Changes for page 01 Precaution
Last modified by Joe on 2025/03/11 17:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -139,7 +139,7 @@ 139 139 (% style="text-align:center" %) 140 140 [[image:1635752425894-292.png||height="403" width="700" class="img-thumbnail"]] 141 141 142 -= 1.4 Wiring =142 += 4 Wiring = 143 143 144 144 1. PLC signal input and output could not be passed on the same cable; 145 145 1. Signal input cable and output cable could not be in the same pipe with another power cable, could not be bundled together; ... ... @@ -171,8 +171,63 @@ 171 171 1. Do not supply power to the [24+] and [24V] terminals (24V DC service power supply) on the main unit or extension units. Doing so may cause damage to the product; 172 172 1. Perform grounding to the grounding terminal on the main unit and extension units. Do not use common grounding with heavy electrical systems; 173 173 1. When there is less than 10ms instantaneous power failure, PLC will continue to work; 174 -1. When the power is cut off or the voltage is low for a long time, the PLC will stop working and the output will turn off. However, once the power is restored, the operation will restart automatically ;174 +1. When the power is cut off or the voltage is low for a long time, the PLC will stop working and the output will turn off. However, once the power is restored, the operation will restart automatically. 175 175 176 +== PLC naming == 177 + 178 +(% style="text-align:center" %) 179 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1635494139870-975.png||height="313" width="700" class="img-thumbnail"]] 180 + 181 +=== LX3V series PLC === 182 + 183 +**LX3V-2416MT-A wiring demo** 184 + 185 +(% style="text-align:center" %) 186 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440579389-255.png||height="681" width="900" class="img-thumbnail"]] 187 + 188 +**LX3V-2416MT-D wiring demo** 189 + 190 +(% style="text-align:center" %) 191 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1635491295476-484.png||height="649" width="900" class="img-thumbnail"]] 192 + 193 +(% class="box infomessage" %) 194 +((( 195 +**✎Note:** 196 + 197 +1. AC power type,the L and N terminal is power supply terminal,the COM and 24V+ is transducer supply output. 198 +1. DC power type, the 24V+ and 24V- terminal is DC24v power supply terminal. 199 +))) 200 + 201 +== Communication interface == 202 + 203 +(% style="text-align:center" %) 204 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622441093094-862.png||height="721" width="700" class="img-thumbnail"]] 205 + 206 +(% class="wikigeneratedid" id="H" %) 207 +((( 208 +== (% style="color:inherit; font-family:inherit; font-size:26px" %)LX3V series expansion module(%%) == 209 + 210 +=== LX3V-4AD === 211 +))) 212 + 213 +(% style="text-align:center" %) 214 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440720013-275.png||height="292" width="850" class="img-thumbnail"]] 215 + 216 +=== (% id="cke_bm_981S" style="display:none" %) [[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml11088\wps1.jpg]](%%)LX3V-4DA === 217 + 218 +(% style="text-align:center" %) 219 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440784787-538.png||height="261" width="850" class="img-thumbnail"]] 220 + 221 +=== LX3V-4PT === 222 + 223 +(% style="text-align:center" %) 224 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440838446-556.png||height="299" width="850" class="img-thumbnail"]] 225 + 226 +=== (% style="color:inherit; font-family:inherit" %)LX3V-4PT (%%) === 227 + 228 +(% style="text-align:center" %) 229 +[[image:PLC Editor.LX3V programing manual.2\.PLC Installation Manual.WebHome@1622440911145-424.png]] 230 + 176 176 = 1.5 Startup and maintenance = 177 177 178 178 (((