5-9 System-special address

Version 5.1 by Jim on 2023/01/14 09:59

system-special address list

MDescriptionLX1SLX2N or laterDDescriptionLX1SLX2N or later 

System operation

 
M8000RUN monitor, NO contactOOD8000Watchdog timerOO 
M8001RUN monitor, NC contactOOD8001

PLC type and version

LX3V/3V-A2:250**

LX3V-A1: 220**

LX3VP: 251**

LX2V: 240**

** is viewed by D8101

OO 
M8002Initial pulse NO contactOOD8002

Memory capacity

0002: 2K steps

0004: 4K steps

0008: 8K step

OO 
M8003Initial pulse NC contactOOD8003Memory type default value is 0x10.OO 
M8004ON when one or more error flags from the range M8060to M8067 [except M8062]are ONOOD8004Error BCD code of M8060~M8067, the default value is 0.OO 
M8005Battery voltage Low-OD8005Battery voltage-O 
M8006Battery error latch-OD8006The level at which a battery voltage low is detected-O 
M8007Power loss has occurred more than 5ms, M8007&M8008 are ON-OD8007The number of time a momentary power failure has occurred since power ON.-O 
M8008Power loss has occurred-OD8008The time period before shutdown when a power failure occurs (default 10ms)-O 
M8009Power failure of 24V DC service supply-OD8009The device number of module, which affected by 24VDC power failure-O 

Clock Devices

 
M8010ReservedOOD8010Current operation cycle / scould time in units of 0.1 msecOO 
M8011Oscillates in 10 msec cyclesOOD8011Minimum cycle/ scould time in units of 0.1 msecOO 
M8012

Oscillates in 100 msec

cycles

OOD8012Maximum cycle/ scould time inunits of 0.1 msecOO 
M8013Oscillates in 1 sec cyclesOOD8013Seconds data for use with an RTC (0-59)OO 
M8014Oscillates in 1 min cyclesOOD8014Minute data for use with anRTC (0-59)OO 
M8015When ON - clock stops, ON→OFF restarts clockOOD8015Hour data for use with an RTC (0-23)OO 
M8016

When ON D8013 to 19 are frozen for display but clock

continues

OOD8016Day data for use with an RTC (1-31)OO 
M8017When pulsed ON set RTC to nearest minuteOOD8017Month data for use with an RTC (1-12)OO 
M8018When ON Real Time Clockis installedOOD8018Year data for use with an RTC (2000-2099)OO 
M8019Clock data has been set outof rangeOOD8019Weekday data for use with an RTC (0-6)OO 

Operation Flags

 
M8020Set when the result of anADDor SUBis “0”OOD8020Input filter setting for devicesX000 to X007 default is 10msec, (0-60)OO 
M8021

Set when the result of a SUBis less than the

min. negative number

OOD8021Reserved   
M8022Set when ‘carry’ occurs during an ADD orwhen an overflow occurs asa result of a data shift operationOOD8022Reserved   
M8023ReservedOOD8023Reserved   
M8024Direction of BMOV-OD8024Reserved   
M8025HSC mode-OD8025Reserved   
M8026RAMP mode-OD8026Reserved   
M8027PR 16 element data string-OD8027Reserved   
M8028Switch100ms/10ms timerO-D8028Current value of the Z index registerOO 
M8029Instruction execution complete such as PLSROOD8029Current value of the V index registerOO 

PLC Operation Mode

 
M8030Battery voltage is low but BATT.V LED not lit-OD8030Reserved   
M8031Clear all unsaved memoryOOD8031Reserved   
M8032Clear all the saved memoryOOD8032Reserved   
M8033The device statuses and settings are retained when thePLC changes from RUN toSTOP and back into RUNOOD8033Reserved   
M8034All of the physical switchgear for activating outputs is disabled. However, the program still operates normally.OOD8034Reserved   
M8035Forced operation 1OOD8035Reserved   
M8036Forced operation 2OOD8036Reserved   
M8037Forced stopOOD8037Reserved   
M8038Communication parameter setting flagOOD8038Reserved   
M8039Constant scan controlOOD8039Constant scan time, default 0, in units of MSOO 

Step Ladder (STL) Flags

 
M8040When ON STL state transfer is disabledOOD8040Up to 8 active STL states, from the range S0 to S899, are stored in D8040 to D8047 in ascending numerical order (Updated at END)OO 
M8041When ON STL transfer from initial state is enabled during automatic operationOOD8041OO 
M8042A pulse output is given in response to a start inputOOD8042OO 
M8043On during the last state of ZERO RETURN modeOOD8043OO 
M8044ON when the machine zero is detectedOOD8044OO 
M8045Disables the all output reset function when the operation mode is changedOOD8045OO 
M8046ON when STL monitoring has been enable (M8047)OOD8046OO 
M8047When ON D8040 to D8047 are enabled for active STL step monitoringOOD8047OO 
M8048ON when annunciator monitoring has been enabled (M8049) and there is an active annunciator flag-OD8048Reserved   
M8049When ON D8049 is enabled for actove annunciator state monitoring.-OD8049Stores the lowest currently active annunciator from the range S900 to S999 (Updated at END)-O 

Interrupt Control Flags

 
M8050I00□ disabledOOD8050Reserved   
M8051I10□ disabledOOD8051Reserved   
M8052I20□ disabledOOD8052Reserved   
M8053I30□ disabledOOD8053Reserved   
M8054I40□ disabledOOD8054Reserved   
M8055I50□ disabledOOD8055Reserved   
M8056I6□□ disabled-OD8056Reserved   
M8057I7□□ disabled-OD8057Reserved   
M8058I8□□ disabled-OD8058Reserved   
M8059Counters disabled-OD8059Reserved   

Error Detection

 
M8060I/O configuration error-OD8060The first I/O number of the unit or block causing the error-O 
M8061PLC hardware errorOOD8061Error code for hardware errorOO 
M8062PLC communication error-OD8062Error code for PLC Communications error-O 
M8063Parallel link errorOOD8063Error code for parallel link errorOO 
M8064Parameter errorOOD8064Error code identifying parameter errorOO 
M8065Syntax errorOOD8065Error code identifying syntax errorOO 
M8066Loop errorOOD8066Error code identifying loop errorOO 
M8067Operation errorOOD8067Error code identifying operation error.OO 
M8068Operation error latchOOD8068Operation error step number latchedOO 
M8069Reserved  D8069Step numbers for found errors corresponding to flags M8065 to M8067OO 

High-speed ring counter

 
M8099High-speed ring counter operationOOD8099High-speed ring counter, range: 0 to 32,767 in units of 0.1 msOO 

Other functions

 
M8100SPD (X000) pulse/ minuteOOD8100ReservedOO 
M8101SPD (X001) pulse/ minuteOOD8101

Firmware sub-version

LX3V/3VP: 160**

LX2V: 240**

The ** and D8001** combines a complete firmware version number

OO 
M8102SPD (X002) pulse/ minuteOOD8102User program capacityOO 
M8103SPD (X003) pulse/ minuteOOD8103ReservedOO 
M8104SPD (X004) pulse/ minuteOOD8104The AC/DE time for DRVI, DRVA, [100 ms default value] it effected by M8135 (Y0), it must be the same as D8165.OO 
M8105SPD (X005) pulse/ minuteOOD8105The AC/DE time for DRVI, DRVA, [100 ms default value] it effected by M8135 (Y1), it must be the same as D8166.OO 
M8106Reserved  D8106The AC/DE time for DRVI, DRVA, [100 ms default value] it effected by M8135 (Y2), it must be the same as D8167.OO 
M8107Reserved  D8107The AC/DE time for DRVI, DRVA, [100 ms default value] it effected by M8135 (Y3), it must be the same as D8168.OO 
M8108Reserved  D8108Reserved   
M8109Output refresh errorOOD8109Output refresh error device number;OO 

