Changes for page 03 Specifications

Last modified by Mora Zhou on 2023/12/22 10:48

From version 3.1
edited by Mora Zhou
on 2023/12/22 10:48
Change comment: There is no comment for this version
To version 2.4
edited by Leo Wei
on 2022/07/28 11:26
Change comment: Update document after refactoring.

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.admin
Content
... ... @@ -1,4 +1,4 @@
1 -= **General specifications** =
1 += **3.1 General specifications** =
2 2  
3 3  (% border="2" class="table-bordered" %)
4 4  |=(% style="width: 198px;" %)**Temperature**|=(% colspan="6" style="width: 877px;" %)Working temperature: 0~~55 ^^O^^C storage temperature: -20~~70^^ O^^C
... ... @@ -19,11 +19,11 @@
19 19  ※1
20 20  
21 21  (% style="text-align:center" %)
22 -[[image:4.Product specifications_html_3a894746e1e6cfe1.jpg||height="108" width="750" class="img-thumbnail"]]
22 +[[image:4.Product specifications_html_3a894746e1e6cfe1.jpg||class="img-thumbnail" height="108" width="750"]]
23 23  
24 -= **Electricity specification** =
24 += **3.2 Electricity specification** =
25 25  
26 -== **AC power type** ==
26 +== **3.2.1 AC power type** ==
27 27  
28 28  (% border="2" class="table-bordered" %)
29 29  |=**Model**|=LX3V-0806/1208/1212/1410/1412MX-A|=LX3V-1616/2416/2424/3624MX-A
... ... @@ -36,12 +36,9 @@
36 36  |**Power**|20W|50W
37 37  |**Sensor power supply**|DC 24V 70mA|DC 24V 70mA
38 38  
39 -(% class="box infomessage" %)
40 -(((
41 41  **✎Note:** The input current part (7mA / 1 point, 5mA / 1 point) is also included.
42 -)))
43 43  
44 -== **DC power type** ==
41 +== **3.2.2 DC power type** ==
45 45  
46 46  (((
47 47  (% border="2" class="table-bordered" %)
... ... @@ -53,7 +53,7 @@
53 53  |(% style="width:256px" %)**Impulse current**|(% style="width:818px" %)Less than 15A 1ms/AC 100V
54 54  |(% style="width:256px" %)**Power**|(% style="width:818px" %)Less than 30W(not include the power of the expansion module)
55 55  
56 -= **Input specification** =
53 += **3.3 Input specification** =
57 57  )))
58 58  
59 59  The specifications of the basic units of the LX series programmable controllers are shown in the table2-1 below:
... ... @@ -76,12 +76,9 @@
76 76   The diagram is NPN connection method, if S/S is connected to negative pole, X is connected to positive pole, that is PNP connection method.
77 77  )))
78 78  
79 -(% class="box infomessage" %)
80 -(((
81 81  **✎Note:** After X002 is 4.7KΩ.
82 -)))
83 83  
84 -= **Output specification** =
78 += **3.4 Output specification** =
85 85  
86 86  (% border="2" class="table-bordered" %)
87 87  |=(% colspan="2" %)**Output type**|=**Relay output**|=**Transistor output**
... ... @@ -109,24 +109,24 @@
109 109  Please connect the DC inductive load and the freewheeling diode in parallel. Otherwise, the contact life will be significouldtly reduced. Freewheeling diode reverse withstand voltage is 5 to 10 times the load voltage, the forward current value is higher than the load current.
110 110  
111 111  (% style="text-align:center" %)
112 -[[image:4.Product specifications_html_35e4656eabe3d9d5.jpg||height="209" width="650" class="img-thumbnail"]]
106 +[[image:4.Product specifications_html_35e4656eabe3d9d5.jpg||class="img-thumbnail" height="209" width="650"]]
113 113  
114 114  If the load is AC inductive, connect the load and surge absorber in parallel could reduce the noise.
115 115  
116 116  (% style="text-align:center" %)
117 -[[image:4.Product specifications_html_f49960fdc2323ec5.jpg||height="208" width="650" class="img-thumbnail"]]
111 +[[image:4.Product specifications_html_f49960fdc2323ec5.jpg||class="img-thumbnail" height="208" width="650"]]
118 118  
119 119  It is best to use the plc output contacts on the same phase as Figure 2-3 shown below.
120 120  
121 121  (% style="text-align:center" %)
122 -[[image:4.Product specifications_html_813dbe36c8ac8144.jpg||height="272" width="600" class="img-thumbnail"]]
116 +[[image:4.Product specifications_html_813dbe36c8ac8144.jpg||class="img-thumbnail" height="272" width="600"]]
123 123  
124 124  It is very dangerous to connect the FWD and REV contact at the same time. In addition to adding the interlocking control of the program in the plc, there also should be an interlock outside the PLC.
125 125  
126 126  (% style="text-align:center" %)
127 -[[image:4.Product specifications_html_6d23c8052386163.jpg||height="194" width="650" class="img-thumbnail"]]
121 +[[image:4.Product specifications_html_6d23c8052386163.jpg||class="img-thumbnail" height="194" width="650"]]
128 128  
129 -= **Product naming rule** =
123 += **3.5 Product naming rule** =
130 130  
131 131  The model of the plc could be found on the label on the side of the product.
132 132  
... ... @@ -133,7 +133,7 @@
133 133  **[The basic unit's model name constitutes]**
134 134  
135 135  (% style="text-align:center" %)
136 -[[image:4.Product specifications_html_85dc603ba603e964.jpg||height="135" width="600" class="img-thumbnail"]]
130 +[[image:4.Product specifications_html_85dc603ba603e964.jpg||class="img-thumbnail" height="135" width="600"]]
137 137  
138 138  The meaning of 1~~6 is as below.
139 139