Changes for page 09 Electronic cam

Last modified by Devin Chen on 2025/01/09 11:57

From version 7.1
edited by Stone Wu
on 2022/09/26 12:02
Change comment: There is no comment for this version
To version 6.1
edited by Stone Wu
on 2022/09/26 11:24
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -566,15 +566,17 @@
566 566  **(1) Parameters**
567 567  
568 568  (% class="table-bordered" %)
569 -|**Parameter**|(% style="width:527px" %)**Content**|(% style="width:226px" %)**Range**|(% style="width:143px" %)**Data type**|**Data type (label)**
570 -|(s1)|(% style="width:527px" %)Specify to receive the input pulse of the master axis|(% style="width:226px" %)(((
571 --2147483648 to +2147483647
572 -)))|(% style="width:143px" %)Signed BIN 32 bit|ANY32
573 -|(s2)|(% style="width:527px" %)Specify the data buffer area of the ECAM instruction|(% style="width:226px" %) |(% style="width:143px" %)Form|LIST
574 -|(s3)|(% style="width:527px" %)The external start signal of ECAM needs to be enabled in the data buffer area to be effective.|(% style="width:226px" %)X/M/S/D.b|(% style="width:143px" %)Signed BIN 32 bit|ANY32
575 -|(d1)|(% style="width:527px" %)Specify pulse output axis|(% style="width:226px" %)Y0 to Y7|(% style="width:143px" %)Bit|ANY_BOOL
576 -|(d2)|(% style="width:527px" %)Specify direction output axis|(% style="width:226px" %)Y/M/S/D.b|(% style="width:143px" %)Bit|ANY_BOOL
569 +|**Parameter**|(% style="width:812px" %)**Content**|(% style="width:185px" %)**Range**|**Data type**|**Data type (label)**
570 +|(s1)|(% style="width:812px" %)Specify to receive the input pulse of the master axis|(% style="width:185px" %)(((
571 +-2147483648 to
577 577  
573 ++2147483647
574 +)))|Signed BIN 32 bit|ANY32
575 +|(s2)|(% style="width:812px" %)Specify the data buffer area of the ECAM instruction|(% style="width:185px" %) |Form|LIST
576 +|(s3)|(% style="width:812px" %)The external start signal of ECAM needs to be enabled in the data buffer area to be effective.|(% style="width:185px" %)X/M/S/D.b|Signed BIN 32 bit|ANY32
577 +|(d1)|(% style="width:812px" %)Specify pulse output axis|(% style="width:185px" %)Y0 to Y7|Bit|ANY_BOOL
578 +|(d2)|(% style="width:812px" %)Specify direction output axis|(% style="width:185px" %)Y/M/S/D.b|Bit|ANY_BOOL
579 +
578 578  **{{id name="_Toc9293"/}}Device used:**
579 579  
580 580  (% class="table-bordered" %)
... ... @@ -666,7 +666,7 @@
666 666  ✎When a cycle is completed, ECAM cycle completion flag address 1-bit1 turns ON, and the user clears the completion flag by itself, and then continues to judge the next cycle.
667 667  
668 668  (% style="text-align:center" %)
669 -[[image:image-20220926115030-2.jpeg||class="img-thumbnail"]]
671 +[[image:09_html_230c69b0429b0c.gif||height="259" width="800" class="img-thumbnail"]]
670 670  
671 671  {{id name="_Toc18782"/}}2) Periodic ECAM stop
672 672  
... ... @@ -676,7 +676,8 @@
676 676  
677 677  ✎When the periodic ECAM is operating, the system receives the completion stop flag ((address 4-bit1), the periodic ECAM will continue until the current table is executed, the slave axis will stop operating, as shown in the figure below. If you want to start the periodic cam again, you need to write 0 to address 5 and keep it more than 100us, and then you can start the periodic cam through address 5 again.
678 678  
679 -[[image:image-20220926115519-3.jpeg]]
681 +(% style="text-align:center" %)
682 +[[image:09_html_cfb2abe40245003c.gif||height="373" width="900" class="img-thumbnail"]]
680 680  
681 681  {{id name="_Toc31992"/}}3) Example description
682 682  
... ... @@ -726,7 +726,7 @@
726 726  1. Sync signal terminal output.
727 727  
728 728  (% style="text-align:center" %)
729 -[[image:image-20220926120124-4.jpeg]]
732 +[[image:09_html_8efdb40d8fd3ece6.gif||height="357" width="900" class="img-thumbnail"]]
730 730  
731 731  2) Aperiodic electronic cam stop
732 732  
... ... @@ -737,7 +737,7 @@
737 737   2. When the aperiodic ECAM is running, address 4-BIT1=1 (stop after the current cycle is completed), the aperiodic ECAM will continue to run through the table and then the slave axis will stop operating, as shown in the figure below.
738 738  
739 739  (% style="text-align:center" %)
740 -[[image:image-20220926120303-5.jpeg]]
743 +[[image:09_html_93e0a854c1e8db80.gif||height="333" width="800" class="img-thumbnail"]]
741 741  
742 742  3) Example explanation
743 743  
... ... @@ -765,7 +765,7 @@
765 765  [PLC program]
766 766  
767 767  (% style="text-align:center" %)
768 -[[image:image-20220926114246-1.jpeg]]
771 +[[image:09_html_d46ee9de94f51e8b.jpg||height="983" width="500" class="img-thumbnail"]]
769 769  
770 770  **{{id name="_电子凸轮功能寄存器"/}}Electronic cam function register**
771 771  
image-20220926114246-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -64.2 KB
Content
image-20220926115030-2.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -110.6 KB
Content
image-20220926115519-3.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -149.2 KB
Content
image-20220926120124-4.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -164.6 KB
Content
image-20220926120303-5.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -152.7 KB
Content