COM1 communication settings&BD module configuration

 
M8110Reserved  D8110Com1 port setting (only available in 22319, 24320, 25007 or later)OO 
M8111Reserved  D8111Reserved   
M8112BD module 1 channel 1 flag bit  D8112BD module 1 channel 1 data   
M8113BD module 1 channel 2 flag bit  D8113BD module 1 channel 2 data   
M8114BD module 1 channel 3 flag bit  D8114BD module 1 channel 3 data   
M8115BD module 1 channel 4 flag bit  D8115BD module 1 channel 4 data   
M8116BD module 2 channel 1 flag bit  D8116BD module 2 channel 1 data   
M8117BD module 2 channel 2 flag bit  D8117BD module 2 channel 2 data   
M8118BD module 2 channel 3 flag bit  D8118BD module 2 channel 3 data   
M8119BD module 2 channel 4 flag bit  D8119BD module 2 channel 4 data   

COM2 communication settings

 
M8120Reserved  D8120Com2 port setting, the default value is 0OO 
M8121Sending and waiting (RS instruction)OOD8121Station number settings, the default value is 1OO 
M8122

Sending flag (RS instruction)

Instruction execution status (MODBUS)

OOD8122Amount of remaining data to be transmitted (Only for RS instruction) unit:0.1msOO 
M8123

Receiving complete flag (RS)

Communication error flag (MODBUS)

OOD8123Amount of data already received (Only to RS instruction)OO 
M8124Receiving (only to RS instruction)OOD8124Start character STX (Only to RS instruction)OO 
M8125Reserved  D8125End character ETX (Only to RS instruction)OO 
M8126Reserved  D8126Communication protocol setting, the default value is 0OO 
M8127Reserved  D8127Starting address for PC protocolOO 
M8128Reserved  D8128Data length for PC protocolOO 
M8129Timeout judgementOOD8129Timeout judgement, default value is 10 (100ms)OO 

High speed & Position

 
M8130Selects comparison tables to be used with the HSZ instructionOOD8130Contains the number of the current record being processed in the HSZ comparison tableOO 
M8131OOD8131HSZ&PLSY speed modeOO 
M8132HSZ&PLSY speed modeOOD8132HSZ&PLAY speed mode frequencyLowOO 
M8133OOD8133- 
M8134Reserved  D8134HSZ&PLAY speed mode pulsesLowOO 
M8135Reserved  D8135High 
M8136Reserved  D8136total output pulse of Y000&Y001LowOO 
M8137Reserved  D8137High 
M8138Reserved  D8138Reserved   
M8139Reserved  D8139Reserved   
M8140The CLR signal output function of ZRN is validOOD8140Accumulated value of PLSY & PLSR output pulse in Y000LowOO 
M8141Accumulator register of output pulse could latched when turn ON (D8136, D8137, D8140~D8143, D8150~D8153)OOD8141High 
M8142Reserved  D8142Accumulated value of PLSY & PLSR output pulse in Y001LowOO 
M8143Reserved  D8143High 
M8144Reserved  D8144Reserved   
M8145Stop pulse output in Y000OOD8145Bias speed of DRVI & DRVAOO 
M8146Stop pulse output in Y001OOD8146Highest speed of DRVI & DRVA (default is 100,000)LowOO 
M8147Monitor pulse output in Y000OOD8147High 
M8148Monitor pulse output in Y001OOD8148ACC/DEC time of DRVI & DRVA (default is 100)OO 
M8149Monitor pulse output in Y002OOD8149Reserved   
M8150Monitor pulse output in Y003OOD8150Accumulated value of PLSY & PLSR output pulse in Y002LowOO
M8151Reserved  D8151High
M8152Stop pulse output in Y002OOD8152Accumulated value of PLSY & PLSR output pulse in Y003LowOO
M8153Stop pulse output in Y003OOD8153High
M8154Reserved  D8154Reserved   
M8155Reserved  D8155Reserved   

