@@ -1,35 +1,28 @@ |
1 |
|
-= 1 Index = |
|
1 |
+= 1. Protocol = |
2 |
2 |
|
3 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Index.zip]] |
|
3 |
+(% class="table-bordered" %) |
|
4 |
+|(% style="width:332px" %)**Name**|(% style="width:599px" %)**Explanation**|(% style="width:145px" %)**Download ** |
|
5 |
+|(% style="width:332px" %)1. Modbus TCP communication|(% style="width:599px" %)Setting of PLC as server/client|(% style="width:145px" %)[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91ModbusTCP%20Protocol.zip]] |
|
6 |
+|(% style="width:332px" %)2. Modbus RTU communication|(% style="width:599px" %)Setting of PLC as master/slave|(% style="width:145px" %)[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Modbus%20Communication.zip]] |
4 |
4 |
|
5 |
|
-= 2 Modbus Communication = |
|
8 |
+= 2. Instruction = |
6 |
6 |
|
7 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Modbus%20Communication.zip]] |
8 |
8 |
|
9 |
|
-= **3 Modbus Polling** = |
|
11 |
+(% class="table-bordered" %) |
|
12 |
+|(% style="width:332px" %)**Name**|(% style="width:601px" %)**Explanation**|(% style="width:143px" %)**Download ** |
|
13 |
+|(% style="width:332px" %)1. Indirect addressing|(% style="width:601px" %)Programming for indirect addressing|(% style="width:143px" %)[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Index.zip]] |
|
14 |
+|(% style="width:332px" %)2. Clock calculation|(% style="width:601px" %)Read, write and compare operations of PLC clock|(% style="width:143px" %)[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Clock%20Calculation.zip]] |
|
15 |
+|(% style="width:332px" %)3. High-speed pulse output|(% style="width:601px" %)Simple example of high-speed pulse output instruction|(% style="width:143px" %)[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91High-Speed%20Pulse%20Output.zip]] |
|
16 |
+|(% style="width:332px" %)4. Step instruction|(% style="width:601px" %)Example of step instruction|(% style="width:143px" %)[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Step%20instruction.zip]] |
|
17 |
+|(% style="width:332px" %)5. Exponential calculation|(% style="width:601px" %)Exponential operation through instruction conversion|(% style="width:143px" %)[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Exponential%20Calculation.zip]] |
10 |
10 |
|
11 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Modbus%20Polling.zip]] |
|
19 |
+= 3. Application = |
12 |
12 |
|
13 |
|
-= 4 ModbusTCP Protocol = |
14 |
|
- |
15 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91ModbusTCP%20Protocolo.zip]] |
16 |
|
- |
17 |
|
-= **5 Clock Calculation** = |
18 |
|
- |
19 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Clock%20Calculation.zip]] |
20 |
|
- |
21 |
|
-= **6 Flow Led** = |
22 |
|
- |
23 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Flow%20Led.zip]] |
24 |
|
- |
25 |
|
-= 7 Limit Alarm = |
26 |
|
- |
27 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Limit%20Alarm.zip]] |
28 |
|
- |
29 |
|
-= **8 Traffic Light** = |
30 |
|
- |
31 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Traffic%20Light.zip]] |
32 |
|
- |
33 |
|
-= **9. PID Control** = |
34 |
|
- |
35 |
|
-[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91PID%20Control.zip]] |
|
21 |
+(% class="table-bordered" %) |
|
22 |
+|**Name**|**Explanation**|**Download ** |
|
23 |
+|1.** **Modbus polling|Polling operation of a single serial port|[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Modbus%20Polling.zip]] |
|
24 |
+|2. Flow Led|Lights a certain number of lights in sequence|[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Flow%20Led.zip]] |
|
25 |
+|3.** **Traffic light|Crossroad traffic light case|[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Traffic%20Light.zip]] |
|
26 |
+|4. Limit alarm|Stop output when the limit is reached|[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Limit%20Alarm.zip]] |
|
27 |
+|5. PID control|PID control heating temperature|[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91PID%20Control.zip]] |
|
28 |
+|6. Data collection and recording|Periodically collect data and record it in the specified register|[[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/demo/%E3%80%90PLC-5V%E3%80%91Data%20Collection%20and%20Recording.zip]] |