Changes for page 03 Software

Last modified by Jim on 2025/01/10 15:20

From version 14.1
edited by Stone Wu
on 2022/08/09 09:11
Change comment: There is no comment for this version
To version 28.1
edited by Jim
on 2024/02/29 10:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Jim
Content
... ... @@ -1,25 +1,44 @@
1 -= **1 Wecon PLC Editor2** =
1 +|=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
2 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.66(20231113)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.66.23111301.zip]]|(% style="width:652px" %)(((
3 +Software Update:
2 2  
3 -(% class="wikigeneratedid" %)
4 -Applicable to LX5S / LX5V series
5 +* Optimize 6V ladder diagram loading speed;
6 +* Optimize communication interface stuck problem;
7 +* Optimize the response time of the software when opening a large project;
8 +* Some bug fixes;
5 5  
6 -== Ver2.1.203 ==
10 +New features
7 7  
8 -Update time: 2022/08/08
12 +* 5V PWM instructions increased to 16 channels (8*1μs + 8*100μs);
13 +* Added 6V global variable MODBUS address mapping;
14 +* The maximum array length limit of 6V is increased from 49 to 99;
15 +* Added 6V comment editing function;
16 +* Add a new array using variables as subscripts.
17 +)))
9 9  
10 -* [[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/Wecon%20PLC%20Editor2%20setup.exe]]
19 +|=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
20 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.247|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.47.23090402.zip]]|(% style="width:652px" %)(((
21 +Software Update:
11 11  
23 +* Added 6V pulse axis function;
24 +* Added 6V axis group function;
25 +* Added 6V function to read PLC CPU temperature and occupancy rate;
26 +* Added 5V PLC identification code function;
27 +* Added LX1V model.
28 +)))
29 +
30 +|=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
31 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.1.203|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20PLC%20Editor2%20setup%202.1.203_R1_0729.zip]]|(% style="width:652px" %)(((
12 12  Software Update:
13 13  
14 -* Applicable to LX5S / LX5V series
15 -* Add monitor edit function
16 -* Add ethernet communication function(Model with -N)
17 -* Add IP search function(Model with -N)
18 -* Add PLCLINK function (Optimize and upgrade the previous 3V N:N protocol)
19 -* Add batch search and replace function of soft components
20 -* Add 3V software interface in 5V software
21 -* Support COM1 user define protocol
22 -* Add DSZR/BCC/MAX/MIN instruction.
34 +* Add monitor edit function;
35 +* Add ethernet communication function(Model with -N);
36 +* Add IP search function(Model with -N);
37 +* Add PLCLINK function (Optimize and upgrade the previous 3V N:N protocol);
38 +* Add batch search and replace function of soft components;
39 +* Add 3V software interface in 5V software;
40 +* Support COM1 user define protocol;
41 +* Add DSZR/BCC/MAX/MIN instruction;
23 23  * New 5V PLC firmware: V2.013 Update:
24 24  * Add multiple origin regression instruction functions of DSZR;
25 25  * Support COM1 user define protocol;
... ... @@ -29,6 +29,5 @@
29 29  * Add the hardware configuration table function.
30 30  * Add BCC/MAX/MIN instruction;
31 31  * Add the function of direction delay of interpolation instruction;
32 -* Add monitor edit function
33 -
34 -
51 +* Add monitor edit function.
52 +)))