Extend function

 
M8156Reserved  D8156ReservedOO 
M8157Reserved  D8157ReservedOO 
M8158Reserved  D8158ReservedOO 
M8159Reserved  D8159ReservedOO 
M8160SWAP function is XCH-OD8160ReservedOO 
M8161Bit processing mode of ASC/RS/ASCII/HEX/CCDOOD8161Reserved   
M8162High-speed connection in parallel modeOOD8162Reserved   
M8163Reserved  D8163Reserved   
M8164Variable transmission points mode (FROM/TO)-OD8164Special transmission points mode (FROM/TO)OO 
M8165Reserved  D8165When enable acceleration and deceleration time, ensure the values is the same as D8104'sOO 
M8166Reserved  D8166When enable acceleration and deceleration time, ensure the values is the same as D8105'sOO 
M8167HEX processing function of SMOV-OD8167When enable acceleration and deceleration time, ensure the values is the same as D8106'sOO 
M8168HEX processing function of HEY-OD8168When enable acceleration and deceleration time, ensure the values is the same as D8107'sOO 
M8169Reserved  D8169Reserved   
Pulse catchCommunication 
M8170X000 pulse catchOOD8170Reserved   
M8171X001 pulse catchOOD8171Reserved   
M8172X002 pulse catchOOD8172Reserved   
M8173X003 pulse catchOOD8173Station number setting stateOO 
M8174X004 pulse catchOOD8174Communication sub-station setting stateOO 
M8175X005 pulse catchOOD8175Refresh range setting stateOO 
M8176Reserved  D8176Station number settingOO 
M8177Reserved  D8177Communication sub-station settingOO 
M8178Reserved  D8178Refresh range settingOO 
M8179Reserved  D8179Retries settingOO 
M8180Reserved  D8180Timeout settingOO 
CommunicationIndexed addressing 
M8181Reserved  D8181Reserved   
M8182Reserved  D8182No.2 bit device/ Content of Z1 deviceOO 
M8183Master transfers data errorOOD8183No.3 bit device/ Content of V1 deviceOO 
M8184Slave 1 transfers data errorOOD8184No.4 bit device/ Content of Z2 deviceOO 
M8185Slave 2 transfers data errorOOD8185No.5 bit device/ Content of V2 deviceOO 
M8186Slave 3 transfers data errorOOD8186No.6 bit device/ Content of Z3 deviceOO 
M8187Slave 4 transfers data errorOOD8187No.7 bit device/ Content of V3 deviceOO 
M8188Slave 5 transfers data errorOOD8188No.8 bit device/ Content of Z4 deviceOO 
M8189Slave 6 transfers data errorOOD8189No.9 bit device/ Content of V4 deviceOO 
M8190Slave 7 transfers data errorOOD8190No.10 bit device/ Content of Z5 deviceOO 
M8191Data transferringOOD8191No.11 bit device/ Content of V5 deviceOO 
M8192Reserved  D8192No.12 bit device/ Content of Z6 deviceOO 
M8193Reserved  D8193No.13 bit device/ Content of V6 deviceOO 
M8194Reserved  D8194No.14 bit device/ Content of Z7 deviceOO 
M8195Reserved  D8195No.15 bit device/ Content of V7 deviceOO 
M8196Reserved  D8196Reserved   
M8197Reserved  D8197Reserved   
M8198Reserved  D8198Reserved   
M8199Reserved  D8199Reserved   
Counters statesCommunication 
M8200C200 ControlOOD8200

Frequency multiplication of C251 device

D8200=0: 1 frequency multiplication

D8200=1: 2 frequency multiplication

D8200=2: 4 frequency multiplication

Note: HSCS, HSCR and HSCZ instructions could be used with frequency multiplication simultaneously. And this function is available in V311 or later version

