Content
... ... @@ -1,4 +1,4 @@
1 -= **3.1 General specifications** =
1 += **General specifications** =
2 2  
3 3  (% border="2" class="table-bordered" %)
4 4  |=(% style="width: 198px;" %)**Temperature**|=(% colspan="6" style="width: 877px;" %)Working temperature: 0~~55 ^^O^^C storage temperature: -20~~70^^ O^^C
... ... @@ -19,11 +19,11 @@
19 19  ※1
20 20  
21 21  (% style="text-align:center" %)
22 -[[image:4.Product specifications_html_3a894746e1e6cfe1.jpg||class="img-thumbnail" height="108" width="750"]]
22 +[[image:4.Product specifications_html_3a894746e1e6cfe1.jpg||height="108" width="750" class="img-thumbnail"]]
23 23  
24 -= **3.2 Electricity specification** =
24 += **Electricity specification** =
25 25  
26 -== **3.2.1 AC power type** ==
26 +== **AC power type** ==
27 27  
28 28  (% border="2" class="table-bordered" %)
29 29  |=**Model**|=LX3V-0806/1208/1212/1410/1412MX-A|=LX3V-1616/2416/2424/3624MX-A
... ... @@ -36,9 +36,12 @@
36 36  |**Power**|20W|50W
37 37  |**Sensor power supply**|DC 24V 70mA|DC 24V 70mA
38 38  
39 +(% class="box infomessage" %)
40 +(((
39 39  **✎Note:** The input current part (7mA / 1 point, 5mA / 1 point) is also included.
42 +)))
40 40  
41 -== **3.2.2 DC power type** ==
44 +== **DC power type** ==
42 42  
43 43  (((
44 44  (% border="2" class="table-bordered" %)
... ... @@ -50,7 +50,7 @@
50 50  |(% style="width:256px" %)**Impulse current**|(% style="width:818px" %)Less than 15A 1ms/AC 100V
51 51  |(% style="width:256px" %)**Power**|(% style="width:818px" %)Less than 30W(not include the power of the expansion module)
52 52  
53 -= **3.3 Input specification** =
56 += **Input specification** =
54 54  )))
55 55  
56 56  The specifications of the basic units of the LX series programmable controllers are shown in the table2-1 below:
... ... @@ -73,9 +73,12 @@
73 73   The diagram is NPN connection method, if S/S is connected to negative pole, X is connected to positive pole, that is PNP connection method.
74 74  )))
75 75  
79 +(% class="box infomessage" %)
80 +(((
76 76  **✎Note:** After X002 is 4.7KΩ.
82 +)))
77 77  
78 -= **3.4 Output specification** =
84 += **Output specification** =
79 79  
80 80  (% border="2" class="table-bordered" %)
81 81  |=(% colspan="2" %)**Output type**|=**Relay output**|=**Transistor output**
... ... @@ -103,24 +103,24 @@
103 103  Please connect the DC inductive load and the freewheeling diode in parallel. Otherwise, the contact life will be significouldtly reduced. Freewheeling diode reverse withstand voltage is 5 to 10 times the load voltage, the forward current value is higher than the load current.
104 104  
105 105  (% style="text-align:center" %)
106 -[[image:4.Product specifications_html_35e4656eabe3d9d5.jpg||class="img-thumbnail" height="209" width="650"]]
112 +[[image:4.Product specifications_html_35e4656eabe3d9d5.jpg||height="209" width="650" class="img-thumbnail"]]
107 107  
108 108  If the load is AC inductive, connect the load and surge absorber in parallel could reduce the noise.
109 109  
110 110  (% style="text-align:center" %)
111 -[[image:4.Product specifications_html_f49960fdc2323ec5.jpg||class="img-thumbnail" height="208" width="650"]]
117 +[[image:4.Product specifications_html_f49960fdc2323ec5.jpg||height="208" width="650" class="img-thumbnail"]]
112 112  
113 113  It is best to use the plc output contacts on the same phase as Figure 2-3 shown below.
114 114  
115 115  (% style="text-align:center" %)
116 -[[image:4.Product specifications_html_813dbe36c8ac8144.jpg||class="img-thumbnail" height="272" width="600"]]
122 +[[image:4.Product specifications_html_813dbe36c8ac8144.jpg||height="272" width="600" class="img-thumbnail"]]
117 117  
118 118  It is very dangerous to connect the FWD and REV contact at the same time. In addition to adding the interlocking control of the program in the plc, there also should be an interlock outside the PLC.
119 119  
120 120  (% style="text-align:center" %)
121 -[[image:4.Product specifications_html_6d23c8052386163.jpg||class="img-thumbnail" height="194" width="650"]]
127 +[[image:4.Product specifications_html_6d23c8052386163.jpg||height="194" width="650" class="img-thumbnail"]]
122 122  
123 -= **3.5 Product naming rule** =
129 += **Product naming rule** =
124 124  
125 125  The model of the plc could be found on the label on the side of the product.
126 126  
... ... @@ -127,7 +127,7 @@
127 127  **[The basic unit's model name constitutes]**
128 128  
129 129  (% style="text-align:center" %)
130 -[[image:4.Product specifications_html_85dc603ba603e964.jpg||class="img-thumbnail" height="135" width="600"]]
136 +[[image:4.Product specifications_html_85dc603ba603e964.jpg||height="135" width="600" class="img-thumbnail"]]
131 131  
132 132  The meaning of 1~~6 is as below.
133 133