142 -= 4 Wiring =
142 += 1.4 Wiring =
143 143  
144 144  1. PLC signal input and output could not be passed on the same cable;
145 145  1. Signal input cable and output cable could not be in the same pipe with another power cable, could not be bundled together;
... ... @@ -171,86 +171,35 @@
171 171  1. Do not supply power to the [24+] and [24V] terminals (24V DC service power supply) on the main unit or extension units. Doing so may cause damage to the product;
172 172  1. Perform grounding to the grounding terminal on the main unit and extension units. Do not use common grounding with heavy electrical systems;
173 173  1. When there is less than 10ms instantaneous power failure, PLC will continue to work;
174 -1. When the power is cut off or the voltage is low for a long time, the PLC will stop working and the output will turn off. However, once the power is restored, the operation will restart automatically.
174 +1. When the power is cut off or the voltage is low for a long time, the PLC will stop working and the output will turn off. However, once the power is restored, the operation will restart automatically;
175 175  
176 -== PLC naming ==
176 += 1.5 Startup and maintenance =
177 177  
178 -(% style="text-align:center" %)
179 -[[image:1635494139870-975.png||height="313" width="700" class="img-thumbnail"]]
180 -
181 -== LX3V series PLC ==
182 -
183 -**LX3V-2416MT-A wiring demo**
184 -
185 -(% style="text-align:center" %)
186 -[[image:1622440579389-255.png||height="681" width="900" class="img-thumbnail"]]
187 -
188 -**LX3V-2416MT-D wiring demo**
189 -
190 -(% style="text-align:center" %)
191 -[[image:1635491295476-484.png||height="649" width="900" class="img-thumbnail"]]
192 -
193 -(% class="box infomessage" %)
194 194  (((
195 -**✎Note:**
196 -
197 -1. AC power type,the L and N terminal is power supply terminal,the COM and 24V+ is transducer supply output.
198 -1. DC power type, the 24V+ and 24V- terminal is DC24v power supply terminal.
199 -)))
200 -
201 -== Communication interface ==
202 -
203 -(% style="text-align:center" %)
204 -[[image:1622441093094-862.png||height="721" width="700" class="img-thumbnail"]]
205 -
206 -(% class="wikigeneratedid" id="H" %)
207 -(((
208 -== (% style="color:inherit; font-family:inherit; font-size:26px" %)Expansion module(%%) ==
209 -
210 -=== LX3V-4AD ===
211 -)))
212 -
213 -(% style="text-align:center" %)
214 -[[image:1622440720013-275.png||height="292" width="850" class="img-thumbnail"]]
215 -
216 -=== (% id="cke_bm_981S" style="display:none" %)[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml11088\wps1.jpg]](%%)LX3V-4DA ===
217 -
218 -(% style="text-align:center" %)
219 -[[image:1622440784787-538.png||height="261" width="850" class="img-thumbnail"]]
220 -
221 -=== LX3V-4PT ===
222 -
223 -(% style="text-align:center" %)
224 -[[image:1622440838446-556.png||height="299" width="850" class="img-thumbnail"]]
225 -
226 -=== (% style="color:inherit; font-family:inherit" %)LX3V-4TC (%%) ===
227 -
228 -(% style="text-align:center" %)
229 -[[image:1622440911145-424.png]]
230 -
231 -= Startup and maintenance =
232 -
233 -(((
234 234  (% class="table-bordered" %)
235 -(% class="warning" %)|(((
180 +|(((
236 236  [[image:Safety Precautions_html_662a1f3d56163ec3.jpg||height="39" width="35"]] Warning
237 237  )))
238 238  |(((
239 -* Do not touch any terminal while the PLC's power is on. Doing so may cause electric shock or malfunctions;
240 -* Before cleaning or retightening terminals, cut off all phases of the power supply externally. Failure to do so may cause electric shock;
241 -* Before modifying or disrupting the program in operation or running the PLC, carefully read through this manual and the associated manuals and ensure the safety of the operation. An operation error may damage the machinery or cause accidents.
184 +✎ Do not touch any terminal while the PLC's power is on. Doing so may cause electric shock or malfunctions;
185 +
186 +✎ Before cleaning or retightening terminals, cut off all phases of the power supply externally. Failure to do so may cause electric shock;
187 +
188 +✎ Before modifying or disrupting the program in operation or running the PLC, carefully read through this manual and the associated manuals and ensure the safety of the operation. An operation error may damage the machinery or cause accidents.
242 242  )))
243 243  )))
244 244  
245 245  (((
246 246  (% class="table-bordered" %)
247 -(% class="warning" %)|(((
194 +|(((
248 248  [[image:Safety Precautions_html_5f2ba223cca70793.jpg||height="32" width="35"]] Caution
249 249  )))
250 250  |(((
251 -* Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions.
252 -* //For repair, contact WECON Technology Co.,//
253 -* Turn off the power to the PLC before connecting or disconnecting any extension cable. Failure to do so may cause equipment failures or malfunctions.
198 +✎ Do not disassemble or modify the PLC. Doing so may cause fire, equipment failures, or malfunctions.
199 +
200 +//For repair, contact WECON Technology Co.,//
201 +
202 +✎ Turn off the power to the PLC before connecting or disconnecting any extension cable. Failure to do so may cause equipment failures or malfunctions.