OO 
M8201C201 ControlOOD8201Reserved   
M8202C202 ControlOOD8202Reserved   
M8203C203 ControlOOD8203Reserved   
M8204C204 ControlOOD8204Reserved   
M8205C205 ControlOOD8205Reserved   
M8206C206 ControlOOD8206Reserved   
M8207C207 ControlOOD8207Reserved   
M8208C208 ControlOOD8208Reserved   
M8209C209 ControlOOD8209Reserved   
M8210C210 ControlOOD8210Reserved   
M8211C211 ControlOOD8211Reserved   
M8212C212 ControlOOD8212Reserved   
M8213C213 ControlOOD8213Reserved   
M8214C214 ControlOOD8214Reserved   
M8215C215 ControlOOD8215Reserved   
M8216C216 ControlOOD8216Reserved   
M8217C217 ControlOOD8217Reserved   
M8218C218 ControlOOD8218Reserved   
M8219C219 ControlOOD8219Reserved   
M8220C220 ControlOOD8220

D8220=1 to enable the new filtering methods (four points constitute a set of filter). When use new filtering methods, the filter time which set by D8020 is not valid. And before using this filtering methods, users need to set the filtering time for each X terminals (D8221~D8228), Filter time unit is ms.

Note: This filter method only works on CPU IO, the IO in extension module is not invalid.

OO 
M8221C221 ControlOOD8221

Low bits are for setting filter time of X0~X3;

High bits are for setting filter time of X4~X7

Unit is ms

OO 
M8222C222 ControlOOD8222

Low bits are for setting filter time of X10~X13;

High bits are for setting filter time of X14~X17

Unit is ms

OO 
M8223C223 ControlOOD8223

Low bits are for setting filter time of X20~X23;

High bits are for setting filter time of X24~X27

Unit is ms

OO 
M8224C224 ControlOOD8224

Low bits are for setting filter time of X30~X33;

High bits are for setting filter time of X34~X37

Unit is ms

OO 
M8225C225 ControlOOD8225

Low bits are for setting filter time of X40~X43;

High bits are for setting filter time of X44~X47

Unit is ms

OO 
M8226C226 ControlOOD8226

Low bits are for setting filter time of X50~X53;

High bits are for setting filter time of X54~X57

Unit is ms

OO 
M8227C227 ControlOOD8227

Low bits are for setting filter time of X60~X63;

High bits are for setting filter time of X64~X67

Unit is ms

OO 
M8228C228 ControlOOD8228

Low bits are for setting filter time of X70~X73;

High bits are for setting filter time of X74~X77

Unit is ms

OO 
M8229C229 ControlOOD8229Reserved   
M8230C230 ControlOOD8230Reserved   
M8231C231 ControlOOD8231Reserved   
M8232C232 ControlOOD8232Reserved   
M8233C233 ControlOOD8233Reserved   
M8234C234 ControlOOD8234Reserved   
M8235One phase one directionalC235 ControlOOD8235Reserved   
M8236C236 ControlOOD8236Reserved   
M8237C237 ControlOOD8237Reserved   
M8238C238 ControlOOD8238Reserved   
M8239C239 ControlOOD8239Reserved   
M8240C240 ControlOOD8240Reserved   
M8241C241 ControlOOD8241Reserved   
M8242C242 ControlOOD8242Reserved   
M8243C243 ControlOOD8243Reserved   
M8244C244 ControlOOD8244Reserved   
M8245C245 ControlOOD8245Reserved   
M82462 phase bi-directionalC246 ControlOOD8246Reserved   
M8247C247 ControlOOD8247Reserved   
M8248C248 ControlOOD8248Reserved   
M8249C249 ControlOOD8249Reserved   
M8250C250 ControlOOD8250Reserved   
M8251A/B phaseC251 ControlOOD8251Reserved   
M8252C252 ControlOOD8252Reserved   
M8253C253 ControlOOD8253Reserved   
M8254C254 ControlOOD8254Reserved   
M8255C255 ControlOOD8255Reserved