"→[OK].
435
436 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a4500d0f.png||height="335" width="638"]]
437
438 ② After pass-through is successful, the indicator light of the corresponding RE device on the PC will turn yellow, and [current status] will become in the VPN pass-through, indicating that the device is in the "pass-through" status. (**Note:** You cannot click [End pass-through], otherwise you will exit the pass-through.)
439
440 ③ After the pass-through is successful, a virtual network card will be generated. You can check whether the IP is generated through the network card of the computer, as shown below.
441
442 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_a53a8121.png||height="336" width="638"]]
443
444 ④ When PLC software completes the remote operation, select [End pass-through]→Prompt "End VPN pass through successfully"→[OK], at this time the device will automatically restart, and after the restart is completed, the working status before pass-through will be restored.
445
446 [[image:Wecon V-BOX R Series User Manual 240611 V1.2_40416c98.png||height="336" width="638"]]
447
448 **Pass-through precautions:**
449
450 ① The Ethernet port IP of RE device, the IP used by the VPN pass-through, and the IP of the PLC must be kept in the same network segment without conflict.
451
452 ② The IP connected to the PLC needs to be consistent with the IP of the PLC itself.
453
454 ③ When the device ends the pass-through function, RE device will automatically restart.
455
456 ④ If the VPN pass-through is unsuccessful, please refer to the "Frequently Asked Questions of Wecon VPN pass-through Tools" for troubleshooting.
457
458 The file path is as follows:
459
460 [[https:~~/~~/www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf>>https://www.we-con.com.cn/uploads/image/20210811/611392100b634.pdf]]
461
462 == 5 Resumable upload ==
463
464 3000ig/8000ig HMI and RE/RH,E/H V-BOX can support  a function for resumable upload. The function is to save lost data when the device is offline and upload lost data to Cloud when the device is online again.
465
466 The following table shows the maximum number of the resumable data and the biggest file size of the resumable data:
467
468 |= |=RE/RH|=3000ig/8000ig HMI|=E/H V-BOX
469 |=data|100,000|100,000|2,000
470 |=file size|2M|2M|N/A
471
472 (% class="box infomessage" %)
473 (((
474 Note:
475
476 1.The function don't configure by manual.
477
478 2.When the device is online again, There is a keep-alive interval for about 30s. So data will be lost during the time.
479 )))
480
481 == 6 Remote Background ==
482
483 R series box doesn’t have the actual screen, so a new remote page is designed for background setting if user want to change some background parameters.
484
485 (% class="box infomessage" %)
486 (((
487 Note: HMI of V3.0 version also supports this function.
488 )))
489
490 === Enter remote background ===
491
492
493 Keep R series/HMI and pc in the same Lan. Input "IP:9091" in pc webpage.
494
495 (% style="text-align:center" %)
496 [[image:TYyajNRreA.png]]
497
498 There will be a User login screen and input Account and Password.
499
500 (% style="text-align:center" %)
501 [[image:zt10uj9hHA.png]]
502
503 (% class="box infomessage" %)
504 (((
505 Note: The default Account is "admin". The default Password is "888888".
506 )))
507
508 === Modify account and password ===
509
510 Project Settings → Security→ LAN Monitoring Security→ OK → Compile and Download the project
511
512 (% style="text-align:center" %)
513 [[image:rDTHQo0uzs.png]]
514
515 == 7 Centralized Monitor ==
516
517 In HMI V3.0 version, there will be a Device management tool for centralized monitoring Local and Cloud device. When HMIs and PC are in the same LAN, they can be selected for centralized monitor.
518
519 (% class="box infomessage" %)
520 (((
521 Note: Centralized Monitor can not be accomplished by connection that HMIs are connected to PC with USB.
522 )))
523
524 === Local Device ===
525
526 Download → choose monitored HMIs
527
528 (% style="text-align:center" %)
529 [[image:1yeIHMWarO.png]]
530
531 === Cloud Device ===
532
533 Cloud Linker →log in → select the server in configuration→ log in V-net Client account
534
535 (% style="text-align:center" %)
536 [[image:DTQ10E5Cv6.png]]
537
538 (% style="text-align:center" %)
539 [[image:IPJDUDCzD4.png]]
540
541 After logging in the account, select monitored HMIs.
542
543 (% style="text-align:center" %)
544 [[image:y6AlyJtG24.png]]
545
546 In Centralized monitor screen, selected HMI project will be display here. What's more, these projects can be operated in the screen.
547
548 (% style="text-align:center" %)