Changes for page 01 Precaution

Last modified by Joe on 2025/03/11 17:58

From version 12.1
edited by Leo Wei
on 2022/07/21 17:55
Change comment: There is no comment for this version
To version 10.1
edited by Stone Wu
on 2022/07/21 17:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.admin
1 +XWiki.Stone
Content
... ... @@ -1,9 +1,12 @@
1 -= 1 Safety =
1 +(% class="wikigeneratedid" id="H2.1PDFDownloadLink:" %)
2 +PDF Download Link:
2 2  
3 3  (((
4 -
5 +**[[Download>>doc:PLC Editor.1 User Manual.WebHome||anchor="#HDownload"]]**
5 5  )))
6 6  
8 += 1 Safety =
9 +
7 7  Before installation, operation, maintenance, or inspection of this product, thoroughly read through and understand this manual and all of the associated manuals. Also, take care to handle the module properly and safely.
8 8  
9 9  = 2 Design =
... ... @@ -16,14 +16,6 @@
16 16  
17 17  = 3 Installation =
18 18  
19 -
20 -(% class="wikigeneratedid" id="H2.1PDFDownloadLink:" %)
21 -PDF Download Link:
22 -
23 -(((
24 -**[[Download>>doc:PLC Editor.1 User Manual.WebHome||anchor="#HDownload"]]**
25 -)))
26 -
27 27  Use the product within the generic environment specifications described in this manual. Never use the product in areas with excessive dust, oily smoke, conductive dusts, corrosive gas, flammable gas, vibration or impacts, or expose it to high temperature, condensation (extreme humidity), or rain, and strong wind. If the product is used in such conditions, electric shock, fire, malfunctions, deterioration or damage may occur.
28 28  
29 29  When drilling screw holes or wiring, make sure that cutting and wiring debris does not enter the ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.
... ... @@ -33,6 +33,7 @@
33 33  * To prevent temperature rise, do not install at the bottom, top and vertical. Be sure to install to wall horizontally as shown below.
34 34  * Please leave more than 50mm space between PLC CPU and other equipment or structures. Try to avoid high-voltage cables, high-voltage devices, and power equipment.
35 35  
31 +
36 36  (((
37 37  
38 38  )))
... ... @@ -153,17 +153,17 @@
153 153  (% class="table-bordered" %)
154 154  |(% style="width:74px" %)(((
155 155  (% style="text-align:center" %)
156 -[[image:Safety Precautions_html_912af9cfcc757eac.jpg||height="64" width="59"]]
152 +[[image:PLC Editor.5\.Hardware .2\.PLC Installation Manual.WebHome@Safety Precautions_html_912af9cfcc757eac.jpg||height="64" width="59"]]
157 157  
158 158  Warning
159 159  )))|(% style="width:1001px" %)(((
160 160  (% style="text-align:center" %)
161 -[[image:Safety Precautions_html_e02060a6a61850ed.jpg||height="192" width="552"]]
157 +[[image:PLC Editor.5\.Hardware .2\.PLC Installation Manual.WebHome@Safety Precautions_html_e02060a6a61850ed.jpg||height="192" width="552"]]
162 162  
163 163  It is very dangerous to switch the forward and reverse contactor at the same time. For such loads, the interlock must be set on the outside of the PLC besides the PLC internal program settings, as shown in the above picture.
164 164  )))
165 165  |(% style="width:74px" %)(((
166 -[[image:Safety Precautions_html_5f2ba223cca70793.jpg||height="54" width="60"]]
162 +[[image:PLC Editor.5\.Hardware .2\.PLC Installation Manual.WebHome@Safety Precautions_html_5f2ba223cca70793.jpg||height="54" width="60"]]
167 167  
168 168  Caution
169 169  )))|(% style="width:1001px" %)(((
... ... @@ -183,7 +183,7 @@
183 183  (((
184 184  (% class="table-bordered" %)
185 185  |(((
186 -[[image:Safety Precautions_html_662a1f3d56163ec3.jpg||height="39" width="35"]] Warning
182 +[[image:PLC Editor.5\.Hardware .2\.PLC Installation Manual.WebHome@Safety Precautions_html_662a1f3d56163ec3.jpg||height="39" width="35"]] Warning
187 187  )))
188 188  |(((
189 189  ✎ Do not touch any terminal while the PLC's power is on. Doing so may cause electric shock or malfunctions;
... ... @@ -197,7 +197,7 @@
197 197  (((
198 198  (% class="table-bordered" %)
199 199  |(((
200 -[[image:Safety Precautions_html_5f2ba223cca70793.jpg||height="32" width="35"]] Caution
196 +[[image:PLC Editor.5\.Hardware .2\.PLC Installation Manual.WebHome@Safety Precautions_html_5f2ba223cca70793.jpg||height="32" width="35"]] Caution
201 201  )))
202 202  |(((
203 203  ✎ Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions.