Changes for page 01 Precaution

Last modified by Joe on 2025/03/11 17:58

From version 35.1
edited by Stone Wu
on 2022/07/23 09:10
Change comment: Attachment moved from xwiki:PLC Editor.5\.Hardware .Wiring for 3V.WebHome.
To version 38.1
edited by Stone Wu
on 2022/07/23 09:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -139,7 +139,7 @@
139 139  (% style="text-align:center" %)
140 140  [[image:1635752425894-292.png||height="403" width="700" class="img-thumbnail"]]
141 141  
142 -= 1.4 Wiring =
142 += 4 Wiring =
143 143  
144 144  1. PLC signal input and output could not be passed on the same cable;
145 145  1. Signal input cable and output cable could not be in the same pipe with another power cable, could not be bundled together;
... ... @@ -171,8 +171,63 @@
171 171  1. Do not supply power to the [24+] and [24V] terminals (24V DC service power supply) on the main unit or extension units. Doing so may cause damage to the product;
172 172  1. Perform grounding to the grounding terminal on the main unit and extension units. Do not use common grounding with heavy electrical systems;
173 173  1. When there is less than 10ms instantaneous power failure, PLC will continue to work;
174 -1. When the power is cut off or the voltage is low for a long time, the PLC will stop working and the output will turn off. However, once the power is restored, the operation will restart automatically;
174 +1. When the power is cut off or the voltage is low for a long time, the PLC will stop working and the output will turn off. However, once the power is restored, the operation will restart automatically.
175 175  
176 +== PLC unit ==
177 +
178 +(% style="text-align:center" %)
179 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1635494139870-975.png||height="313" width="700" class="img-thumbnail"]]
180 +
181 +=== LX3V series PLC ===
182 +
183 +**LX3V-2416MT-A wiring demo**
184 +
185 +(% style="text-align:center" %)
186 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440579389-255.png||height="681" width="900" class="img-thumbnail"]]
187 +
188 +**LX3V-2416MT-D wiring demo**
189 +
190 +(% style="text-align:center" %)
191 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1635491295476-484.png||height="649" width="900" class="img-thumbnail"]]
192 +
193 +(% class="box infomessage" %)
194 +(((
195 +**✎Note:**
196 +
197 +1. AC power type,the L and N terminal is power supply terminal,the COM and 24V+ is transducer supply output.
198 +1. DC power type, the 24V+ and 24V- terminal is DC24v power supply terminal.
199 +)))
200 +
201 +== Communication interface definition ==
202 +
203 +(% style="text-align:center" %)
204 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622441093094-862.png||height="721" width="700" class="img-thumbnail"]]
205 +
206 +(% class="wikigeneratedid" id="H" %)
207 +(((
208 +== (% style="color:inherit; font-family:inherit; font-size:26px" %)LX3V series expansion module(%%) ==
209 +
210 +=== LX3V-4AD ===
211 +)))
212 +
213 +(% style="text-align:center" %)
214 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440720013-275.png||height="292" width="850" class="img-thumbnail"]]
215 +
216 +=== (% id="cke_bm_981S" style="display:none" %) [[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml11088\wps1.jpg]](%%)LX3V-4DA ===
217 +
218 +(% style="text-align:center" %)
219 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440784787-538.png||height="261" width="850" class="img-thumbnail"]]
220 +
221 +=== LX3V-4PT ===
222 +
223 +(% style="text-align:center" %)
224 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440838446-556.png||height="299" width="850" class="img-thumbnail"]]
225 +
226 +=== (% style="color:inherit; font-family:inherit" %)LX3V-4PT (%%) ===
227 +
228 +(% style="text-align:center" %)
229 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440911145-424.png]]
230 +
176 176  = 1.5 Startup and maintenance =
177 177  
178 178  (((
WECON LX3V Product Wiring Diagram_201911131244261_html_e9933a79b3dc46ba.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +77.9 KB
Content