Changes for page 03 Software

Last modified by Jim on 2025/01/10 15:20

From version 14.1
edited by Stone Wu
on 2022/08/09 09:11
Change comment: There is no comment for this version
To version 30.1
edited by Jim
on 2024/02/29 10:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Jim
Content
... ... @@ -1,34 +1,45 @@
1 -= **1 Wecon PLC Editor2** =
1 +|=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
2 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.118(20240103)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.118.24010301.zip]]|(% style="width:652px" %)(((
3 +Software Update:
2 2  
3 -(% class="wikigeneratedid" %)
4 -Applicable to LX5S / LX5V series
5 +* Fixed 5S high-speed input problem;
6 +* Fixed the problem that the conversion failed when downloading some 6V ladder diagrams
5 5  
6 -== Ver2.1.203 ==
8 +New features
7 7  
8 -Update time: 2022/08/08
10 +* Add LX6S model;
11 +* Support EtherCAT remote IO module;
12 +* Support LX6S axis group and local pulse axis;
13 +* Supporrt LX6 series 4AD/4DA module
14 +)))
9 9  
10 -* [[Download>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/Wecon%20PLC%20Editor2%20setup.exe]]
16 +|=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
17 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.66(20231113)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.66.23111301.zip]]|(% style="width:652px" %)(((
18 +Software Update:
11 11  
20 +* Optimize 6V ladder diagram loading speed;
21 +* Optimize communication interface stuck problem;
22 +* Optimize the response time of the software when opening a large project;
23 +* Some bug fixes;
24 +
25 +New features
26 +
27 +* 5V PWM instructions increased to 16 channels (8*1μs + 8*100μs);
28 +* Added 6V global variable MODBUS address mapping;
29 +* The maximum array length limit of 6V is increased from 49 to 99;
30 +* Added 6V comment editing function;
31 +* Add a new array using variables as subscripts.
32 +)))
33 +
34 +|=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
35 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.247|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.47.23090402.zip]]|(% style="width:652px" %)(((
12 12  Software Update:
13 13  
14 -* Applicable to LX5S / LX5V series
15 -* Add monitor edit function
16 -* Add ethernet communication function(Model with -N)
17 -* Add IP search function(Model with -N)
18 -* Add PLCLINK function (Optimize and upgrade the previous 3V N:N protocol)
19 -* Add batch search and replace function of soft components
20 -* Add 3V software interface in 5V software
21 -* Support COM1 user define protocol
22 -* Add DSZR/BCC/MAX/MIN instruction.
23 -* New 5V PLC firmware: V2.013 Update:
24 -* Add multiple origin regression instruction functions of DSZR;
25 -* Support COM1 user define protocol;
26 -* Add PLCLINK function;
27 -* Add acceleration and deceleration (trapezoidal and S-shaped) time division function;
28 -* Add spiral interpolation instruction;
29 -* Add the hardware configuration table function.
30 -* Add BCC/MAX/MIN instruction;
31 -* Add the function of direction delay of interpolation instruction;
32 -* Add monitor edit function
38 +* Added 6V pulse axis function;
39 +* Added 6V axis group function;
40 +* Added 6V function to read PLC CPU temperature and occupancy rate;
41 +* Added 5V PLC identification code function;
42 +* Added LX1V model.
43 +)))
33 33  
34 34